Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Development and Initial Validation of a Scoring System to Diagnose Testicular Torsion in Children

Barbosa, João A., Tiseo, Bruno Camargo, Barayan, Ghassan A., Rosman, Brian M., Torricelli, Fábio César Miranda, Passerotti, Carlo C., Srougi, Miguel, Retik, Alan B., Nguyen, Hiep T. · 2013 · Journal of Urology

Abstract

PURPOSE: Testicular torsion is a surgical emergency requiring prompt intervention. Although clinical diagnosis is recommended, scrotal ultrasound is frequently ordered, delaying treatment. We created a scoring system to diagnose testicular torsion, decreasing the indication for ultrasound. MATERIALS AND METHODS: We prospectively evaluated 338 patients with acute scrotum, of whom 51 had testicular torsion. Physical examination was performed by a urologist, and all patients underwent scrotal ultrasound. Univariate analysis and logistic regression were performed, and a scoring system for risk stratification of torsion was created. Retrospective validation was performed with 2 independent data sets. RESULTS: The scoring system consisted of testicular swelling (2 points), hard testicle (2), absent cremasteric reflex (1), nausea/vomiting (1) and high riding testis (1). Cutoffs for low and high risk were 2 and 5 points, respectively. Ultrasound would be indicated only for the intermediate risk group. In the prospective data set 69% of patients had low, 19% intermediate and 11.5% high risk. Negative and positive predictive values were 100% for cutoffs of 2 and 5, respectively (specificity 81%, sensitivity 76%). Retrospective validation in 1 data set showed 66% of patients at low, 16% intermediate and 17% high risk. Negative and positive predictive values for cutoffs of 2 and 5 were 100% (specificity 97%, sensitivity 54%). The second retrospective data set included only torsion cases, none of which was misdiagnosed by the scoring system. CONCLUSIONS: This scoring system can potentially diagnose or rule out testicular torsion in 80% of cases, with high positive and negative predictive values for selected cutoffs. Ultrasound orders would be decreased to 20% of acute scrotum cases. Prospective validation of this scoring system is necessary.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.juro.2012.10.056

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Metadata

Authors
Barbosa, J. A., Tiseo, B. C., Barayan, G. A., Rosman, B. M., Torricelli, F. C. M., Passerotti, C. C., Srougi, M., Retik, A. B., & Nguyen, H. T.
Venue
Journal of Urology
Published
2013-05
Volume
189
Issue
5
Pages
1859-1864
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2114774970
Cited by
175
References
1
FWCI
2.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development and Initial Validation of a Scoring System to Diagnose Testicular Torsion in Children. https://app.cochat.ai/papers/10.1016/j.juro.2012.10.056
The paper
Barbosa, J. A., Tiseo, B. C., Barayan, G. A., Rosman, B. M., Torricelli, F. C. M., Passerotti, C. C., Srougi, M., Retik, A. B., & Nguyen, H. T. (2013). Development and Initial Validation of a Scoring System to Diagnose Testicular Torsion in Children. Journal of Urology. https://doi.org/10.1016/j.juro.2012.10.056

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.