Automated anatomical demarcation using an active shape model for videofluoroscopic analysis in swallowing
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The current gold standard method in the clinical assessment of swallowing is the visual inspection of videofluoroscopic frames. Specific clinical measurements are estimated based on various anatomical and bolus positional information with respect to time (or frame number). However, due to the subjective nature of visual inspection clinicians face intra- and inter-observer repeatability issues and bias when making these estimations. The correct demarcations of reference lines highlighting the positions of important anatomical landmarks would serve as a visual aid and could also be used in conjunction with bolus detection methods to objectively determine these desirable measurements. In this paper, we introduce and test the reliability of applying a 16-point Active Shape Model as a deformable template to demarcate the boundaries of salient anatomical boundaries with minimal user input. A robust end and corner point detection algorithm is also used to provide image information for the suggested movement of the template during the fitting stage. Results show the model deformation constraints calculated from a training set of images are clinically coherent. The Euclidean distances between the fitted model points against their corresponding target points were measured. Test images were taken from two different data sets from frames acquired using two different videofluoroscopy units. Overall, fitting was found to be more reliable on the vertebrae and inferior points of the larynx compared to the superior laryngeal points and hyoid bone, with the model always fitting the C7 vertebra with discrepancies no higher than a distance of 23 pixels (3.2% of the image width, approximately 7.6mm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dysphagia After Stroke: Incidence, Diagnosis, and Pulmonary Complications
Martino, R., Foley, N., Bhogal, S., Diamant, N., Speechley, M., & Teasell, R. (2005) · Stroke · doi:10.1161/01.str.0000190056.76543.eb · Cited by 1,973
Radiologic assessment of abnormal oral and pharyngeal phases of swallowing.
Dodds, W. J., Logemann, J. A., & Stewart, E. T. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.154.5.2108570 · Cited by 237
Interrater Reliability of Videofluoroscopic Swallow Evaluation
Stoeckli, S. J., Huisman, T. A. G. M., Seifert, B. A. G. M., & Martin-Harris, B. J. W. (2003) · Dysphagia · doi:10.1007/s00455-002-0085-0 · Cited by 198
Hyoid Movement During Swallowing in Older Patients With Dysphagia
Kendall, K. A., & Leonard, R. J. (2001) · Archives of Otolaryngology–Head & Neck Surgery · doi:10.1001/archotol.127.10.1224 · Cited by 127
Chang, M. W., Lin, E., & Hwang, J.-N. (1999) · Dysphagia · doi:10.1007/pl00009609 · Cited by 14 · cited 1×
“[5] used knowledge-based nakes to detect and segment the bolus in each frame.”
Method
Cited by
Oropharyngeal dysphagia: manifestations and diagnosis
Rommel, N., & Hamdy, S. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2015.199 · Cited by 272
Self-citationLee, J. T., Park, E., & Jung, T.-D. (2019) · Sensors · doi:10.3390/s19183873 · Cited by 30
Automatic detection of airway invasion from videofluoroscopy via deep learning technology
Lee, S. J., Ko, J. Y., Kim, H. I., & Choi, S.-I. (2020) · Applied Sciences · doi:10.3390/app10186179 · Cited by 28
“Aung et al. in another study attempted automatic demarcation of salient landmarks by applying a 16 point active shape model with high reliability; however, manual initialization was required to determine the co-ordinates of the reference points from the first frame of the video [10].”
MethodLee, D., Lee, W. H., Seo, H. G., Oh, B.-M., Lee, J. C., & Kim, H. C. (2020) · IEEE Access · doi:10.1109/access.2020.3019532 · Cited by 22
Bandini, A., Smaoui, S., & Steele, C. M. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107058 · Cited by 16
“For each model, the best combination of training parameters was chosen by testing all possible combinations of the following parameters: initial learning rate α0 = [1e-2, 1e-3, 1e-4, 1e-5]; batch size = [8, 16, 32]; optimizer = [SGD, RMSProp, Adam] [45].”
BackgroundMethod
Metadata
- Authors
- Aung, M. S. H., Goulermas, J. Y., Stanschus, S., Hamdy, S., & Power, M.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2010-09-19
- Volume
- 32
- Issue
- 10
- Pages
- 1170-1179
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2171882821
- Cited by
- 17
- References
- 5
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- publishingsupport.iopscience.iop.org/iop-standard/v1 (vor)
- iopscience.iop.org/info/page/text-and-data-mining (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.