The DOI matches its Crossref record; 204 of the 204 references it cites were found in a registry or an index.
Biofilm formation to inhibition: Role of zinc oxide-based nanoparticles
Abstract
Zinc oxide nanoparticles have received much attention worldwide as they possess unique properties like varied morphology, large surface area to volume ratio, potent antibacterial activity, and biocompatibility. Biofilm contains homogenous or heterogeneous microorganisms that remain enclosed in a matrix of an extracellular polymeric substance on biotic or abiotic surfaces. Bacterial biofilm formed on medical devices such as central venous catheters, urinary catheters, prosthetic joints, cardiovascular implantable devices, dental implants, contact lenses, intrauterine contraceptive devices and breast implants cause persistent infections. Such biofilm-associated infections in medical implants cause serious problems for public health and affect the function of medical implants. So, there is an urgent need for the use of an antimicrobial agent that will inhibit biofilm, including such antibiotic-resistant bacterial strains as bacteria, to develop multiple drug-resistances resulting in failure of the antibiotic's action. The antimicrobial agent used should be ideal in terms of biocompatibility, antimicrobial activity, stability at different environmental conditions, with less sensitivity to the development of resistance towards micro-organisms, safe for in vivo and in vitro use, and remain non-hazardous to the environment, etc. The first objective of the review discusses the insights into the formation of biofilm on a medical device with the current strategies to inhibit. The second purpose is to review the recent progress in ZnO- based nanostructure including composites for antibacterial and anti-biofilm activities. This will offer a new opportunity for the application of Zinc oxide-based material in the prevention of biofilm on the medical devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 201–204 of 204
The Antibiofilm efficacy of nitric oxide on soft contact lenses
Kim, D. J., Park, J., Kim, M., & Park, C. Y. (2017) · BMC Ophthalmology · doi:10.1186/s12886-017-0604-2 · Cited by 14
Bedge, P. A., Bohara, R. A., Patil, P. M., Joshi, M. G., & Bohara, D. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813906-6.00003-2 · Cited by 10
Self-citationUsmani, S. Z., Choquette, L. E., Bona, R., Feinn, R., Shahid, Z., & Lalla, R. V. (2018) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2017.12.022 · Cited by 5
Chauhan, P., Dey, P., Mukherjee, S., Manna, U., Das, G. C., & Ramesh, A. (2018) · ChemistrySelect · doi:10.1002/slct.201702842 · Cited by 3
Cited by
Wojnarowicz, J., Chudoba, T., & Lojkowski, W. (2020) · Nanomaterials · doi:10.3390/nano10061086 · Cited by 361
Metadata
- Authors
- Mahamuni-Badiger, P. P., Patil, P. M., Badiger, M. V., Patel, P. R., Thorat- Gadgil, B. S., Pandit, A., & Bohara, R. A.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 108
- Pages
- 110319
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2981628794
- Cited by
- 264
- References
- 204
- FWCI
- 6.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.