Accelerated wound healing with an ionic patch assisted by a triboelectric nanogenerator
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Abstract Electrical stimulation therapy has recently been suggested as a therapeutic modality to accelerate wound healing. Despite advancements in the development of flexible electronic devices for rapid wound recovery, current systems, which are fabricated from various metals, have mechanical discontinuities that have not been fully resolved, making them unsuitable for wearable applications. Here, we introduce a wearable ionic triboelectric nanogenerator (iTENG) patch, composed of a fully stretchable gel-based platform comprising a TENG, wire, and patch that harvests biophysical energy and delivers electric potential to an impaired tissue. Ionically conductive and stretchable organogel fibers in an elastomeric microtubular structure act as both a stretchable wire and a wearable generator as they are woven like fabric. The elastomeric film-encapsulated ionic patch is multifunctional, serving as both a wound dressing and an electrode. It provides a uniform and symmetrical electric field directly to a wound bed. The electric field generated by an iTENG was shown to accelerate in vitro cell migration, proliferation, and secretion of angiogenic growth factors in studies on both normal human dermal fibroblasts and dermal fibroblasts from diabetes mellitus patients. Rapid wound closure by electrical stimulation using iTENG patches in in vivo animal models has also been verified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stretchable, Transparent, Ionic Conductors
Keplinger, C., Sun, J.-Y., Foo, C. C., Rothemund, P., Whitesides, G. M., & Suo, Z. (2013) · Science · doi:10.1126/science.1240228 · Cited by 1,754
Self-citationEffective Wound Healing Enabled by Discrete Alternative Electric Fields from Wearable Nanogenerators
Long, Y., Wei, H., Li, J., Yao, G., Yu, B., Ni, D., Gibson, A. L., Lan, X., Jiang, Y., Cai, W., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b07038 · Cited by 397
Levinson, H. (2013) · Advances in Wound Care · doi:10.1089/wound.2012.0389 · Cited by 30
Cited by
Conductive Biomaterials as Bioactive Wound Dressing for Wound Healing and Skin Tissue Engineering
Yu, R., Zhang, H., & Guo, B. (2022) · Nano-Micro Letters · doi:10.1007/s40820-021-00751-y · Cited by 880
Smart textiles for personalized healthcare
Libanori, A., Chen, G., Zhao, X., Zhou, Y., & Chen, J. (2022) · Nature Electronics · doi:10.1038/s41928-022-00723-z · Cited by 739
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Choi, D., Lee, Y., Lin, Z.-H., Cho, S., Kim, M., Ao, C. K., Soh, S., Sohn, C., Jeong, C. K., Lee, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12458 · Cited by 656
Self-citationZheng, K., Tong, Y., Zhang, S., He, R., Xiao, L., Iqbal, Z., Zhang, Y., Gao, J., Zhang, L., Jiang, L., et al. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202102599 · Cited by 290
Metadata
- Authors
- Jeong, S.-H., Lee, Y., Lee, M.-G., Song, W. J., Park, J.-U., & Sun, J.-Y.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 79
- Pages
- 105463
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3091841519
- Cited by
- 200
- References
- 3
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.