The DOI matches its Crossref record.
Optimization of electrocoagulation process for efficient removal of ciprofloxacin antibiotic using iron electrode; kinetic and isotherm studies of adsorption
Abstract
The present study focused on the removal of ciprofloxacin from hospital wastewater using electrocoagulation (EC) process by iron electrode and the kinetic and isotherms of adsorption were investigated. Response surface methodology (RSM) was used to evaluate the main effects of parameters, their simultaneous interactions and quadratic effect to achieve the optimum condition for EC process. The maximum removal rate was achieved at the current density of 15 mA·cm− 2, initial CIP concentration of 60 mg·L− 1, pH 7.5, inter-electrode distance 1.58 cm and electrolyte dose of 0.07 M NaCl within the equilibrium time of 20 min. The obtained experimental results are in good accordance with the Langmuir isotherm model for CIP adsorption on iron hydroxide by predicting the maximum adsorption capacity of 476.19 mg·g− 1. The predicted model for treatment of synthetic wastewater is in satisfactory agreement with real hospital wastewater treatment. First and second order kinetic models were studied to figure out the exact mechanism of the CIP removal using EC process. The obtained results revealed that the second order kinetic model best fitted the experimental results and suggested that the chemisorption mechanism controlled the adsorption of CIP. Under the optimal conditions of EC process, electrode consumption (ELC) and electrical energy consumption (EEC) were found to be 0.0625 g during a single run and 0.522 kWh·m− 3, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Adsorption of ciprofloxacin from water: A comprehensive review
Igwegbe, C. A., Oba, S. N., Aniagor, C. O., Adeniyi, A. G., & Ighalo, J. O. (2021) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2020.09.023 · Cited by 441
Zaied, B. K., Rashid, M., Nasrullah, M., Zularisam, A. W., Pant, D., & Singh, L. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.138095 · Cited by 328
Liang, C., Zhang, X., Feng, P., Chai, H., & Huang, Y. (2018) · Chemical Engineering Journal · doi:10.1016/j.cej.2018.03.064 · Cited by 288
Malakootian, M., Nasiri, A., & Amiri Gharaghani, M. (2020) · Chemical Engineering Communications · doi:10.1080/00986445.2019.1573168 · Cited by 254
Ahmadzadeh, S., Asadipour, A., Pournamdari, M., Behnam, B., Rahimi, H. R., & Dolatabadi, M. (2017) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2017.04.026 · Cited by 253
Self-citation
Metadata
- Authors
- Yoosefian, M., Ahmadzadeh, S., Aghasi, M., & Dolatabadi, M.
- Venue
- Journal of Molecular Liquids
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 225
- Pages
- 544-553
- ISSN
- 0167-7322 (ISSN-L)
- OpenAlex
- W2557430722
- Cited by
- 195
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of electrocoagulation process for efficient removal of ciprofloxacin antibiotic using iron electrode; kinetic and isotherm studies of adsorption. https://app.cochat.ai/papers/10.1016/j.molliq.2016.11.093
- The paper
- Yoosefian, M., Ahmadzadeh, S., Aghasi, M., & Dolatabadi, M. (2017). Optimization of electrocoagulation process for efficient removal of ciprofloxacin antibiotic using iron electrode; kinetic and isotherm studies of adsorption. Journal of Molecular Liquids. https://doi.org/10.1016/j.molliq.2016.11.093
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.