CoChat

High-resolution 3D abdominal segmentation with random patch network fusion

Open access
Tang, Yucheng, Gao, Riqiang, Lee, Ho Hin, Han, Shizhong, Chen, Yunqiang, Gao, Dashan, Nath, Vishwesh, Bermudez, Camilo, Savona, Michael R., Abramson, Richard G., Bao, Shunxing, Lyu, Ilwoo, Huo, Yuankai, Landman, Bennett A. · 2021 · Medical Image Analysis
Cited by 67

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Deep learning for three dimensional (3D) abdominal organ segmentation on high-resolution computed tomography (CT) is a challenging topic, in part due to the limited memory provide by graphics processing units (GPU) and large number of parameters and in 3D fully convolutional networks (FCN). Two prevalent strategies, lower resolution with wider field of view and higher resolution with limited field of view, have been explored but have been presented with varying degrees of success. In this paper, we propose a novel patch-based network with random spatial initialization and statistical fusion on overlapping regions of interest (ROIs). We evaluate the proposed approach using three datasets consisting of 260 subjects with varying numbers of manual labels. Compared with the canonical “coarse-to-fine” baseline methods, the proposed method increases the performance on multi-organ segmentation from 0.799 to 0.856 in terms of mean DSC score (p-value < 0.01 with paired t-test). The effect of different numbers of patches is evaluated by increasing the depth of coverage (expected number of patches evaluated per voxel). In addition, our method outperforms other state-of-the-art methods in abdominal organ segmentation. In conclusion, the approach provides a memory-conservative framework to enable 3D segmentation on high-resolution CT. The approach is compatible with many base network structures, without substantially increasing the complexity during inference. Given a CT scan with at high resolution, a low-res section (left panel) is trained with multi-channel segmentation. The low-res part contains down-sampling and normalization in order to preserve the complete spatial information. Interpolation and random patch sampling (mid panel) is employed to collect patches. The highdimensional probability maps are acquired (right panel) from integration of all patches on field of views.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.media.2020.101894

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 67

Metadata

Authors
Tang, Y., Gao, R., Lee, H. H., Han, S., Chen, Y., Gao, D., Nath, V., Bermudez, C., Savona, M. R., Abramson, R. G., Bao, S., Lyu, I., Huo, Y., & Landman, B. A.
Venue
Medical Image Analysis
Publisher
Elsevier BV
Published
2021-04
Volume
69
Pages
101894
ISSN
1361-8415 (ISSN-L)
OpenAlex
W3112256294
Cited by
67
References
12
FWCI
2.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.