Cited by 19Aortic Disease and Treatment ApproachesAortic aneurysm repair treatmentsInfectious Aortic and Vascular Conditions

The DOI matches its Crossref record.

Analysis of predisposing factors for type III endoleaks from directional branches after branched endovascular repair for thoracoabdominal aortic aneurysms

Open access

Abstract

Background Mid-term durability of branches has already been established, and BF-branched and fenestrated endovascular repair has shown comparable results with open repair in the treatment of thoracoabdominal aortic aneurysms (TAAAs). Nevertheless, target vessel instability remains the most frequent adverse event after complex endovascular aortic repair. Type III endoleaks from directional branches have been reported with a low incidence, but risk factors for this complication have not been investigated yet. Methods This was a dual-center observational retrospective cohort study. Data were collected prospectively for each patient treated with branched endovascular repair between April 2008 and December 2019. The primary outcome was to assess potential risk factors for branch disconnection and fracture. A logistic regression analysis was performed, including preoperative and postoperative measurements as well as intraoperative details. A Cox regression hazard analysis was performed to evaluate the influence of preoperative aneurysm diameter and target vessel angulation on the outcome during follow-up. Results Two hundred ninety-five target visceral vessels (TVVs) in 91 patients were considered suitable for cannulation. Technical success was 96.9% (286/295 TVVs). The median follow-up was 32.5 months (interquartile range, 14.2-50.1 months). Twelve type III endoleaks from directional branches were detected (4.2%; 5 bridging stent graft fractures and 7 disconnections). Five type III endoleaks involved the celiac trunk (one fracture and four disconnections), five the superior mesenteric artery (four fractures and one disconnection), and two the renal arteries (both disconnections). The median time to type III endoleak was 22.2 months (interquartile range, 10.9-37.6 months). Preoperative TAAA diameter (P = .028), preoperative TVV angulation (P = .037), the use of a BeGraft stent graft as bridging stent graft (P = .001), and different stent types on the same vessel (P = .048) were associated with type III endoleak at univariable analysis. Using a BeGraft stent graft (P = .010) was the only significant factor predisposing to type III endoleak at multiple logistic regression. The Cox regression analysis showed a two-fold increased risk for type III endoleak for every 10-mm increase in preoperative TAAA diameter (hazard ratio, 2.00; 95% confidence interval, 1.08-3.72; P = .028) and a 1.5 increased risk every 12° increase of preoperative TVV angulation (hazard ratio, 1.47; 95% confidence interval, 1.02-2.10; P = .037). Conclusions Type III endoleaks from directional branches are a non-negligible complication after branched endovascular repair, with a relevant incidence. They tended to be clustered on specific patients, and aneurysm diameter and TVV angulation are strictly associated with the outcome. Different stent types on the same vessel should be avoided whenever possible. An intensified follow-up should be adopted for patients with large aneurysms, implanted with first-generation BeGraft, or who have been already diagnosed with type III endoleaks.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.jvs.2022.10.041

