CoChat

Automated anatomical demarcation using an active shape model for videofluoroscopic analysis in swallowing

Aung, M.S.H., Goulermas, J.Y., Stanschus, S., Hamdy, S., Power, M. · 2010 · Medical Engineering & Physics
Cited by 17

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The current gold standard method in the clinical assessment of swallowing is the visual inspection of videofluoroscopic frames. Specific clinical measurements are estimated based on various anatomical and bolus positional information with respect to time (or frame number). However, due to the subjective nature of visual inspection clinicians face intra- and inter-observer repeatability issues and bias when making these estimations. The correct demarcations of reference lines highlighting the positions of important anatomical landmarks would serve as a visual aid and could also be used in conjunction with bolus detection methods to objectively determine these desirable measurements. In this paper, we introduce and test the reliability of applying a 16-point Active Shape Model as a deformable template to demarcate the boundaries of salient anatomical boundaries with minimal user input. A robust end and corner point detection algorithm is also used to provide image information for the suggested movement of the template during the fitting stage. Results show the model deformation constraints calculated from a training set of images are clinically coherent. The Euclidean distances between the fitted model points against their corresponding target points were measured. Test images were taken from two different data sets from frames acquired using two different videofluoroscopy units. Overall, fitting was found to be more reliable on the vertebrae and inferior points of the larynx compared to the superior laryngeal points and hyoid bone, with the model always fitting the C7 vertebra with discrepancies no higher than a distance of 23 pixels (3.2% of the image width, approximately 7.6mm).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2010.08.008

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 17

Metadata

Authors
Aung, M. S. H., Goulermas, J. Y., Stanschus, S., Hamdy, S., & Power, M.
Venue
Medical Engineering & Physics
Published
2010-09-19
Volume
32
Issue
10
Pages
1170-1179
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2171882821
Cited by
17
References
5
FWCI
1.84
Type
journal article
Language
en
Open access
closed
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.