The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A description of an accelerometer-based mobility monitoring technique
Abstract
Accurate monitoring of the mobility status of older adults, over the long-term, is important in rehabilitation medicine, as regular physical activity is central to maintaining both physical and mental health, as well as evaluating quality of life. This technical note describes an accelerometer-based mobility monitoring technique, which can distinguish between static and dynamic activities and can detect the basic postures of sitting, standing and lying. The technique allows thresholds for these postures to be set and two different posture threshold methods are described: mid-point and "best estimate". Preliminary results from using these methods are presented. This preliminary evaluation of the technique was carried out over the long-term (>29 h) in an uncontrolled environment and the method used to carry out the evaluation is described in detail. The two different posture thresholding methods were tested on long-term mobility data from one older adult subject. The subject did not have to follow a specific activity protocol during the recording period (4 days) and was shadowed by an observer in order to evaluate the accuracy of this technique. The monitoring hardware consisted of two accelerometer devices, one on the trunk and the other on the thigh and a pocket-sized ambulatory data-logger. Applying 'best estimate' thresholding, as opposed to mid-point thresholding, improved sitting detection accuracy by 18%, to 93% and lying detection accuracy by 5%, to 84%. Thus, based on these preliminary data, an accurate mobility monitoring system for older adults is described and it was observed that the actual posture threshold limits applied have a high impact on the mobility monitoring system's accuracy and are particularly important for accurately detecting postures when used over the long-term, in an uncontrolled environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of exercise training on older patients with major depression
Blumenthal, J. A., Babyak, M. A., Moore, K. A., Craighead, W. E., Herman, S., Khatri, P., Waugh, R., Napolitano, M. A., Forman, L. M., Appelbaum, M., et al. (1999) · Archives of Internal Medicine · doi:10.1001/archinte.159.19.2349 · Cited by 1,277
Cited by
A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Physical Human Activity Recognition Using Wearable Sensors
Attal, F., Mohammed, S., Dedabrishvili, M., Chamroukhi, F., Oukhellou, L., & Amirat, Y. (2015) · Sensors · doi:10.3390/s151229858 · Cited by 796
Grant, P. M., Ryan, C. G., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.030262 · Cited by 681
Qiu, S., Zhao, H., Jiang, N., Wang, Z., Liu, L., An, Y., Zhao, H., Miao, X., Liu, R., & Fortino, G. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.11.006 · Cited by 671
Accelerometry: A technique for quantifying movement patterns during walking
Kavanagh, J. J., & Menz, H. B. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2007.10.010 · Cited by 617
Metadata
- Authors
- Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2005-07-01
- Volume
- 27
- Issue
- 6
- Pages
- 497-504
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2086067762
- Cited by
- 218
- References
- 1
- FWCI
- 11.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A description of an accelerometer-based mobility monitoring technique. https://app.cochat.ai/papers/10.1016/j.medengphy.2004.11.006
- The paper
- Lyons, G. M., Culhane, K. M., Hilton, D., Grace, P. A., & Lyons, D. (2005). A description of an accelerometer-based mobility monitoring technique. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2004.11.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.