Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 160

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

A calibration-free self-powered sensor for vital sign monitoring and finger tap communication based on wearable triboelectric nanogenerator

Qiu, Hui-Jing, Song, Wei-Zhi, Wang, Xiao-Xiong, Zhang, Jun, Fan, Zhiyong, Yu, Miao, Ramakrishna, Seeram, Long, Yun-Ze·2019·Nano Energy

Abstract

Abstract Triboelectric nanogenerators (TENGs) have attracted much attention due to the high output, low cost, and environmentally friendly nature. However, wearable devices still have certain hardness due to the choice of metal electrode, which has no gas permeability, and affects the wearing comfort. In addition, the electrode does not adhere firmly to the friction material, which also affects the electric performance. We report a TENG base on ordinary fabrics with polymerizes polyaniline (PANI) as electrodes, and uses polycaprolactone (PCL) to make the fabric and friction material fit well. The TENG have excellent softness and certain gas permeability, improving the comfort of the wearable smart health monitoring. The output electrical of TENG can arrive 200 µA and 1000 V under a frequency of 2.5 Hz. It can drive about 1000 LEDs and continuously supply power to electronic production. This truly wearable generator can provide a good information interface for critically ill patients. On the one hand, it can monitor the patient's breathing state in real time and give an alarm when the breathing stops. On the other hand, patients with language communication difficulty can also tap the finger to send messages by using Morse code. More importantly, we have experimentally proved that this self-powered sensor can still work normally with additional contact resistance, which will guarantee the long-term reliable operation of this device in a flexible environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2019.01.069

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 160

Metadata

Authors
Qiu, H.-J., Song, W.-Z., Wang, X.-X., Zhang, J., Fan, Z., Yu, M., Ramakrishna, S., & Long, Y.-Z.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2019-04
Volume
58
Pages
536-542
ISSN
2211-2855 (ISSN-L)
OpenAlex
W2912328934
Cited by
160
References
4
FWCI
7.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A calibration-free self-powered sensor for vital sign monitoring and finger tap communication based on wearable triboelectric nanogenerator. https://app.cochat.ai/papers/10.1016/j.nanoen.2019.01.069
The paper
Qiu, H.-J., Song, W.-Z., Wang, X.-X., Zhang, J., Fan, Z., Yu, M., Ramakrishna, S., & Long, Y.-Z. (2019). A calibration-free self-powered sensor for vital sign monitoring and finger tap communication based on wearable triboelectric nanogenerator. Nano Energy. https://doi.org/10.1016/j.nanoen.2019.01.069

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.