The DOI matches its Crossref record; 186 of the 186 references it cites were found in a registry or an index.
Miniaturized solid-phase extraction techniques in sample preparation applied to food matrices: A review
Open accessAbstract
Sample preparation is a critical step in analytical workflows, especially in food analysis, where complex matrices require efficient and reliable extraction techniques. Traditionally, methods such as liquid–liquid extraction have been widely used. However, the growing need for greener and more sustainable approaches has shifted the focus toward solid-phase extraction (SPE). In recent years, miniaturized SPE techniques have emerged as a powerful alternative, offering reduced sample and solvent consumption, simplified workflows, and compatibility with modern analytical platforms. This review explores the development and application of miniaturized SPE methods in food analysis, discussing key advances, advantages over traditional techniques, and remaining challenges. The solid-phase miniaturized techniques covered include solid-phase microextraction, stir-bar sorptive extraction, magnetic solid-phase extraction, immunoaffinity solid-phase extraction, microextraction by packed sorbent, molecularly imprinted solid-phase extraction, and dispersive micro-solid-phase extraction. By summarizing the literature and providing a critical overview of these approaches, this work highlights the potential of miniaturized SPE as a cornerstone for innovative and sustainable food analysis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These miniaturized platforms significantly reduce solvent consumption and support continuous-flow extraction, making them highly useful for real-time environmental and clinical monitoring [106].”
From Eco-Friendly Deep Eutectic Solvent-Based Extraction Technologies: A Comprehensive Review of Principles, Applications, and Comparative Insights (2026) · cites this paper as [106]
Citations
Cites
CHEM21 selection guide of classical- and less classical-solvents
Prat, D., Wells, A., Hayler, J., Sneddon, H., McElroy, C. R., Abou-Shehada, S., & Dunn, P. J. (2016) · Green Chemistry · doi:10.1039/c5gc01008j · Cited by 2,215
Manousi, N., Wojnowski, W., Płotka-Wasylka, J., & Samanidou, V. (2023) · Green Chemistry · doi:10.1039/d3gc02347h · Cited by 1,685
Miniaturized solid-phase extraction techniques
Płotka-Wasylka, J., Szczepańska, N., de la Guardia, M., & Namieśnik, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.026 · Cited by 517
Magnetic materials as sorbents for metal/metalloid preconcentration and/or separation. A review
Giakisikli, G., & Anthemidis, A. N. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.04.021 · Cited by 449
Development of dispersive micro-solid phase extraction based on micro and nano sorbents
Khezeli, T., & Daneshfar, A. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.01.004 · Cited by 327
Recent advances and trends in miniaturized sample preparation techniques
Soares da Silva Burato, J., Vargas Medina, D. A., de Toffoli, A. L., Vasconcelos Soares Maciel, E., & Mauro Lanças, F. (2020) · Journal of Separation Science · doi:10.1002/jssc.201900776 · Cited by 254
Ishizaki, A., Saito, K., Hanioka, N., Narimatsu, S., & Kataoka, H. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.068 · Cited by 209
Câmara, J. S., Perestrelo, R., Berenguer, C. V., Andrade, C. F. P., Gomes, T. M., Olayanju, B., Kabir, A., M. R. Rocha, C., Teixeira, J. A., & Pereira, J. A. M. (2022) · Molecules · doi:10.3390/molecules27092953 · Cited by 199
Vuran, B., Ulusoy, H. İ., Sarp, G., Yılmaz, E., MORGÜL, Ü., Kabir, A., Tartaglia, A., Locatelli, M., & Soylak, M. (2021) · Talanta · doi:10.1016/j.talanta.2021.122307 · Cited by 155
Green miniaturized technologies in analytical and bioanalytical chemistry
Agrawal, A., Keçili, R., Ghorbani‐Bidkorbeh, F., & Hussain, C. M. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116383 · Cited by 144
Research works printed but not linked: 3
- Botrel, 2019, Development, optimization, and validation of the HS-SPME/GC-MS method for the residual determination of menthol in fish, Food Anal, Methods, 12, 1390
- Machyňáková, 2017, Preparation and application of magnetic molecularly imprinted polymers for the selective extraction of coumarins from food and plant samples, Anal, Methods, 9, 2168
- Mohammadi Nilash, 2019, Novel Schiff base-functionalized metal-organic framework nanoparticles for dispersive solid phase extraction of copper ions from vegetable and water samples, Anal, Methods, 11, 2683
Cited by
Mnyango, J. I., Nyoni, B., Phiri, C., Fouda-Mbanga, B. G., Amusat, S. O., Maringa, A., Yalala-Ndlovu, B., Hlabano-Moyo, B. M., Tywabi-Ngeva, Z., & Hlangothi, S. P. (2025) · Next Materials · doi:10.1016/j.nxmate.2025.100974 · Cited by 58
Alves, E., Gurupadayya, B., & Prabhakaran, P. (2025) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2553122 · Cited by 22
Iglesias-Martín, C., Ares, A. M., Bernal, J., & Fuente-Ballesteros, A. (2025) · Talanta · doi:10.1016/j.talanta.2025.128608 · Cited by 8
Self-citationResearch advances in sample pretreatment techniques for pesticide residues
Cui, J., & Dong, F. (2025) · Journal of Chromatography Open · doi:10.1016/j.jcoa.2025.100259 · Cited by 12
Microbial degradation of persistent organic pollutants in food supply chain
Kumar, P., Singh, A. K., Tripathi, M., Diwan, D., Manimekalai, R., Sharma, M., Jogaiah, S., Dubey, R. C., & Sharma, G. D. (2025) · Discover Food · doi:10.1007/s44187-025-00569-2 · Cited by 9
Metadata
- Authors
- Jano, A., Fuente-Ballesteros, A., Ares, A. M., & Bernal, J.
- Affiliations
- Universidad de Valladolid (ES)
- Corresponding author
- Bernal, José
- Venue
- Microchemical Journal
- Publisher
- Elsevier BV
- Published
- 2025-06
- Volume
- 213
- Pages
- 113794
- ISSN
- 0026-265X (ISSN-L)
- OpenAlex
- W4409855046
- Cited by
- 48
- References
- 186
- Citations by year
- 2026: 29 · 2025: 19
- FWCI
- 3.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Locations
- Microchemical Journal (publishedVersion, cc-by-nc-nd)
- UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) (submittedVersion, cc-by-nc-nd)
- Funders
- Federación Española de Enfermedades Raras
- European Commission
- Agencia Estatal de Investigacion (PID2022-141679OR-C33)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- sample preparation, food analysis, solid-phase microextraction, stir bar sorptive extraction, magnetic solid-phase extraction, microextraction by packed sorbent, molecularly imprinted solid-phase extraction, dispersive micro-solid phase extraction, green analytical chemistry, food matrix
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Miniaturized solid-phase extraction techniques in sample preparation applied to food matrices: A review. https://app.cochat.ai/papers/10.1016/j.microc.2025.113794
- The paper
- Jano, A., Fuente-Ballesteros, A., Ares, A. M., & Bernal, J. (2025). Miniaturized solid-phase extraction techniques in sample preparation applied to food matrices: A review. Microchemical Journal. https://doi.org/10.1016/j.microc.2025.113794
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.