CoChat

Synthesis, characterization and adsorption studies of amino functionalized silica nano hollow sphere as an efficient adsorbent for removal of imidacloprid pesticide

Kalhor, Mozhgan Moradi, Rafati, Amir Abbas, Rafati, Lida, Rafati, Amir Ali · 2018 · Journal of Molecular Liquids
Cited by 87

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In the present research, silica nano hollow sphere (SNHS) and amino functionalized silica nano hollow sphere (SNHS-NH2) adsorbents have been used to remove imidacloprid as a high consumption pesticides from aqueous solutions. SNHS and SNHS-NH2 have been synthesized based on our previously reported methods. FT-IR and SEM techniques have been employed to analyze physicochemical characteristics of produced adsorbents. The adsorption of imidacloprid has been evaluated in terms of kinetic and equilibrium on used different synthesized adsorbents. The adsorption tests were performed in various conditions, in addition to assess the effects of pH, temperature and adsorbent dosage. Equilibrium empirical data have been fitted by Langmuir, Sips, Freundlich, Toth, Khan, Tempkin and Redlich-Peterson isotherms. Correlation coefficients demonstrated that equilibrium data were better matched with the Redlich-Peterson (R-P) isotherm. On the other hand, experiments showed that the amount of adsorbate per unit mass of adsorbent is decreased by increasing of the pH, and the maximum value of qe is obtained in acidic pH. In addition, the amount of adsorbate per unit mass of adsorbent is reduced by rising temperature and the equilibrium adsorption is dropped by increasing the amount of silica adsorbent. Kinetic data have been fitted with Elovich, pseudo-first-order and pseudo-second-order models; according to the obtained correlation coefficients. It can be stated that the pseudo-first-order model is more suited to the kinetic data related to pesticide adsorption on silica adsorbent. Kinetics of imidacloprid adsorption has been investigated at the concentrations of 7.2 mg/L and 10 mg/L. The results demonstrated that the equilibrium rate slope become much steeper in the initial times by increasing concentrations of imidacloprid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.molliq.2018.06.041

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 87

Metadata

Authors
Kalhor, M. M., Rafati, A. A., Rafati, L., & Rafati, A. A.
Venue
Journal of Molecular Liquids
Publisher
Elsevier BV
Published
2018-09
Volume
266
Pages
453-459
ISSN
0167-7322 (ISSN-L)
OpenAlex
W2808268244
Cited by
87
References
2
FWCI
3.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Synthesis, characterization and adsorption studies of amino functionalized silica nano hollow sphere as an efficient adsorbent for removal of imidacloprid pesticide. https://app.cochat.ai/papers/10.1016/j.molliq.2018.06.041
The paper
Kalhor, M. M., Rafati, A. A., Rafati, L., & Rafati, A. A. (2018). Synthesis, characterization and adsorption studies of amino functionalized silica nano hollow sphere as an efficient adsorbent for removal of imidacloprid pesticide. Journal of Molecular Liquids. https://doi.org/10.1016/j.molliq.2018.06.041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.