Practice Patterns and Outcomes of Open and Minimally Invasive Partial Nephrectomy Since the Introduction of Robotic Partial Nephrectomy: Results from the Nationwide Inpatient Sample
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: We determined practice patterns and perioperative outcomes of open and minimally invasive partial nephrectomy in the United States since the introduction of a robot-assisted modifier in the Nationwide Inpatient Sample. MATERIALS AND METHODS: We identified all patients with nonmetastatic disease treated with open, laparoscopic or robotic partial nephrectomy in the Nationwide Inpatient Sample between October 2008 and December 2010. Utilization rates were assessed by year, patient and hospital characteristics. We evaluated the perioperative outcomes of open vs robotic and open vs laparoscopic partial nephrectomy using binary logistic regression models adjusted for patient and hospital covariates. RESULTS: In a weighted sample of 38,064 partial nephrectomies 66.9%, 23.9% and 9.2% of the procedures were open, robotic and laparoscopic operations, respectively. In 2010 the relative annual increase in open, robotic and laparoscopic partial nephrectomy was 7.9%, 45.4% and 6.1%, respectively. Compared to open partial nephrectomy patients treated with minimally invasive partial nephrectomy were less likely to receive blood transfusion (robotic vs laparoscopic OR 0.56, p <0.001 vs OR 0.68, p = 0.016), postoperative complication (OR 0.63, p <0.001 vs OR 0.78, p <0.009) or prolonged length of stay (OR 0.27 vs OR 0.41, each p <0.001). Only patients who underwent the robotic procedure were less likely to experience an intraoperative complication (robotic vs laparoscopic OR 0.69, p = 0.014 vs OR 0.67, p = 0.069). Excess hospital charges were higher after robotic surgery (OR 1.35, p <0.001). CONCLUSIONS: The dissemination of robotic surgery for partial nephrectomy in the United States has been rapid and safe. Compared to open partial nephrectomy the robotic procedure had lower odds than laparoscopic partial nephrectomy for most study outcomes except hospital charges. Robotic partial nephrectomy has now supplanted laparoscopic partial nephrectomy as the most common minimally invasive approach for partial nephrectomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adapting a clinical comorbidity index for use with ICD-9-CM administrative databases
DEYO, R. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90133-8 · Cited by 10,452
No surgical innovation without evaluation: the IDEAL recommendations
McCulloch, P., Altman, D. G., Campbell, W. B., Flum, D. R., Glasziou, P., Marshall, J. C., & Nicholl, J. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61116-8 · Cited by 1,820
Cited by
Cacciamani, G. E., Medina, L. G., Gill, T., Abreu, A., Sotelo, R., Artibani, W., & Gill, I. S. (2018) · Journal of Urology · doi:10.1016/j.juro.2017.12.086 · Cited by 163
Metadata
- Authors
- Ghani, K. R., Sukumar, S., Sammon, J. D., Rogers, C. G., Trinh, Q.-D., & Menon, M.
- Venue
- Journal of Urology
- Published
- 2014-04
- Volume
- 191
- Issue
- 4
- Pages
- 907-913
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2146575167
- Cited by
- 242
- References
- 2
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practice Patterns and Outcomes of Open and Minimally Invasive Partial Nephrectomy Since the Introduction of Robotic Partial Nephrectomy: Results from the Nationwide Inpatient Sample. https://app.cochat.ai/papers/10.1016/j.juro.2013.10.099
- The paper
- Ghani, K. R., Sukumar, S., Sammon, J. D., Rogers, C. G., Trinh, Q.-D., & Menon, M. (2014). Practice Patterns and Outcomes of Open and Minimally Invasive Partial Nephrectomy Since the Introduction of Robotic Partial Nephrectomy: Results from the Nationwide Inpatient Sample. Journal of Urology. https://doi.org/10.1016/j.juro.2013.10.099
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.