The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Video-assisted bilateral pulmonary vein isolation and left atrial appendage exclusion for atrial fibrillation
Open accessAbstract
Objective Pulmonary vein isolation is curative in selected patients with atrial fibrillation. The objective of this study was to assess the feasibility and safety (midterm results) of video-assisted thoracoscopic epicardial pulmonary vein isolation.Methods Twenty-seven patients (22 male patients) with atrial fibrillation (18 paroxysmal, 4 persistent, and 5 permanent; average age, 57 years) underwent bilateral video-assisted thoracoscopic off-pump epicardial pulmonary vein isolation and exclusion of the left atrial appendage. All patients had had unsuccessful drug therapy or were intolerant to antiarrhythmic drug therapy or were intolerant to warfarin. The approach included two 10-mm ports and one 5-cm working port (non-rib spreading) bilaterally. Pulmonary vein isolation was achieved bilaterally by using a bipolar radiofrequency device. The left atrial appendage was excised with a surgical stapler.Results Bilateral pulmonary vein isolation and left atrial appendage excision was performed successfully in all patients. There were no conversions to sternotomy or thoracotomy. All patients were extubated in the operating room. Postoperative complications in 3 patients were minor and resolved within 48 hours. One morbidly obese patient had more serious complications related to comorbid conditions. Average postoperative follow-up is approximately 6 months (173.6 days). Twenty-three patients have been followed up for greater than 3 months, and 21 of these patients are free of atrial fibrillation (91.3%). The results of magnetic resonance angiography were normal (no pulmonary vein stenosis) in 12 of 12 patients evaluated 3 to 6 months postoperatively.Conclusions Bilateral video-assisted thoracoscopic pulmonary vein isolation with excision of the left atrial appendage is feasible and safe and offers a promising, new, minimally invasive, beating-heart approach for curative surgical treatment of atrial fibrillation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Minimally invasive epicardial ablation surgery for the treatment of stand-alone AF was reported a decade ago.1035”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [1035]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Go, A. S., Hylek, E. M., Phillips, K. A., Chang, Y., Henault, L. E., Selby, J. V., & Singer, D. E. (2001) · JAMA · doi:10.1001/jama.285.18.2370 · Cited by 6,205
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575
Pappone, C., Santinelli, V., Manguso, F., Vicedomini, G., Gugliotta, F., Augello, G., Mazzone, P., Tortoriello, V., Landoni, G., Zangrillo, A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000112641.16340.c7 · Cited by 1,018
Dries, D. L., Exner, D., Gersh, B., DOMANSKI, M. J., Waclawiw, M. A., & Stevenson, L. W. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00297-6 · Cited by 967
Catheter Ablation for Paroxysmal Atrial Fibrillation
Oral, H., Scharf, C., Chugh, A., HALL, B. W., Cheung, P. W., Good, E. D., Veerareddy, S., Pelosi, F., & Morady, F. (2003) · Circulation · doi:10.1161/01.cir.0000095796.45180.88 · Cited by 896
Pappone, C., Oral, H., Santinelli, V., Vicedomini, G., Lang, C., Manguso, F., Torracca, L., Benussi, S., Alfieri, O., Hong, R., et al. (2004) · Circulation · doi:10.1161/01.cir.0000131866.44650.46 · Cited by 871
Ouyang, F. O., Antz, M., Ernst, S., Hachiya, H., Mavrakis, H. E., Deger, F. T., Schaumann, A., Chun, K. R. J., Falk, P., Hennig, D., et al. (2004) · Circulation · doi:10.1161/01.cir.0000151289.73085.36 · Cited by 793
Antiarrhythmic drug therapy and cardiac mortality in atrial fibrillation
Flaker, G. C., Blackshear, J. L., McBride, R., Kronmal, R. A., Halperin, J. L., & Hart, R. G. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90003-6 · Cited by 633
Cappato, R., Negroni, S., Pecora, D., Bentivegna, S., Lupo, P. P., Carolei, A., Esposito, C., Furlanello, F., & AMBROGGI, L. D. (2003) · Circulation · doi:10.1161/01.cir.0000091081.19465.f1 · Cited by 406
Circular mapping and ablation of thepulmonary vein for treatment of atrial fibrillation
