Accuracy of image registration between MRI and light microscopy in the ex vivo brain
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A multi-step procedure was developed to register magnetic resonance imaging (MRI) and histological data from the same sample in the light microscopy image space, with the ultimate goal of allowing quantitative comparisons of the two datasets. The fixed brain of an owl monkey was used to develop and test the procedure. In addition to the MRI and histological data, photographic images of the brain tissue block acquired during sectioning were assembled into a blockface volume to provide an intermediate step for the overall registration process. The MR volume was first registered to the blockface volume using a combination of linear and nonlinear registration, and two dimensional (2D) blockface sections were registered to corresponding myelin stained sections using a combination of linear and nonlinear registration. Before this 2D registration, two major types of tissue distortions were corrected: tissue tearing and independent movement of different parts of the brain, both introduced during histological processing of the sections. The correction procedure utilized a 2D method to close tissue tears and a multiple iterative closest point (ICP) algorithm to reposition separate pieces of tissue in the image. The accuracy of the overall MR to micrograph registration procedure was assessed by measuring the distance between registered landmarks chosen in the MR image space and the corresponding landmarks chosen in the micrograph space. The average error distance of the MR data registered to micrograph data was 0.324 ± 0.277 mm, only 8% larger than the width of the MRI voxel (0.3 mm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 4×
“T2-w → Blockface—Linear registration was performed using a mutual information (MI) based method similar to that of Maes [19].”
BackgroundMethodInfluentialIntegrating spatially resolved three-dimensional MALDI IMS with in vivo magnetic resonance imaging
Sinha, T. K., Khatib-Shahidi, S., Yankeelov, T. E., Mapara, K., Ehtesham, M., Cornett, D. S., Dawant, B. M., Caprioli, R. M., & Gore, J. C. (2008) · Nature Methods · doi:10.1038/nmeth1147 · Cited by 168 · cited 1×
“Other studies have used this method successfully and also reported improved registration results due to decreased tissue distortions [25,26].”
Result
Cited by
Limits to anatomical accuracy of diffusion tractography using modern approaches
Schilling, K. G., Nath, V., Hansen, C., Parvathaneni, P., Blaber, J., Gao, Y., Neher, P., Aydogan, D. B., Shi, Y., Ocampo-Pineda, M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.10.029 · Cited by 260
Self-citationA survey of methods for 3D histology reconstruction
Pichat, J., Iglesias, J. E., Yousry, T., Ourselin, S., & Modat, M. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.02.004 · Cited by 207
“Choe et al. (2011) also described a similar strategy apart from the last step of the non-rigid registration between blockface and ex vivo T2w MR volumes, for which they made use of ABA.”
MethodInfluentialHistological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
Self-citationHistological validation of high-resolution DTI in human post mortem tissue
Seehaus, A., Roebroeck, A., Bastiani, M., Fonseca, L., Bratzke, H., Lori, N., Vilanova, A., Goebel, R., & Galuske, R. (2015) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2015.00098 · Cited by 149
Histological Validation of DW-MRI Tractography in Human Postmortem Tissue
Seehaus, A. K., Roebroeck, A., Chiry, O., Kim, D.-S., Ronen, I., Bratzke, H., Goebel, R., & Galuske, R. A. W. (2013) · Cerebral Cortex · doi:10.1093/cercor/bhs036 · Cited by 109
“Nevertheless, recent work shows that manual intervention is often still required with automated procedures (Choe et al. 2011).”
Background
Metadata
- Authors
- Choe, A. S., Gao, Y., Li, X., Compton, K. B., Stepniewska, I., & Anderson, A. W.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 2011-06
- Volume
- 29
- Issue
- 5
- Pages
- 683-692
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2137915146
- Cited by
- 78
- References
- 2
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of image registration between MRI and light microscopy in the ex vivo brain. https://app.cochat.ai/papers/10.1016/j.mri.2011.02.022
- The paper
- Choe, A. S., Gao, Y., Li, X., Compton, K. B., Stepniewska, I., & Anderson, A. W. (2011). Accuracy of image registration between MRI and light microscopy in the ex vivo brain. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2011.02.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.