Automated arrhythmia detection using novel hexadecimal local pattern and multilevel wavelet transform with ECG signals
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Abstract Electrocardiography (ECG) is widely used for arrhythmia detection nowadays. The machine learning methods with signal processing algorithms have been used for automated diagnosis of cardiac health using ECG signals. In this article, discrete wavelet transform (DWT) coupled with novel 1-dimensional hexadecimal local pattern (1D-HLP) technique are employed for automated detection of arrhythmia detection. The ECG signals of 10 s duration are subjected to DWT to decompose up to five levels. The 1D-HLP extracts 512 dimensional features from each level of the five levels of low pass filter. Then, these extracted features are concatenated to obtain 512 × 6 = 3072 dimensional feature set. These fused features are subjected to neighborhood component analysis (NCA) feature reduction technique to obtain 64, 128 and 256 features. Finally, these features are subjected to 1 nearest neighborhood (1NN) classifier for classification with 4 distance metrics namely city block, Euclidean, spearman and cosine. We have obtained a classification accuracy of 95.0% in classifying 17 arrhythmia classes using MIT-BIH Arrhythmia ECG dataset. Our results show that the proposed method is more superior than other already reported classical ensemble learning and deep learning methods for arrhythmia detection using ECG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
ECG beat classification using PCA, LDA, ICA and Discrete Wavelet Transform
Martis, R. J., Acharya, U. R., & Min, L. C. (2013) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.01.005 · Cited by 722
Self-citation
Cited by
Murat, F., Yildirim, O., Talo, M., Baloglu, U. B., Demir, Y., & Acharya, U. R. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103726 · Cited by 326
Tuncer, T., Dogan, S., & Ozyurt, F. (2020) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2020.104054 · Cited by 177
“(13) – (17) [46 – 48]. where TP , TN , FP ; and FN are true positive, true negative, false positive, and false negative respectively.”
Self-citationA comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Tuncer, T., Dogan, S., Pławiak, P., & Rajendra Acharya, U.
- Venue
- Knowledge-Based Systems
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 186
- Pages
- 104923
- ISSN
- 0950-7051 (ISSN-L)
- OpenAlex
- W2967246721
- Cited by
- 223
- References
- 3
- FWCI
- 21.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.