Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effect of sensory substitution on suture-manipulation forces for robotic surgical systems

Open access
Kitagawa, Masaya, Dokko, Daniell, Okamura, Allison M., Yuh, David D.·2005·The Journal of Thoracic and Cardiovascular Surgery

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jtcvs.2004.05.029

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 22

  1. Yoshino, 2001, Thoracoscopic thymectomy with the da Vinci computer-enhanced surgical system, J Thorac Cardiovasc Surg., 122, 783, 10.1067/mtc.2001.115231 · doi:10.1067/mtc.2001.115231
  2. Shennib, 1998, Computer-assisted telemanipulation: an enabling technology for endoscopic coronary artery bypass, Ann Thorac Surg., 66, 1060, 10.1016/S0003-4975(98)00659-6 · DOI
  3. Kappert, 2000, Closed-chest coronary artery surgery on the beating heart with the use of a robotic system, J Thorac Cardiovasc Surg., 120, 809, 10.1067/mtc.2000.109543 · doi:10.1067/mtc.2000.109543
  4. Boyd, 2000, Closed-chest coronary artery bypass grafting on the beating heart with the use of a computer-enhanced surgical robotic system, J Thorac Cardiovasc Surg., 120, 807, 10.1067/mtc.2000.109541 · doi:10.1067/mtc.2000.109541
  5. Chitwood, 2000, Minimally invasive videoscopic mitral valve surgery: the current role of surgical robotics, J Card Surg., 15, 61, 10.1111/j.1540-8191.2000.tb00445.x · doi:10.1111/j.1540-8191.2000.tb00445.x
  6. Felger, 2002, The evolution of and early experience with robot-assisted mitral valve surgery, Surg Laparosc Endosc Percutan Tech., 12, 58, 10.1097/00129689-200202000-00010 · doi:10.1097/00129689-200202000-00010
  7. Reichenspurner, 1998, 3D-video- and robot-assisted minimally invasive ASD closure using the Port-Access techniques, Heart Surg Forum., 1, 104
  8. DeRose, 2003, Robotically assisted left ventricular epicardial lead implantation for biventricular pacing, J Am Coll Cardiol., 41, 1414, 10.1016/S0735-1097(03)00252-3 · DOI
  9. Kitagawa M, Okamura AM, Bethea BT, Gott VL, Baumgartner WA. Analysis of suture manipulation forces for teleoperation with force feedback. In: Dohi T, Kikinis R, editors. Lecture Notes in Computer Science, vol 2488. Proceedings of the Fifth International Conference on Medical Image Computing and Computer Assisted Intervention—MICCAI 2002 Sep 26-29; Tokyo, Japan. Heidelberg, Springer-Verlag; p. 155-62. · DOI
  10. Massimino, 1995, Improved force perception through sensory substitution, Control Eng Pract., 3, 215, 10.1016/0967-0661(94)00079-V · DOI
  11. Debus T, Becker T, Dupont P, Jang T, Howe R. Telemanipulator and Telepresence Technology VIII Conference, vol 4570. Proceedings of SPIE (The International Society for Optical Engineering), Newton (MA), 2001 Oct 28; Bellingham (WA), SPIE. · DOI
  12. Massimino MJ, Sheridan TB. Sensory substitution for force feedback in teleoperation. IFAC Symposia Series; 1992 Jun 9-11; Hague, The Netherlands. Tarrytown (NY), Pergamon Press; 1993. · DOI · Paper page
  13. Richard P, Coiffet P. Human perceptual issues in virtual environments: sensory substitution and information redundancy. In: Robot and Human Communication. Proceedings of the IEEE International Workshop; Tokyo, 1995 Jul 5-7; Piscataway (NJ), IEEE; 1995. · DOI
  14. Schneeberger, 2001, An overview of the Intuitive system: the surgeon's perspective, Operative Techniques Thorac Cardiovasc Surg., 6, 170, 10.1053/otct.2001.26962 · doi:10.1053/otct.2001.26962
  15. Czibik, 2002, Robotic cardiac surgery: present and future applications, J Cardiothorac Vasc Anesth., 16, 495, 10.1053/jcan.2002.125129 · doi:10.1053/jcan.2002.125129
  16. Damiano, 2000, Endoscopic coronary artery bypass grafting—the first steps on a long journey, J Thorac Cardiovasc Surg., 120, 806, 10.1067/mtc.2000.109542 · doi:10.1067/mtc.2000.109542
  17. Grossi, 2000, Case report of robotic instrument-enhanced mitral valve surgery, J Thorac Cardiovasc Surg., 120, 1169, 10.1067/mtc.2000.110176 · doi:10.1067/mtc.2000.110176
  18. Autschbach, 2000, The Leipzig experience with robotic valve surgery, J Card Surg., 15, 82, 10.1111/j.1540-8191.2000.tb00447.x · doi:10.1111/j.1540-8191.2000.tb00447.x
  19. Chitwood, 2003, Robotic mitral valve surgery, Heart Surg Forum., 6, 106
  20. Dennerlein, 2001, Haptic force-feedback devices for the office computer: performance and musculoskeletal loading issues, Hum Factors., 43, 278, 10.1518/001872001775900850 · DOI
  21. Hannaford, 1991, Performance evaluation of a six-axis generalized force-reflecting teleoperator, IEEE Trans Systems Man Cybernetics., 21(3), 620, 10.1109/21.97455 · DOI · Paper page
  22. Rosen, 1999, Force controlled and teleoperated endoscopic grasper for minimally invasive surgery—experimental performance evaluation, IEEE Trans Biomed Eng., 46, 1212, 10.1109/10.790498 · DOI · Paper page

Cited by

See all 278

Metadata

Authors
Kitagawa, M., Dokko, D., Okamura, A. M., & Yuh, D. D.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
2005-01
Volume
129
Issue
1
Pages
151-158
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2133041452
Cited by
278
References
1
FWCI
21.39
Type
journal article
Language
en
Open access
bronze
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. https://app.cochat.ai/papers/10.1016/j.jtcvs.2004.05.029
The paper
Kitagawa, M., Dokko, D., Okamura, A. M., & Yuh, D. D. (2005). Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2004.05.029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.