The DOI matches its Crossref record.
Optimization of scaffold design for bone tissue engineering: A computational and experimental study
Abstract
In bone tissue engineering, the scaffold has not only to allow the diffusion of cells, nutrients and oxygen but also provide adequate mechanical support. One way to ensure the scaffold has the right properties is to use computational tools to design such a scaffold coupled with additive manufacturing to build the scaffolds to the resulting optimized design specifications. In this study a topology optimization algorithm is proposed as a technique to design scaffolds that meet specific requirements for mass transport and mechanical load bearing. Several micro-structures obtained computationally are presented. Designed scaffolds were then built using selective laser sintering and the actual features of the fabricated scaffolds were measured and compared to the designed values. It was possible to obtain scaffolds with an internal geometry that reasonably matched the computational design (within 14% of porosity target, 40% for strut size and 55% for throat size in the building direction and 15% for strut size and 17% for throat size perpendicular to the building direction). These results support the use of these kind of computational algorithms to design optimized scaffolds with specific target properties and confirm the value of these techniques for bone tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design for Additive Manufacturing: Trends, opportunities, considerations, and constraints
Thompson, M. K., Moroni, G., Vaneker, T., Fadel, G., Campbell, R. I., Gibson, I., Bernard, A., Schulz, J., Graf, P., Ahuja, B., et al. (2016) · CIRP Annals · doi:10.1016/j.cirp.2016.05.004 · Cited by 2,017
Current state of fabrication technologies and materials for bone tissue engineering
Wubneh, A., Tsekoura, E. K., Ayranci, C., & Uludağ, H. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.09.031 · Cited by 584
Nazir, A., Abate, K. M., Kumar, A., & Jeng, J.-Y. (2019) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-019-04085-3 · Cited by 528
Support Structures for Additive Manufacturing: A Review
Jiang, J., Xu, X., & Stringer, J. (2018) · Journal of Manufacturing and Materials Processing · doi:10.3390/jmmp2040064 · Cited by 527
Amin Yavari, S., Ahmadi, S. M., Wauthle, R., Pouran, B., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.12.015 · Cited by 431
Metadata
- Authors
- Dias, M. R., Guedes, J. M., Flanagan, C. L., Hollister, S. J., & Fernandes, P. R.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2014-03-11
- Volume
- 36
- Issue
- 4
- Pages
- 448-457
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2042581802
- Cited by
- 171
- References
- 0
- FWCI
- 29.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of scaffold design for bone tissue engineering: A computational and experimental study. https://app.cochat.ai/papers/10.1016/j.medengphy.2014.02.010
- The paper
- Dias, M. R., Guedes, J. M., Flanagan, C. L., Hollister, S. J., & Fernandes, P. R. (2014). Optimization of scaffold design for bone tissue engineering: A computational and experimental study. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2014.02.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.