A standard method to obtain the mesopore size distribution of adsorbents is the Barrett, Joyner and Halenda (BJH) analysis of the N2 adsorption–desorption isotherm at 77 K. The availability, over the last two decades, of well-defined model adsorbents in the mesopore range, together with other forms of isotherm analysis with the help of the Density Functional Theory (DFT) has shown that the BJH method tended to underestimate the pore-width when they are smaller than 10 nm. Regarding this fact, we have reported an improved BJH method, where we have remarked that the reconstruction of the adsorption–desorption isotherm from the BJH results leads to some inconsistency. We therefore proposed a simple means to cancel the mentioned discrepancy and inconsistency. This correction can be made by simply adding a corrective term to the standard BJH equation, which value is selected to meet a self-consistent criterion, i.e. the reconstructed isotherm should fit the original one. In the first article, the method was applied for some ordered mesoporous materials (OMM) synthesized in our laboratory, showing only the results without major details. In this work, we validate the test for other samples, in other pore size ranges, introducing some remarks in theoretical aspects and in the importance of obtaining and taking into account the micropore volume. Finally, a detailed procedure to apply the proposal method using only the experimental data of the analysis is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of Gases in Multimolecular Layers
Brunauer, S., Emmett, P. H., & Teller, E. (1938) · Journal of the American Chemical Society · doi:10.1021/ja01269a023 · Cited by 28,156
Cited by
Liu, N., Charrua, A. B., Weng, C.-H., Yuan, X., & Ding, F. (2015) · Bioresource Technology · doi:10.1016/j.biortech.2015.08.129 · Cited by 281
Metadata
- Authors
- Villarroel-Rocha, J., Barrera, D., & Sapag, K.
- Venue
- Microporous and Mesoporous Materials
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 200
- Pages
- 68-78
- ISSN
- 1387-1811 (ISSN-L)
- OpenAlex
- W2090516669
- Cited by
- 199
- References
- 1
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Introducing a self-consistent test and the corresponding modification in the Barrett, Joyner and Halenda method for pore-size determination. https://app.cochat.ai/papers/10.1016/j.micromeso.2014.08.017
- The paper
- Villarroel-Rocha, J., Barrera, D., & Sapag, K. (2014). Introducing a self-consistent test and the corresponding modification in the Barrett, Joyner and Halenda method for pore-size determination. Microporous and Mesoporous Materials. https://doi.org/10.1016/j.micromeso.2014.08.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.