Comparison of single voxel brain MRS AT 3T and 7T using 32-channel head coils
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose The purpose of this study was to compare magnetic resonance spectroscopy (MRS) of three different regions of the human brain between 3 and 7 Tesla, using the same subjects and closely matched methodology at both field strengths. Methods A semi-LASER (sLASER) pulse sequence with TE 32 ms was used to acquire metabolite spectrum along with the water reference at 3T and 7T using similar experimental parameters and hardware at both field strengths (n=4 per region and field). Spectra were analyzed in LCModel using a simulated basis set. Results Signal-to-noise ratio (SNR) at 7T was higher compared to 3T and linewidths (in ppm) at both field strengths were comparable in ppm scale. Of the 13 metabolites reported in the paper, most metabolites were measured with higher precision at 7T in all three regions. Conclusion The study confirms gains in SNR and measurement precision at 7T in all three representative brain regions using the sLASER pulse sequence coupled with a 32-channel phased-array head coil.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Return of the Frequency Sweep: Designing Adiabatic Pulses for Contemporary NMR
Garwood, M., & DelaBarre, L. (2001) · Journal of Magnetic Resonance · doi:10.1006/jmre.2001.2340 · Cited by 952
Cited by
Detcheverry, F., Senthil, S., Narayanan, S., & Badhwar, A. (2023) · NeuroImage: Clinical · doi:10.1016/j.nicl.2023.103503 · Cited by 64
“In general, these qualities allow for greater sensitivity and more reliable quantification of all metabolites, especially low-concentration metabolites such as GSH (Pradhan et al., 2015).”
BackgroundOnwordi, E. C., Whitehurst, T., Mansur, A., Statton, B., Berry, A., Quinlan, M., O’Regan, D. P., Rogdaki, M., Marques, T. R., Rabiner, E. A., et al. (2021) · Translational Psychiatry · doi:10.1038/s41398-021-01515-3 · Cited by 55
Bell, C. J. M., Mehta, M., Mirza, L., Young, A. H., & Beck, K. (2025) · Psychopharmacology · doi:10.1007/s00213-024-06735-1 · Cited by 28
“7 T is likely to give a more precise reading for metabolites than 3 T generally in MRS studies (Pradhan et al. 2015; Ladd et al. 2018), although there is no clear guidance on this specifically for GSH measurement.”
Dai, F., Wengler, K., He, X., Wang, J., Yang, J., Parsey, R. V., & DeLorenzo, C. (2025) · Translational Psychiatry · doi:10.1038/s41398-025-03292-9 · Cited by 12
Metadata
- Authors
- Pradhan, S., Bonekamp, S., Gillen, J. S., Rowland, L. M., Wijtenburg, S. A., Edden, R. A. E., & Barker, P. B.
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 2015-10
- Volume
- 33
- Issue
- 8
- Pages
- 1013-1018
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W1965026504
- Cited by
- 97
- References
- 1
- FWCI
- 5.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.