Abstract

Objectives: Clinical translation of tissue-engineered heart valves requires valve competency and lack of stenosis in the short and long term. Early studies of engineered valves showed promise, although lacked complete definition of valve function. Building on prior experiments, we sought to define the in vivo changes in structure and function of autologous engineered pulmonary valved conduits. Methods: Mesenchymal stem cells were isolated from neonatal sheep bone marrow and seeded onto a bioresorbable scaffold. After 4 weeks of culture, valved conduits were implanted. Valve function, cusp, and conduit dimensions were evaluated at implantation (echocardiography), at the experimental midpoint (magnetic resonance imaging), and at explant, at 1 day, and 1, 6, 12, or 20 weeks postoperatively (direct measurement, echocardiography). Histologic evaluation was performed. Results: Nineteen animals underwent autologous tissue-engineered valved conduit replacement. At implantation, valved conduit function was excellent; maximum transvalvular pressure gradient by Doppler echocardiography was 17 mm Hg; most valved conduits showed trivial pulmonary regurgitation. At 6 postoperative weeks, valve cusps appeared less mobile; pulmonary regurgitation was mild to moderate. At 12 weeks or more, valved conduit cusps were increasingly attenuated and regurgitant. Valved conduit diameter remained unchanged over 20 weeks. Dimensional measurements by magnetic resonance imaging correlated with direct measurement at explant. Conclusions: We demonstrate autologous engineered tissue valved conduits that function well at implantation, with subsequent monitoring of dimensions and function in real time by magnetic resonance imaging. In vivo valves undergo structural and functional remodeling without stenosis, but with worsening pulmonary regurgitation after 6 weeks. Insights into mechanisms of in vivo remodeling are valuable for future iterations of engineered heart valves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jtcvs.2009.11.006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 142

Metadata

Authors
Gottlieb, D., Kunal, T., Emani, S., Aikawa, E., Brown, D. W., Powell, A. J., Nedder, A., Engelmayr, G. C., Melero-Martin, J. M., Sacks, M. S., & Mayer, J. E.
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
2010-03
Volume
139
Issue
3
Pages
723-731
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2072868907
Cited by
142
References
1
FWCI
13.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In vivo monitoring of function of autologous engineered pulmonary valve. https://app.cochat.ai/papers/10.1016/j.jtcvs.2009.11.006
The paper
Gottlieb, D., Kunal, T., Emani, S., Aikawa, E., Brown, D. W., Powell, A. J., Nedder, A., Engelmayr, G. C., Melero-Martin, J. M., Sacks, M. S., & Mayer, J. E. (2010). In vivo monitoring of function of autologous engineered pulmonary valve. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2009.11.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.