Dual pH-responsive-charge-reversal micelle platform for enhanced anticancer therapy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel nanodrug delivery system (NDDS) based on block copolymers of Poly(DEA)-block-Poly(PgMA) (PDPP) was developed to enhance in vitro cellular uptake and anticancer efficacy. pH-responsive doxorubicin (DOX) based small molecule prodrug (DOX-hyd-N3) and mPEG-N3 were co-conjugated onto PDPP via copper-catalyzed "Click chemistry" to give a dual pH-responsive polymeric prodrug (mPEG-g-PDPP-g-hyd-DOX), which could be self-assembled into core-shell polymeric micelles (M(DOX)) with particles size of 81 ± 1 nm in aqueous phase. Additionally, the pH-responsive charge-reversal, stability and drug release behaviour at different pHs were then evaluated. Moreover, the surface charge of M(DOX) could quickly convert from negative (-6.64 ± 3.37 mV) to positive (5.35 ± 1.33 mV) thanks to the protonation of Poly(DEA) moieties as the pH value decreased from 7.4 during blood circulation to 6.5 in extracellular of tumour tissues. Meanwhile, according to the cytotoxicity determined by CCK-8 assay, cellular uptake, flow-cytometric and apoptosis profiles of two human cancer cell lines (HeLa and SW480), we could draw the conclusion that the cellular uptake and anticancer efficacy were significantly enhanced when cells were incubated with micelles at pH 6.5 due to the charge-reversal of micelles from negative to positive. With the protonation of Poly(DEA) moieties in acidic extracellular microenvironment and the pH-responsive DOX release with hydrazone linkage in endo/lysosome pH, this dual pH-responsive-charge-reversal micelle platform might become an encouraging strategy for more effective cancer treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure and properties of pharmacologically active polymers
Ringsdorf, H. (1975) · Journal of Polymer Science: Polymer Symposia · doi:10.1002/polc.5070510111 · Cited by 1,094
Nanotechnology-based antimicrobials and delivery systems for biofilm-infection control
Liu, Y., Shi, L., Su, L., van der Mei, H. C., Jutte, P. C., Ren, Y., & Busscher, H. J. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00807d · Cited by 737
Cited by
Hydrogels and Nanogels: Pioneering the Future of Advanced Drug Delivery Systems
Delgado-Pujol, E. J., Martínez, G., Casado-Jurado, D., Vázquez, J., León-Barberena, J., Rodríguez-Lucena, D., Torres, Y., Alcudia, A., & Begines, B. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17020215 · Cited by 216
Liang, X., Wang, Y., Shi, H., Dong, M., Han, H., & Li, Q. (2021) · International Journal of Nanomedicine · doi:10.2147/ijn.s304526 · Cited by 41
Das, M., Joshi, A., Devkar, R., Seshadri, S., & Thakore, S. (2022) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.1c00614 · Cited by 27
Metadata
- Authors
- Liao, J., Peng, H., Liu, C., Li, D., Yin, Y., Lu, B., Zheng, H., & Wang, Q.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 118
- Pages
- 111527
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W3088847182
- Cited by
- 68
- References
- 2
- FWCI
- 2.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual pH-responsive-charge-reversal micelle platform for enhanced anticancer therapy. https://app.cochat.ai/papers/10.1016/j.msec.2020.111527
- The paper
- Liao, J., Peng, H., Liu, C., Li, D., Yin, Y., Lu, B., Zheng, H., & Wang, Q. (2021). Dual pH-responsive-charge-reversal micelle platform for enhanced anticancer therapy. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2020.111527
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.