MARROUCHE, N. F., Dresing, T., Cole, C. R., Bash, D., Saad, E., Balaban, K., PAVIA, S. V., Schweikert, R. A., Saliba, W. I., Abdul-Karim, A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01972-1 · Cited by 399
Pulmonary Vein Stenosis After Radiofrequency Ablation of Atrial Fibrillation
Saad, E., Rossillo, A., Saad, C. P., Martin, D. O., Bhargava, M., Erciyes, D., Bash, D., Williams‐Andrews, M., Beheiry, S., Marrouche, N. F., et al. (2003) · Circulation · doi:10.1161/01.cir.0000104569.96907.7f · Cited by 358
Gaynor, S. L., Diodato, M. D., Prasad, S. M., Ishii, Y., Schuessler, R. B., Bailey, M. S., Damiano, N. R., Bloch, J. B., Moon, M. R., & Damiano, R. J. (2004) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.02.044 · Cited by 329
Left Atrial–Esophageal Fistula Following Radiofrequency Catheter Ablation of Atrial Fibrillation
Scanavacca, M., d’Ávila, A., Parga, J. R., & Sosa, E. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04083.x · Cited by 313
Esophageal perforation during left atrial radiofrequency ablation: Is the risk too high?
Doll, N., Borger, M. A., Fabricius, A., Stephan, S., Gummert, J. F., Mohr, F. W., Hauss, J., Kottkamp, H., & Hindricks, G. (2003) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.165 · Cited by 312
Current Status of the Maze Procedure for the Treatment of Atrial Fibrillation
Cox, J. L., Ad, N., Palazzo, T., Fitzpatrick, S., Suyderhoud, J. P., DeGroot, K. W., Pirovic, E. A., Lou, H. G., Duvall, W. Z., & Kim, Y. D. (2000) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1016/s1043-0679(00)70011-6 · Cited by 310
Esophageal injury during radiofrequency ablation for atrial fibrillation
Gillinov, A. M., Pettersson, G., & Rice, T. W. (2001) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.118041 · Cited by 301
Crijns, H. J. G. M., Gelder, I. C. V., van Gilst, W. H., Hillege, H. L., Gosselink, A. M., & Lie, K. I. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90828-9 · Cited by 275
Atrial fibrillation and stroke: new ideas, persisting dilemmas
Halperin, J. L., & Hart, R. G. (1988) · Stroke · doi:10.1161/01.str.19.8.937 · Cited by 231
Proarrhythmia in Patients Treated for Atrial Fibrillation or Flutter
Falk, R. H. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-2-141 · Cited by 184
Cerebrovascular Complication Associated with Pulmonary Vein Ablation
Kok, L. C., Mangrum, J. M., Haines, D. E., & Mounsey, J. P. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.00764.x · Cited by 183
Gaïta, F., Riccardi, R., Caponi, D., Shah, D. C., Garberoglio, L., Vivalda, L., Dulio, A., Chiecchio, A., Manasse, E., & Gallotti, R. G. (2004) · Circulation · doi:10.1161/01.cir.0000151310.00337.fa · Cited by 172
Newly Diagnosed Atrial Fibrillation and Acute Stroke
Lin, H., Wolf, P. A., Benjamin, E. J., Belanger, A. J., & D’Agostino, R. B. (1995) · Stroke · doi:10.1161/01.str.26.9.1527 · Cited by 171
Chronic transmural atrial ablation by using bipolar radiofrequency energy on the beating heart
Prasad, S. M., Maniar, H. S., Schuessler, R. B., & Damiano, R. J. (2002) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.125057 · Cited by 165
Sönmez, B., Demirsoy, E., Yağan, N., Unal, M. B., Arbatlı, H., Şener, D., Baran, T., & Ilkova, F. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(03)00006-7 · Cited by 145
Kobza, R., Hindricks, G., Tanner, H., Schirdewahn, P., Dorszewski, A., Piorkowski, C., Gerds‐Li, J., & Kottkamp, H. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.08.009 · Cited by 136
Ablation with an internally irrigated radiofrequency catheter: Learning how to avoid steam pops
Cooper, J. M., Sapp, J. L., Tedrow, U. B., Pellegrini, C. P., Robinson, D., Epstein, L. M., & Stevenson, W. G. (2004) · Heart Rhythm · doi:10.1016/j.hrthm.2004.04.019 · Cited by 84
Alternative energy sources for atrial ablation: judging the new technology
Damiano, R. J. (2003) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(02)04844-0 · Cited by 82
Combined atrial fibrillation and mitral valve surgery using microwave technology
Knaut, M., Tugtekin, S. M., Spitzer, S. G., & Gulielmos, V. (2002) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1053/stcs.2002.33754 · Cited by 53
Esophageal perforation during left atrial radiofrequency ablation
Laczkovics, A. M., Khargi, K., & Deneke, T. (2003) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2003.08.007 · Cited by 46
Atrial fibrillation and stroke.
