Real-time simulation of contact and cutting of heterogeneous soft-tissues
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
This paper presents a numerical method for interactive (real-time) simulations, which considerably improves the accuracy of the response of heterogeneous soft-tissue models undergoing contact, cutting and other topological changes. We provide an integrated methodology able to deal both with the ill-conditioning issues associated with material heterogeneities, contact boundary conditions which are one of the main sources of inaccuracies, and cutting which is one of the most challenging issues in interactive simulations. Our approach is based on an implicit time integration of a non-linear finite element model. To enable real-time computations, we propose a new preconditioning technique, based on an asynchronous update at low frequency. The preconditioner is not only used to improve the computation of the deformation of the tissues, but also to simulate the contact response of homogeneous and heterogeneous bodies with the same accuracy. We also address the problem of cutting the heterogeneous structures and propose a method to update the preconditioner according to the topological modifications. Finally, we apply our approach to three challenging demonstrators: (i) a simulation of cataract surgery (ii) a simulation of laparoscopic hepatectomy (iii) a brain tumor surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zienkiewicz, O. C. (1989) · Cited by 14,802
Iterative Methods for Sparse Linear Systems
Saad, Y. (2003) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898718003 · Cited by 13,790 · cited 1×
“…such that jðP 1AÞ < jðAÞ ð15Þ In the real-time context, one strong limitation of this technique is the computational overhead added to the simulation: first, during the computation of the preconditioner itself, and second, during its use at each iteration of the CG (see Saad (2003) for details).”
MethodA finite element method for crack growth without remeshing
Mo�s, N., Dolbow, J., & Belytschko, T. (1999) · International Journal for Numerical Methods in Engineering · doi:10.1002/(sici)1097-0207(19990910)46:1<131::aid-nme726>3.0.co;2-j · Cited by 6,446 · cited 1×
“Alternatives to generating finite element meshes, in particular to handle topological changes are extended finite element methods (Nicolas et al., 1999).”
BackgroundThe finite element method. Linear static and dynamic finite element analysis
Zimmermann, T. (1987) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(87)90013-2 · Cited by 5,080
The Finite Element Method: Linear Static and Dynamic Finite Element Analysis
Hughes, T. J. R. (1987) · Cited by 4,852
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Templates for the Solution of Linear Systems: Building Blocks for Iterative Methods
Barrett, R., Berry, M., Chan, T. F., Demmel, J., Donato, J., Dongarra, J., Eijkhout, V., Pozo, R., Romine, C., & van der Vorst, H. (1994) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971538 · Cited by 3,479
Large steps in cloth simulation
Baraff, D., & Witkin, A. (1998) · Proceedings of the 25th annual conference on Computer graphics and interactive techniques - SIGGRAPH '98 · doi:10.1145/280814.280821 · Cited by 1,684 · cited 3×
“Providing flexibility in the choice of the time step, even for very stiff objects (Baraff and Witkin, 1998), is required to achieve our aim: simulate usercontrolled interactions between arbitrarily stiff anatomical structures or tools.”
BackgroundMethodInfluentialSynthesis and evaluation of linear motion transitions
Wang, J., & Bodenheimer, B. (2008) · ACM Transactions on Graphics · doi:10.1145/1330511.1330512 · Cited by 1,534
The non-smooth contact dynamics method
Jean, M. (1999) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)00383-1 · Cited by 924 · cited 1×
“Lagrange multipliers or augmented Lagrangian techniques (Hughes, 2000; Renard, 2013; Jean, 1999; Jourdan et al., 1998; Wriggers and Panatiotopoulos, 1999) are usually preferred to penalty methods to treat contact constraints accurately and robustly.”
Background
Cited by
On the use of simulation in robotics: Opportunities, challenges, and suggestions for moving forward
Choi, H., Crump, C., Duriez, C., Elmquist, A., Hager, G., Han, D., Hearl, F., Hodgins, J., Jain, A., Leve, F., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1907856118 · Cited by 162
Metadata
- Authors
- Courtecuisse, H., Allard, J., Kerfriden, P., Bordas, S. P. A., Cotin, S., & Duriez, C.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 18
- Issue
- 2
- Pages
- 394-410
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W1979987057
- Cited by
- 166
- References
- 50
- FWCI
- 9.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time simulation of contact and cutting of heterogeneous soft-tissues. https://app.cochat.ai/papers/10.1016/j.media.2013.11.001
- The paper
- Courtecuisse, H., Allard, J., Kerfriden, P., Bordas, S. P. A., Cotin, S., & Duriez, C. (2014). Real-time simulation of contact and cutting of heterogeneous soft-tissues. Medical Image Analysis. https://doi.org/10.1016/j.media.2013.11.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.