Abstract

PET imaging involves radiotracer injections, raising concerns about the risk of radiation exposure. To minimize the potential risk, one way is to reduce the injected tracer. However, this will lead to poor image quality with conventional image reconstruction and processing. In this paper, we proposed a supervised deep learning model, CycleWGANs, to boost low-dose PET image quality. Validations were performed on a low dose dataset simulated from a real dataset with biopsy-proven primary lung cancer or suspicious radiological abnormalities. Low dose PET images were reconstructed on reduced PET raw data by randomly discarding events in the PET list mode data towards the count level of 1 million. Traditional image denoising methods (Non-Local Mean (NLM) and block-matching 3D(BM3D)) and two recently-published deep learning methods (RED-CNN and 3D-cGAN) were included for comparisons. At the count level of 1 million (true counts), the proposed model can accurately estimate full-dose PET image from low-dose input image, which is superior to the other four methods in terms of the mean and maximum standardized uptake value (SUVmean and SUVmax) bias for lesions and normal tissues. The bias of SUV (SUVmean, SUVmax) for lesions and normal tissues are (-2.06±3.50%,-0.84±6.94%) and (-0.45±5.59%, N/A) in the estimated PET images, respectively. However, the RED-CNN achieved the best score in traditional metrics, such as structure similarity (SSIM), peak signal to noise ratio (PSNR) and normalized root mean square error (NRMSE). Correlation and profile analyses have successfully explained this phenomenon and further suggested that our method could effectively preserve edge and also SUV values than RED-CNN, 3D-cGAN and NLM with a slightly higher noise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2020.101770

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 203

Metadata

Authors
Zhou, L., Schaefferkoetter, J. D., Tham, I. W. K., Huang, G., & Yan, J.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2020-10
Volume
65
Pages
101770
ISSN
1361-8415 (ISSN-L)
OpenAlex
W3041500444
Cited by
203
References
11
FWCI
10.03
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.