Fabrication of strong, bioactive vascular grafts with PCL/collagen and PCL/silica bilayers for small-diameter vascular applications
Open accessAbstract
In vascular surgical applications, small-diameter vascular grafts made from synthetic polymers are rarely commercialized, owing to delayed reendothelialization and subsequent thrombus formation and occlusion. Here, we describe a novel design for a small-diameter poly-ε-caprolactone (PCL) vascular graft with a functional, bilayered nanofibrous structure and a composition that enables a suitable healing process and gradual degradation/replacement by natural blood vessels. To improve vascular cell responses to the PCL, a natural bioactive polymer (collagen) and a sol–gel-derived bioceramic (silica) were incorporated into the inner and outer layer of the PCL vascular graft, respectively. An electrospinning technique enabled the development of uniform electrospun PCL/collagen and PCL/silica nanofibers. In particular, the orientations of PCL/collagen nanofibers prepared with a high-speed rotating collector were highly aligned, and no breaks or irregular shapes were observed. The thin inner layer, composed of PCL/collagen with longitudinally aligned nanofibers, was favorable for the adhesion, elongation, and migration of endothelial cells, thus eliciting rapid reendothelialization of luminal surfaces of a vascular graft. The relatively thick outer layer, composed of PCL/silica with randomly distributed nanofibers, provided a superior mechanical strength and showed satisfactory biocompatibility. The findings of this study demonstrate a strong potential of PCL-based bilayer vascular grafts for vascular tissue applications.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
PCL/collagen blend is a promising material for skin and vascular TE.
“PCL/collagen blend is a promising material for skin [153,154,155,156,157,158] and vascular TE [159,160,161].”
From Resorbable Biomaterials Used for 3D Scaffolds in Tissue Engineering: A Review (2023) · cites this paper as [160]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- N. Awad, H. Niu, U. Ali, Y. Morsi, T. Lin, Electrospun fibrous scaffolds for small- diameter blood vessels: a review, Membranes 8 (1) (2018) 15.
- R.H. Liu, C.S. Ong, T. Fukunishi, K. Ong, N. Hibino, Review of vascular graft studies in large animal models, Tissue Eng. B Rev. 24 (2) (2018) 133-143.
Cited by
Sorted by citations
Resorbable Biomaterials Used for 3D Scaffolds in Tissue Engineering: A Review
Vach Agocsova, S., Culenova, M., Birova, I., Omanikova, L., Moncmanova, B., Danisovic, L., Ziaran, S., Bakos, D., & Alexy, P. (2023) · Materials · doi:10.3390/ma16124267 · Cited by 98 · see citing works
- Authors
- Park, S., Kim, J., Lee, M.-K., Park, C., Jung, H.-D., Kim, H.-E., & Jang, T.-S.
- Affiliations
- Seoul National University (KR)
- Korea Institute of Industrial Technology (KR)
- Corresponding author
- Jang, Tae-Sik
- Venue
- Materials & Design
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 181
- Pages
- 108079
- ISSN
- 0264-1275 (ISSN-L)
- OpenAlex
- W2965575729
- Cited by
- 126
- References
- 1
- Citations by year
- 2026: 14 · 2025: 8 · 2024: 22 · 2023: 20 · 2022: 25 · 2021: 26 · 2020: 8 · 2019: 3
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Materials & Design (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Seoul National University
- Topics
- Physical Sciences › Materials Science › Biomaterials › Electrospun Nanofibers in Biomedical Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- small-diameter vascular grafts, polycaprolactone, collagen, silica, electrospinning, re-endothelialization, rotating collector, nanofiber alignment, bioceramics, sol-gel, biodegradation, biocompatibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review