Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Stretchable array of high-performance micro-supercapacitors charged with solar cells for wireless powering of an integrated strain sensor

Yun, Junyeong, Song, Changhoon, Lee, Hanchan, Park, Heun, Jeong, Yu Ra, Kim, Jung Wook, Jin, Sang Woo, Oh, Seung Yun, Sun, Lianfang, Zi, Goangseup, Ha, Jeong Sook·2018·Nano Energy

Abstract

Abstract The aim of this paper is to report on the fabrication of a stretchable array of high-performance solid-state micro-supercapacitors (MSCs), which can be charged with integrated, commercial Si-based solar cells (SCs). This would facilitate the powering of an integrated strain sensor. The planar MSCs comprised electrodes of potentiostatically deposited polypyrrole, on spray-coated multi-walled carbon nanotube film, and a gel-type electrolyte of LiCl/polyvinyl alcohol with a redox additive of 1-methyl-3-propylimidazolium iodide. The fabricated MSC achieved an areal capacitance of 5.17 mF cm−2. After 5000 charge/discharge cycles, the MSC retained 80% of their initial capacitance. A strain sensor was fabricated utilizing a composite film of fragmentized graphene foam and polydimethylsiloxane. Such fabricated twelve parallel connected MSCs, a strain sensor, and SCs were integrated on a single deformable polymer substrate with embedded stiff platforms of negative epoxy series resist (SU-8) via long serpentine interconnections of polyimide encapsulated Ti/Pt metal film for mechanical stability under stretching. After 1000 repetitive biaxial stretching/releasing cycles by 30%, no noticeable change was observed in the charge/discharge behavior of the MSC array. Furthermore, both the photo-charge/discharge characteristics and electrochemical performance remained stable. When the whole integrated system was attached to the wrist, the integrated strain sensor could detect both externally applied strain and the arterial pulse using the energy stored in the MSCs from the SCs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2018.05.017

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 189

Metadata

Authors
Yun, J., Song, C., Lee, H., Park, H., Jeong, Y. R., Kim, J. W., Jin, S. W., Oh, S. Y., Sun, L., Zi, G., & Ha, J. S.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2018-07
Volume
49
Pages
644-654
ISSN
2211-2855 (ISSN-L)
OpenAlex
W2800513659
Cited by
189
References
1
FWCI
6.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stretchable array of high-performance micro-supercapacitors charged with solar cells for wireless powering of an integrated strain sensor. https://app.cochat.ai/papers/10.1016/j.nanoen.2018.05.017
The paper
Yun, J., Song, C., Lee, H., Park, H., Jeong, Y. R., Kim, J. W., Jin, S. W., Oh, S. Y., Sun, L., Zi, G., & Ha, J. S. (2018). Stretchable array of high-performance micro-supercapacitors charged with solar cells for wireless powering of an integrated strain sensor. Nano Energy. https://doi.org/10.1016/j.nanoen.2018.05.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.