The DOI matches its Crossref record.
The material mapping strategy influences the accuracy of CT-based finite element models of bones: An evaluation against experimental measurements
Abstract
Aim of the present study was to evaluate the influence on the global model's accuracy of the strategy adopted to define the average element Young's modulus in subject-specific finite element models of bones from computed tomography data. The classic strategy of calculating the Young's modulus from an average element density and the one that averages the Young's moduli directly derived from each voxel Hounsfield Unit were considered. These strategies were applied to the finite element model of a real human femur. The accuracy of the superficial stress and strain predictions was evaluated against experimentally measured values in 13 strain-gauge locations for five different loading conditions. The results obtained for the two material distributions were statistically different. Both models predicted very accurately the superficial stresses, with regression coefficients higher than 0.9 and slopes not significantly different from unity. The second strategy definitely improved the strains prediction accuracy: the regression coefficient raised from 0.69 to 0.79; the average and peak errors decreased from 45.1% to 31.3% and from 228% to 134% of the maximum measured strain, respectively. The stress fields predicted inside the bone were also significantly different. A new software implementing the second strategy was made available in the public domain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ng, K. C. G., Lamontagne, M., Labrosse, M. R., & Beaulé, P. E. (2016) · PLoS ONE · doi:10.1371/journal.pone.0147813 · Cited by 54
Khayyeri, H., Väänänen, S. P., Flivik, G., Jurvelin, J. S., Dahlberg, L., & Isaksson, H. (2020) · Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization · doi:10.1080/21681163.2019.1578266
Metadata
- Authors
- Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2006-12-12
- Volume
- 29
- Issue
- 9
- Pages
- 973-979
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2121337876
- Cited by
- 339
- References
- 0
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The material mapping strategy influences the accuracy of CT-based finite element models of bones: An evaluation against experimental measurements. https://app.cochat.ai/papers/10.1016/j.medengphy.2006.10.014
- The paper
- Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007). The material mapping strategy influences the accuracy of CT-based finite element models of bones: An evaluation against experimental measurements. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2006.10.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.