The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Adaptive readout approaches of resistive sensor array for wearable electronics applications
Open accessAbstract
Sensor arrays are widely used to extract the distribution of variables in large sensing areas or collect multi-degree-of-freedom data. In this paper, we propose adaptive resistance matrix approaches, which can get rid of additional electrical components such as diodes, transistors, multiplexers, op-amps, switches, and current sources. By eliminating the power supply parameters, these approaches can show great advantages and application potential when they are used to measure wearable flexible sensor arrays or other low-cost sensor arrays. Experimental results have shown that the proposed approaches achieved a high accuracy (99.45% and 99.80%), large measurement range (0.5∼1.5 times the reference resistance value), and relatively low crosstalk error (0.066% and 0.128%). The approach was then applied to a flexible strain sensor array to estimate the three-degree-of-freedom lumbar spine motion, and the results have shown that the resistance distribution of the sensor array can clearly show the strain distribution under different lumbar movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Flagged first, then by citations
Research works printed but not linked: 37
- Depari, 2007, A new low-cost electronic system to manage resistive sensors for gas detection, IEEE Sens. J., 10.1109/JSEN.2007.895965 · DOI
- Beccherelli, 2010, Design of a very large chemical sensor system for mimicking biological olfaction, Sensors and Actuators B-Chemical., 10.1016/j.snb.2009.11.031 · DOI
- Grassi, 2005, A high-precision wide-range front-end for resistive gas sensors arrays, Sensors and Actuators B-Chemical., 10.1016/j.snb.2005.03.103 · DOI
- Prutchi, 1993, Dynamic contact stress analysis using a compliant sensor array, Measurement, 10.1016/0263-2241(93)90039-K · DOI
- Snyder, 1978, Conductive elastomers as sensor for industrial parts handling equipment, IEEE Trans. Instrum. Meas., 10.1109/TIM.1978.4314628 · DOI
- Kane, 2000, A traction stress sensor array for use in high-resolution robotic tactile imaging, IEEE/ASME, J. Microelectromech. Syst., 10.1109/84.896763 · DOI
- Vidal-Verdú, 2011, Three realizations and comparison of hardware for piezoresistive tactile sensors, Sensors., 10.3390/s110303249 · DOI
- B. Tise, A compact high resolution piezoresistive digital tactile sensor, In: 1988 IEEE International Conference on Robotics and Automation Proceedings, 1988: pp. 760–764 vol.2. https://doi.org/10.1109/ROBOT.1988.12150. · DOI
- Tanaka, 1996, Infrared focal plane array incorporating silicon IC process compatible bolometer, IEEE Trans. Electron Devices, 10.1109/16.543017 · DOI
- Wang, 2005, Signal processing algorithms for fire localization using temperature sensor arrays, Fire Saf. J., 10.1016/j.firesaf.2005.06.004 · DOI
- Saxena, 2006, A novel test structure for process control monitor for un-cooled bolometer area array detector technology, J. Semicond. Technol. Sci., 6, 299
- Saxena, 2012, PSPICE circuit simulation of microbolometer infrared detectors with noise sources, Infrared Phys. Technol., 10.1016/j.infrared.2012.07.004 · DOI
- Wu, 2016, A handwriting input method based on the thermal cue of the fingertip, Measurement, 10.1016/j.measurement.2016.05.097 · DOI
- Saxena, 2011, Analysis of crosstalk in networked arrays of resistive sensors, IEEE Sensors J., 11, 920, 10.1109/JSEN.2010.2063699 · DOI
- Wu, 2015, Design and crosstalk error analysis of the circuit for the 2-D networked resistive sensor array, IEEE Sens. J., 10.1109/JSEN.2014.2359967 · DOI
- Oballe-Peinado, 2016, Accuracy and resolution analysis of a direct resistive sensor array to FPGA interface, Sensors, 10.3390/s16020181 · DOI
- Oballe-Peinado, 2016, Improved circuits with capacitive feedback for readout resistive sensor arrays, Sensors, 10.3390/s16020149 · DOI
- Jianfeng, 2011, A small size device using temperature sensor array, Chin. J. Sens. Actuators, 24, 1649
- Liu, 2010, Measurement errors in the scanning of resistive sensor arrays, Sensors and Actuators A-Physical., 10.1016/j.sna.2010.08.004 · DOI
- D’Alessio, 1999, Measurement errors in the scanning of piezoresistive sensors arrays, Sensors and Actuators A-Physical., 10.1016/S0924-4247(98)00204-0 · DOI
- Wu, 2015, General voltage feedback circuit model in the two-dimensional networked resistive sensor array, Journal of Sensors.