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 31

  1. Reilly, 2012, Efficacy and durability of endovascular thoracoabdominal aortic aneurysm repair using the caudally directed cuff technique, J Vasc Surg, 56, 53, 10.1016/j.jvs.2012.01.006 · DOI
  2. Chuter, 2006, Branched and fenestrated stent grafts for endovascular repair of thoracic aortic aneurysms, J Vasc Surg, 43, 111A, 10.1016/j.jvs.2005.10.059 · DOI
  3. Riambau, 2017, Editor’s choice – management of descending thoracic aorta diseases, Eur J Vasc Endovasc Surg, 53, 4, 10.1016/j.ejvs.2016.06.005 · DOI
  4. Silingardi, 2018, Standard “off-the-shelf” multibranched thoracoabdominal endograft in urgent and elective patients with single and staged procedures in a multicenter experience, J Vasc Surg, 67, 1005, 10.1016/j.jvs.2017.08.068 · DOI
  5. Mastracci, 2013, Durability of branches in branched and fenestrated endografts, J Vasc Surg, 57, 926, 10.1016/j.jvs.2012.09.071 · DOI
  6. Panuccio, 2015, Performance of bridging stent grafts in fenestrated and branched aortic endografting, Eur J Vasc Endovas Surg, 50, 60, 10.1016/j.ejvs.2015.03.023 · DOI
  7. Silverberg, 2020, Secondary interventions after fenestrated and branched endovascular repair of complex aortic aneurysms, J Vasc Surg, 72, 866, 10.1016/j.jvs.2019.10.068 · DOI
  8. Simons, 2021, Evolution of fenestrated/branched endovascular aortic aneurysm repair complexity and outcomes at an organized center for the treatment of complex aortic disease, J Vasc Surg, 73, 1148, 10.1016/j.jvs.2020.07.100 · DOI
  9. Dossabhoy, 2018, Reinterventions after fenestrated or branched endovascular aortic aneurysm repair, J Vasc Surg, 68, 669, 10.1016/j.jvs.2017.12.036 · DOI
  10. Fidalgo-Domingos, 2020, Geometric and hemodynamic analysis of fenestrated and multibranched aortic endografts, J Vasc Surg, 72, 1567, 10.1016/j.jvs.2020.01.040 · DOI
  11. Giles, 2019, Impact of secondary interventions on mortality after fenestrated branched endovascular aortic aneurysm repair, J Vasc Surg, 70, 1737, 10.1016/j.jvs.2019.02.029 · DOI
  12. Verhoeven, 2015, Editor’s choice – ten-year experience with endovascular repair of thoracoabdominal aortic aneurysms: results from 166 consecutive patients, Eur J Vasc Endovasc Surg, 49, 524, 10.1016/j.ejvs.2014.11.018 · DOI
  13. Tenorio, 2020, Outcomes of directional branches using self-expandable or balloon-expandable stent grafts during endovascular repair of thoracoabdominal aortic aneurysms, J Vasc Surg, 71, 1489, 10.1016/j.jvs.2019.07.079 · DOI
  14. Troisi, 2011, Secondary procedures after aortic aneurysm repair with fenestrated and branched endografts, J Endovasc Ther, 18, 146, 10.1583/10-3274.1 · DOI
  15. Mastracci, 2016, Editor’s choice – effect of branch stent choice on branch-related outcomes in complex aortic repair, Eur J Vasc Endovasc Surg, 51, 536, 10.1016/j.ejvs.2015.12.046 · DOI
  16. Gennai, 2022, Bridging stent-graft fracture after branched endovascular aortic repair in a dual-center retrospective cohort study, J Vasc Surg, 75, 425, 10.1016/j.jvs.2021.08.053 · DOI
  17. Oderich, 2021, Reporting standards for endovascular aortic repair of aneurysms involving the renal-mesenteric arteries, J Vasc Surg, 73, 4S, 10.1016/j.jvs.2020.06.011 · DOI
  18. Sugimoto, 2016, Tortuosity is the significant predictive factor for renal branch occlusion after branched endovascular aortic aneurysm repair, Eur J Vasc Endovasc Surg, 51, 350, 10.1016/j.ejvs.2015.09.013 · DOI
  19. Mezzetto, 2021, Bridging stents in fenestrated and branched endovascular aneurysm repair: a systematic review, Ann Vasc Surg, 73, 454, 10.1016/j.avsg.2020.10.052 · DOI
  20. Hauck, 2022, Structural failure in bridging stentgrafts for branched endovascular aneurysm repair: a case-control study, Insights Imaging, 13, 62, 10.1186/s13244-022-01196-6 · DOI
  21. Diamond, 2021, Effect of thoracoabdominal aortic aneurysm extent on outcomes in patients undergoing fenestrated/branched endovascular aneurysm repair, J Vasc Surg, 74, 833, 10.1016/j.jvs.2021.01.062 · DOI
  22. Kärkkäinen, 2020, Outcomes of target vessel endoleaks after fenestrated-branched endovascular aortic repair, J Vasc Surg, 72, 445, 10.1016/j.jvs.2019.09.055 · DOI
  23. Fazzini, 2021, Aortic endograft and bridging stent-graft remodeling after branched endovascular aortic repair, Vascular, 29, 808, 10.1177/1708538120983698 · DOI
  24. Suh, 2016, Three-dimensional modeling analysis of visceral arteries and kidneys during respiration, Ann Vasc Surg, 34, 250, 10.1016/j.avsg.2016.04.004 · DOI
  25. Lindström, 2020, Outcome after fenestrated and branched repair of aortic aneurysms—device failures predict reintervention rates, Ann Vasc Surg, 66, 142, 10.1016/j.avsg.2019.10.053 · DOI
  26. Spear, 2018, One year outcomes of 101 begraft stent grafts used as bridging stents in fenestrated endovascular repairs, Eur J Vasc Endovasc Surg, 55, 504, 10.1016/j.ejvs.2018.01.023 · DOI
  27. Abisi, 2021, The early outcomes of begraft peripheral plus in branched endovascular repair of thoracoabdominal aneurysms, J Endovasc Ther, 28, 707, 10.1177/15266028211025019 · DOI
  28. Gennai, 2019, Early experience with the covera stent graft as a bridging stent in branched thoraco-abdominal endovascular aneurysm repairs, J Vasc Interv Radiol, 30, 1949, 10.1016/j.jvir.2019.08.006 · DOI
  29. Torsello, 2021, Performance of the gore VBX balloon expandable endoprosthesis as bridging stent-graft in branched endovascular aortic repair for thoracoabdominal aneurysms, J Endovasc Ther, 28, 549, 10.1177/15266028211010455 · DOI
  30. Motta, 2021, Performance of Viabahn balloon expandable stent (VBX) compared to self-expandable covered (SES) stents for branched endovascular aortic repair, J Vasc Surg, 73, 410, 10.1016/j.jvs.2020.05.028 · DOI
  31. Gallitto, 2018, Renal artery orientation influences the renal outcome in endovascular thoraco-abdominal aortic aneurysm repair, Eur J Vasc Endovasc Surg, 56, 382, 10.1016/j.ejvs.2018.06.007 · DOI

