CoChat

An approach for computer-aided detection of brain metastases in post-Gd T1-W MRI

Open access
Farjam, Reza, Parmar, Hemant A., Noll, Douglas C., Tsien, Christina I., Cao, Yue · 2012 · Magnetic Resonance Imaging
Cited by 45

The DOI matches its Crossref record.

Abstract

Purpose To develop an approach for computer-aided detection (CAD) of small brain metastases in post-Gd T1-weighted magnetic resonance imaging (MRI). Method A set of unevenly spaced 3D spherical shell templates was optimized to localize brain metastatic lesions by cross-correlation analysis with MRI. Theoretical and simulation analyses of effects of lesion size and shape heterogeneity were performed to optimize the number and size of the templates and the cross-correlation thresholds. Also, effects of image factors of noise and intensity variation on the performance of the CAD system were investigated. A nodule enhancement strategy to improve sensitivity of the system and a set of criteria based upon the size, shape and brightness of lesions were used to reduce false positives. An optimal set of parameters from the FROC curves was selected from a training dataset, and then the system was evaluated on a testing dataset including 186 lesions from 2753 MRI slices. Reading results from two radiologists are also included. Results Overall, a 93.5% sensitivity with 0.024 of intra-cranial false positive rate (IC-FPR) was achieved in the testing dataset. Our investigation indicated that nodule enhancement was very effective in improving both sensitivity and specificity. The size and shape criteria reduced the IC-FPR from 0.075 to 0.021, and the brightness criterion decreases the extra-cranial FPR from 0.477 to 0.083 in the training dataset. Readings from the two radiologists had sensitivities of 60% and 67% in the training dataset and 70% and 80% in the testing dataset for the metastatic lesions <5 mm in diameter. Conclusion Our proposed CAD system has high sensitivity and fairly low FPR for detection of the small brain metastatic lesions in MRI compared to the previous work and readings of neuroradiologists. The potential of this method for assisting clinical decision- making warrants further evaluation and improvements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.mri.2012.02.024

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Farjam, R., Parmar, H. A., Noll, D. C., Tsien, C. I., & Cao, Y.
Venue
Magnetic Resonance Imaging
Publisher
Elsevier BV
Published
2012-07
Volume
30
Issue
6
Pages
824-836
ISSN
0730-725X (ISSN-L)
OpenAlex
W1979835502
Cited by
45
References
0
FWCI
0.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.