The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Adsorption of heavy metal ions by mesoporous ZnO and TiO2@ZnO monoliths: Adsorption and kinetic studies
Abstract
Abstract Up till now, the excessive and unconstrained release of Pb2+ and Cd2+ ions in water becomes a foremost concern by way of threatening human health seriously. Therefore, for removal of heavy metal ions from waste water, adsorbent with high efficacy and low-cost technologies is most needed to alleviate the situation. In this work, robust, mesoporous ZnO & TiO2@ZnO monoliths with the valuable surface area (120–332 m2/g) were synthesized via nanocasting process and their performance as an adsorbent for removal of heavy metal (Pb2+ and Cd2+) ions from aqueous water was successfully evaluated. The adsorption data shows better fit at pH 6 to Freundlich isotherm model. Applicability of pseudo-second order (PSO) kinetic model specifies the chemisorption process. Thermodynamic parameters confirmed that removal of Pb2+ and Cd2+ ions was an endothermic process. The maximum adsorption efficacy of Pb2+ ions based on monolayer adsorption was found to be 790 and 978 mg/L for ZnO and TiO2@ZnO monoliths, respectively whereas the maximum adsorption efficacy of Cd2+ ions based on monolayer adsorption was found to be 643 and 786 mg/L for ZnO and TiO2@ZnO monoliths respectively. Besides, used mesoporous ZnO & TiO2@ZnO monoliths could be efficiently reused for at least three times after treatment with NaOH. The high uptake capacity for Pb2+ and Cd2+ ions with good reusability of ZnO & TiO2@ZnO monoliths made them a potentially attractive adsorbent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of Heavy Metals by Waste Tea Leaves from Aqueous Solution
Ahluwalia, S. S., & Goyal, D. (2005) · Engineering in Life Sciences · doi:10.1002/elsc.200420066 · Cited by 374
Cited by
Vardhan, K. H., Kumar, P. S., & Panda, R. C. (2019) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.111197 · Cited by 1,618
Gupta, K., Joshi, P., Gusain, R., & Khatri, O. P. (2021) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214100 · Cited by 331
Photocatalysis vs adsorption by metal oxide nanoparticles
Qumar, U., Hassan, J. Z., Bhatti, R. A., Raza, A., Nazir, G., Nabgan, W., & Ikram, M. (2022) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2022.05.020 · Cited by 262
Metadata
- Authors
- Sharma, M., Singh, J., Hazra, S., & Basu, S.
- Venue
- Microchemical Journal
- Publisher
- Elsevier BV
- Published
- 2019-03
- Volume
- 145
- Pages
- 105-112
- ISSN
- 0026-265X (ISSN-L)
- OpenAlex
- W2896888799
- Cited by
- 185
- References
- 1
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adsorption of heavy metal ions by mesoporous ZnO and TiO2@ZnO monoliths: Adsorption and kinetic studies. https://app.cochat.ai/papers/10.1016/j.microc.2018.10.026
- The paper
- Sharma, M., Singh, J., Hazra, S., & Basu, S. (2019). Adsorption of heavy metal ions by mesoporous ZnO and TiO2@ZnO monoliths: Adsorption and kinetic studies. Microchemical Journal. https://doi.org/10.1016/j.microc.2018.10.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.