Design of a biomimetic graded TPMS scaffold with quantitatively adjustable pore size
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The advantages of “printing the right material in the right position” and “printing the unique structure for unique function” in additive manufacturing make the design of biomimetic graded scaffold of bone tissue engineering possible. Here, under different porosities, we propose a biomimetic graded TPMS scaffold design with adjustable graded pore size, providing guidance for designing porous bone implants without the characteristics of stress concentration, stress shielding and barrier mass transport. Specifically, the structural characteristics of TPMS can be achieved without stress concentration. By adjusting the porosity, the elastic modulus of Ti6Al4V samples can be adjusted in the range of 1158–4567 MPa, which can match the individual selection of mechanical properties of the biological bone. Since the TPMS scaffold is designed by layer-by-layer splicing, through adjusting the height parameters of the single-layer structure, the selective pore size variation can be realized to further match mass transport of biological bone. Then, the in vitro culture experiments have been conducted and the maximum cell survival rate of the scaffold with an offset constant 0.4 is 85.44%, which can meet the mass transport of bone implants. As such, the proposed graded scaffold design in this paper shows excellent potential for orthopedic implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE MATERIAL BONE: Structure-Mechanical Function Relations
Weiner, S., & Wagner, H. D. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.271 · Cited by 2,724
SLM lattice structures: Properties, performance, applications and challenges
Maconachie, T., Leary, M., Lozanovski, B., Zhang, X., Qian, M., Faruque, O., & Brandt, M. (2019) · Materials & Design · doi:10.1016/j.matdes.2019.108137 · Cited by 1,497
Yan, C., Hao, L., Hussein, A., Young, P., & Raymont, D. (2014) · Materials & Design · doi:10.1016/j.matdes.2013.10.027 · Cited by 622
Danilevicius, P., Georgiadi, L., Pateman, C. J., Claeyssens, F., Chatzinikolaidou, M., & Farsari, M. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2014.06.012 · Cited by 117
Cited by
Design, printing, and engineering of regenerative biomaterials for personalized bone healthcare
Jia, Z., Xu, X., Zhu, D., & Zheng, Y. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101072 · Cited by 176
Metadata
- Authors
- Zhang, J., Chen, X., Sun, Y., Yang, J., Chen, R., Xiong, Y., Hou, W., & Bai, L.
- Venue
- Materials & Design
- Publisher
- Elsevier BV
- Published
- 2022-06
- Volume
- 218
- Pages
- 110665
- ISSN
- 0264-1275 (ISSN-L)
- OpenAlex
- W4224278477
- Cited by
- 161
- References
- 4
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a biomimetic graded TPMS scaffold with quantitatively adjustable pore size. https://app.cochat.ai/papers/10.1016/j.matdes.2022.110665
- The paper
- Zhang, J., Chen, X., Sun, Y., Yang, J., Chen, R., Xiong, Y., Hou, W., & Bai, L. (2022). Design of a biomimetic graded TPMS scaffold with quantitatively adjustable pore size. Materials & Design. https://doi.org/10.1016/j.matdes.2022.110665
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.