The reliability of a deep learning model in clinical out-of-distribution MRI data: A multicohort study
Open accessAbstract
Deep learning (DL) methods have in recent years yielded impressive results in medical imaging, with the potential to function as clinical aid to radiologists. However, DL models in medical imaging are often trained on public research cohorts with images acquired with a single scanner or with strict protocol harmonization, which is not representative of a clinical setting. The aim of this study was to investigate how well a DL model performs in unseen clinical datasets-collected with different scanners, protocols and disease populations-and whether more heterogeneous training data improves generalization. In total, 3117 MRI scans of brains from multiple dementia research cohorts and memory clinics, that had been visually rated by a neuroradiologist according to Scheltens' scale of medial temporal atrophy (MTA), were included in this study. By training multiple versions of a convolutional neural network on different subsets of this data to predict MTA ratings, we assessed the impact of including images from a wider distribution during training had on performance in external memory clinic data. Our results showed that our model generalized well to datasets acquired with similar protocols as the training data, but substantially worse in clinical cohorts with visibly different tissue contrasts in the images. This implies that future DL studies investigating performance in out-of-distribution (OOD) MRI data need to assess multiple external cohorts for reliable results. Further, by including data from a wider range of scanners and protocols the performance improved in OOD data, which suggests that more heterogeneous training data makes the model generalize better. To conclude, this is the most comprehensive study to date investigating the domain shift in deep learning on MRI data, and we advocate rigorous evaluation of DL models on clinical data prior to being certified for deployment.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Machine learning models have concerning out-of-sample generalizability on data from sources that did not participate in model training.
“Although machine learning (ML) has shown promise across disciplines, out-of-sample generalizability is concerning.”
From Federated learning enables big data for rare cancer boundary detection (2022) · cites this paper as [1]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 40 · Cited by 176
Research works printed but not linked: 1
- Orbes-Arteaga, M. , Varsavsky, T. , Sudre, C.H. , Eaton-Rosen, Z. , Haddow, L.J. , Sørensen, L. , Nielsen, M. , Pai, A. , Ourselin, S. , Modat, M. , Nachev, P. , Cardoso, M.J. , 2019. Multi-Domain Adaptation in Brain MRI through Paired Consistency and Adversarial Learning. In: Multi-Domain Adaptation in Brain MRI through Paired Consistency and Adversarial Learning. DART, 11795, pp. 54-62 . 1908.05959.
- Authors
- Mårtensson, G., Ferreira, D., Granberg, T., Cavallin, L., Oppedal, K., Padovani, A., Rektorova, I., Bonanni, L., Pardini, M., Kramberger, M. G., Taylor, J.-P., Hort, J., Snædal, J., Kulisevsky, J., Blanc, F., Antonini, A., Mecocci, P., Vellas, B., Tsolaki, M., Kłoszewska, I., Soininen, H., Lovestone, S., Simmons, A., Aarsland, D., & Westman, E.
- Affiliations
- Karolinska Institutet (SE)
- Karolinska University Hospital (SE)
- Stavanger University Hospital (NO)
- University of Brescia (IT)
- University of Chieti-Pescara (IT)
- Ospedale Policlinico San Martino (IT)
- University of Ljubljana (SI)
- University of Newcastle Australia (AU)
- Charles University (CZ)
- National University Hospital of Iceland (IS)
- Universitat Autònoma de Barcelona (ES)
- University of Padua (IT)
- University of Perugia (IT)
- Inserm (FR)
- Aristotle University of Thessaloniki (GR)
- Medical University of Lodz (PL)
- University of Eastern Finland (FI)
- Warneford Hospital (GB)
- King's College London (GB)
- Corresponding author
- Mårtensson, Gustav
- ORCID
- Mårtensson, Gustav
- Ferreira, Daniel
- Granberg, Tobias
- Cavallin, Lena
- Oppedal, Ketil
- Padovani, Alessandro
- Bonanni, Laura
- Pardini, Matteo
- Kramberger, Milica G
- Taylor, John-Paul
- Hort, Jakub
- Snædal, Jón
- Kulisevsky, Jaime
- Antonini, Angelo
- Mecocci, Patrizia
- Vellas, Bruno
- Tsolaki, Magda
- Soininen, Hilkka
- Lovestone, Simon
- Simmons, Andrew
- Aarsland, Dag
- Westman, Eric
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 66
- Pages
- 101714
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W3023773746
- Cited by
- 176
- References
- 40
- Citations by year
- 2026: 20 · 2025: 30 · 2024: 32 · 2023: 31 · 2022: 34 · 2021: 23 · 2020: 6
- FWCI
- 17.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Medical Image Analysis (publishedVersion, cc-by)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- HAL (submittedVersion, cc-by)
- Dipòsit Digital de Documents de la UAB (Universitat Autònoma de Barcelona) (submittedVersion, cc-by)
- CINECA IRIS Institutial Research Information System (University of Genoa) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
- Hirsla (Landspítali University Hospital) (submittedVersion)
- Padua Research Archive (University of Padova) (submittedVersion, cc-by)
- arXiv (Cornell University)
- Funders
- Alzheimer’s Disease Neuroimaging Initiative
- National Institutes of Health (U01 AG024904)
- DOD ADNI
- Department of Defense (W81XWH-12-2-0012)
- ADNI
- National Institute on Aging
- Topics
- Health Sciences › Medicine › Psychiatry and Mental health › Dementia and Cognitive Impairment Research
- Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- out-of-distribution generalization, domain shift, magnetic resonance imaging, medial temporal lobe atrophy, dementia, convolutional neural networks, brain MRI, external validation, model reliability, Scheltens scale
- MeSH terms
- Deep Learning, Brain, Humans, Magnetic Resonance Imaging, Reproducibility of Results, Neural Networks, Computer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review