Cited by

Sorted by citations

Metadata

Authors
Gennai, S., Simonte, G., Mattia, M., Leone, N., Isernia, G., Fino, G., Farchioni, L., Lenti, M., & Silingardi, R.
Affiliations
  • University of Modena and Reggio Emilia (IT)
  • University of Perugia (IT)
Venue
Journal of Vascular Surgery
Publisher
Elsevier BV
Published
2023-03
Volume
77
Issue
3
Pages
677-684
ISSN
0741-5214 (ISSN-L)
OpenAlex
W4308154029
Cited by
19
References
0
Citations by year
2026: 5 · 2025: 4 · 2024: 6 · 2023: 4
FWCI
2.27
Type
journal article
Language
en
Open access
Locations
  • Journal of Vascular Surgery (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
  • IRIS UNIMORE (University of Modena and Reggio Emilia) (submittedVersion, cc-by)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Aortic Disease and Treatment Approaches
  • Health Sciences › Medicine › Surgery › Aortic aneurysm repair treatments
  • Health Sciences › Medicine › Surgery › Infectious Aortic and Vascular Conditions
Keywords
thoracoabdominal aortic aneurysm, target vessel instability, bridging stent graft, aneurysm diameter, celiac artery, superior mesenteric artery, renal artery
MeSH terms
Aortic Aneurysm, Thoracoabdominal, Blood Vessel Prosthesis, Humans, Prosthesis Design, Retrospective Studies, Risk Factors, Treatment Outcome, Aortic Aneurysm, Abdominal, Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Endovascular Procedures, Endoleak

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review