- Lazzarini, 1995, A tactile array sensor layered in an artificial skin, vol. 3, 114
- Saxena, 2011, Virtual ground technique for crosstalk suppression in networked resistive sensors, IEEE Sens. J.
- Yarahmadi, 2016, An improved-accuracy approach for readout of large-array resistive sensors, IEEE Sens. J., 10.1109/JSEN.2015.2477494 · DOI
- Wu, 2016, Approximate model of zero potential circuits for the 2-D networked resistive sensor array, IEEE Sens. J., 10.1109/JSEN.2016.2530692 · DOI
- Kim, 2016, High-accuracy, compact scanning method and circuit for resistive sensor arrays, Sensors
- Lorussi, 2004, Wearable, redundant fabric-based sensor arrays for reconstruction of body segment posture, IEEE Sens. J., 10.1109/JSEN.2004.837498 · DOI
- Shu, 2015, A new approach for readout of resistive sensor arrays for wearable electronic applications, IEEE Sensors J., 15, 442, 10.1109/JSEN.2014.2333518 · DOI
- Li, 2013, Reconfigurable bioimpedance emulation system for electrical impedance tomography system validation, IEEE Trans. Biomed. Circuits Syst.
- Tucker, 2013, Biocompatible, high precision, wideband, improved howland current source with lead-lag compensation, IEEE Trans. Biomed. Circuits Syst., 10.1109/TBCAS.2012.2199114 · DOI
- Kato, 2007, Tactile sensor without wire and sensing element in the tactile region based on EIT method, IEEE SENSORS, 2007, 792
- H. Alirezaei, A. Nagakubo, Y. Kuniyoshi, A Tactile Distribution Sensor Which Enables Stable Measurement Under High and Dynamic Stretch, In: K. Kiyokawa, S. Coquillart, R. Balakrishnan (Eds.), 3DUI : IEEE SYMPOSIUM ON 3D USER INTERFACES 2009, PROCEEDINGS, IEEE; IEEE Comp Soc; IEEE, VGTC, 2009: p. 87+. https://doi.org/10.1109/3DUI.2009.4811210. · DOI
- Wu, 2019, Improved resistance matrix approach for readout of the two-dimensional resistive sensor array, Trans. Inst. Meas. Control, 41, 875, 10.1177/0142331218774095 · DOI
- Wu, 2017, Scanning approaches of 2-D resistive sensor arrays: A review, IEEE Sensors J., 17, 914, 10.1109/JSEN.2016.2641001 · DOI
- Vu, 2020, Lumbar posture assessment with fabric strain sensors, Comput. Biol. Med., 118, 10.1016/j.compbiomed.2020.103624 · DOI
- Pistolesi, 2020, Assessing the risk of low back pain and injury via inertial and barometric sensors, IEEE Trans. Ind. Inf., 16, 7199, 10.1109/TII.2020.2992984 · DOI
- Chen, 2022, Low-cost design for a Carbon-based fabric strain sensor, Mater. Des., 221, 10.1016/j.matdes.2022.110926 · DOI
Metadata
- Authors
- Zhang, Z., Chen, X., Shu, L., & Xu, X.
- Affiliations
- South China University of Technology (CN)
- Corresponding author
- Shu, Lin
- Xu, Xiangmin
- Venue
- Measurement
- Publisher
- Elsevier BV
- Published
- 2023-11
- Volume
- 221
- Pages
- 113524
- ISSN
- 0263-2241 (ISSN-L)
- OpenAlex
- W4386388317
- Cited by
- 7
- References
- 2
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 1
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Measurement (publishedVersion, cc-by-nc-nd)
- Topics
- Physical Sciences › Physics and Astronomy › Instrumentation › Sensor Technology and Measurement Systems
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- resistance matrix, wearable electronics, flexible strain sensors, lumbar spine mobility, crosstalk, strain distribution measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review