Hart, R. G., Sherman, D. G., & Easton, J. D. (1984) · Stroke · doi:10.1161/01.str.15.2.387 · Cited by 45
Ouyang, F. O., Antz, M., Bänsch, D., Chun, J., Schaumann, A., Falk, P., Schmidt, B., Ernst, S., & Kück, K. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.02.600 · Cited by 22
Hindricks, G., & Kottkamp, H. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.00768.x · Cited by 18
Atrial Fibrillation Therapies – Rate or Rhythm Control?
Friedman, P. A., & Hammill, S. C. (2004) · US Cardiology Review · doi:10.15420/usc.2004.1.1.115 · Cited by 3
Research works printed but not linked: 1
- Oral, 2003, Catheter ablation for paroxysmal atrial fibrillation, Circulation, 108, 2355, 10.1161/01.CIR.0000095796.45180.88 · DOI
Cited by
Sorted by citations
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P. F., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castellà, M., Diener, H., Heidbüchel, H., Hendriks, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw295 · Cited by 6,438
2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS
Kirchhof, P., Benussi, S., Kotecha, D., Ahlsson, A., Atar, D., Casadei, B., Castella, M., Diener, H.-C., Heidbuchel, H., Hendriks, J., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw210 · Cited by 6,418
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,794
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Calkins, H. G., Brugada, J., Packer, D. L., Cappato, R., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Haines, D. E., Haı̈ssaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,690
Metadata
- Authors
- Wolf, R. K., Schneeberger, E. W., Osterday, R., Miller, D., Merrill, W., Flege, J. B., & Gillinov, A. M.
- Affiliations
- University of Cincinnati (US)
- Cleveland Clinic (US)
- Corresponding author
- Wolf, Randall K.
- Venue
- The Journal of Thoracic and Cardiovascular Surgery
- Publisher
- Elsevier BV
- Published
- 2005-09
- Volume
- 130
- Issue
- 3
- Pages
- 797-802
- ISSN
- 0022-5223 (ISSN-L)
- OpenAlex
- W2006201567
- Cited by
- 392
- References
- 34
- Citations by year
- 2026: 3 · 2025: 8 · 2024: 14 · 2023: 14 · 2022: 5 · 2021: 15 · 2020: 13 · 2019: 12 · 2018: 17 · 2017: 24 · 2016: 17 · 2015: 23 · 2014: 18 · 2013: 32 · 2012: 34
- FWCI
- 13.98
- Type
- journal article
- Language
- en
- Update notices
- erratum (2006-04-01)
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Thoracic and Cardiovascular Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- atrial fibrillation, pulmonary vein isolation, left atrial appendage exclusion, video-assisted thoracoscopic surgery, epicardial approach, off-pump surgery, bipolar radiofrequency ablation, minimally invasive cardiac surgery, surgical outcomes, pulmonary vein stenosis
- MeSH terms
- Adult, Aged, Atrial Fibrillation, Female, Cardiac Surgical Procedures, Humans, Male, Middle Aged, Postoperative Complications, Pulmonary Veins, Catheter Ablation, Atrial Appendage, Thoracic Surgery, Video-Assisted
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review