The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cu-nanoflower decorated gold nanoparticles-graphene oxide nanofiber as electrochemical biosensor for glucose detection
Abstract
A novel electrospinning approach is proposed for the fabrication of copper (Cu)-nanoflower decorated gold nanoparticles (AuNPs)-graphene oxide (GO) nanofiber (NF) as an electrochemical biosensor for the glucose detection. In this study, GO was mixed with poly(vinyl alcohol) (PVA) and used as a fiber precursor, which greatly improves the electrochemical properties. The above solution was uniformly coated onto the surfaces of gold chip to form GO NFs via electrospinning. AuNPs were coated onto the surface of GO NFs and then incorporated organic-inorganic hybrid nanoflower [Cu nanoflower-glucose oxidase (GOx) and horseradish peroxidase (HRP)]. The electrochemical experiments revealed that Cu-nanoflower@AuNPs-GO NFs exhibited outstanding electrochemical catalytic nature, and selectivity for the conversion of glucose to gluconic acid in the presence of GOx-HRP-Cu nanoflower. The Cu-nanoflower@AuNPs-GO NFs coated Au chip exhibited good linear range 0.001-0.1 mM, with a detection limit of 0.018 μM. The Cu-nanoflower@AuNPs-GO NFs modified Au chip exhibited higher catalytic properties, which are attributed to the coating of unique organic-inorganic nanostructured materials on the surfaces of Au chip. These results indicate that the nano-bio hybrid materials can be applied as a promising electrochemical biosensor to monitor glucose levels in biofluids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Cited by
Electrochemical non-enzymatic glucose sensors: recent progress and perspectives
Wei, M., Qiao, Y., Zhao, H., Liang, J., Li, T., Luo, Y., Lu, S., Shi, X., Lu, W., & Sun, X. (2020) · Chemical Communications · doi:10.1039/d0cc05650b · Cited by 467
Ramesh, M., Janani, R., Deepa, C., & Rajeshkumar, L. (2022) · Biosensors · doi:10.3390/bios13010040 · Cited by 443
Recent Advances in Enzymatic and Non-Enzymatic Electrochemical Glucose Sensing
Hassan, M. H., Vyas, C., Grieve, B., & Bartolo, P. (2021) · Sensors · doi:10.3390/s21144672 · Cited by 364
Metadata
- Authors
- Baek, S. H., Roh, J., Park, C. Y., Kim, M. W., Shi, R., Kailasa, S. K., & Park, T. J.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 107
- Pages
- 110273
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2981030046
- Cited by
- 207
- References
- 1
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cu-nanoflower decorated gold nanoparticles-graphene oxide nanofiber as electrochemical biosensor for glucose detection. https://app.cochat.ai/papers/10.1016/j.msec.2019.110273
- The paper
- Baek, S. H., Roh, J., Park, C. Y., Kim, M. W., Shi, R., Kailasa, S. K., & Park, T. J. (2020). Cu-nanoflower decorated gold nanoparticles-graphene oxide nanofiber as electrochemical biosensor for glucose detection. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2019.110273
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.