Improved inference in Bayesian segmentation using Monte Carlo sampling: Application to hippocampal subfield volumetry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Many segmentation algorithms in medical image analysis use Bayesian modeling to augment local image appearance with prior anatomical knowledge. Such methods often contain a large number of free parameters that are first estimated and then kept fixed during the actual segmentation process. However, a faithful Bayesian analysis would marginalize over such parameters, accounting for their uncertainty by considering all possible values they may take. Here we propose to incorporate this uncertainty into Bayesian segmentation methods in order to improve the inference process. In particular, we approximate the required marginalization over model parameters using computationally efficient Markov chain Monte Carlo techniques. We illustrate the proposed approach using a recently developed Bayesian method for the segmentation of hippocampal subfields in brain MRI scans, showing a significant improvement in an Alzheimer’s disease classification task. As an additional benefit, the technique also allows one to compute informative “error bars” on the volume estimates of individual structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image registration methods: a survey
Zitová, B., & Flusser, J. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00137-9 · Cited by 6,423
On the Statistical Analysis of Dirty Pictures
Besag, J. (1986) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1986.tb01412.x · Cited by 4,191
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Automated segmentation of hippocampal subfields from ultra‐high resolution in vivo MRI
Van Leemput, K., Bakkour, A., Benner, T., Wiggins, G., Wald, L. L., Augustinack, J., Dickerson, B. C., Golland, P., & Fischl, B. (2009) · Hippocampus · doi:10.1002/hipo.20615 · Cited by 405 · cited 7×
“We instantiate the approach within a recently proposed Bayesian method aiming to segment hippocampal subfields in brain MRI scans (Van Leemput et al., 2009), and show that MCMC sampling yields hippocampal subfield volume estimates that better discriminate controls from subjects with Alzheimer’s…”
InfluentialHippocampal atrophy patterns in mild cognitive impairment and Alzheimer's disease
Mueller, S. G., Schuff, N., Yaffe, K., Madison, C., Miller, B., & Weiner, M. W. (2010) · Human Brain Mapping · doi:10.1002/hbm.20934 · Cited by 361 · cited 2×
“Automatic segmentation of the subfields has recently attracted the interest of the neuroscience community because different regions of the hippocampal formation are affected differently by normal aging and Alzheimer’s disease (Mueller et al., 2010; Yushkevich et al., 2010).”
Cited by
Iglesias, J. E., Augustinack, J. C., Nguyen, K., Player, C. M., Player, A., Wright, M., Roy, N., Frosch, M. P., McKee, A. C., Wald, L. L., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.04.042 · Cited by 1,277
Self-citationMulti-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
“This model has been extended to inter-modality fusion (Iglesias et al., 2013b), replacing the Gaussian noise by a joint histogram; and to patch-based fusion (Bai et al., 2013), by augmenting M with a spatial shift and defining the intensity likelihood term as a function of patches.”
BackgroundMethodInfluentialSelf-citationYushkevich, P. A., Pluta, J. B., Wang, H., Xie, L., Ding, S.-L., Gertje, E. C., Mancuso, L., Kliot, D., Das, S. R., & Wolk, D. A. (2015) · Human Brain Mapping · doi:10.1002/hbm.22627 · Cited by 599
Zöllei, L., Iglesias, J. E., Ou, Y., Grant, P. E., & Fischl, B. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116946 · Cited by 204
“Compared with [85, 86], a key difference is that some of our atlases do not provide”
Self-citationIglesias, J. E., Van Leemput, K., Augustinack, J., Insausti, R., Fischl, B., & Reuter, M. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.07.020 · Cited by 174
“However, the potential gain would be minimal because there are sufficient voxels in each time point to estimate h t with high certainty (Iglesias et al., 2013).”
BackgroundSelf-citation
Metadata
- Authors
- Iglesias, J. E., Sabuncu, M. R., & Van Leemput, K.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2013-10
- Volume
- 17
- Issue
- 7
- Pages
- 766-778
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2104465614
- Cited by
- 37
- References
- 5
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.