Thermoelectric coolers as thermal management systems for medical applications: Design, optimization, and advancement
The DOI matches its Crossref record; 108 of the 108 references it cites were found in a registry or an index.
Abstract
Abstract Compared with traditional cooling techniques, thermoelectric coolers have drawn massive attention for small-scale cooling applications, particularly in medical practices. Thermoelectric coolers offer the benefits of having more environmentally friendly systems, a silent and robust structure, and reliable temperature control. Considering the recent rapid developments in this field, this article comprehensively reviews thermoelectric refrigerators for thermal management systems in medical practices, such as cooling carriers and wearable medical devices. Thermal optimization of thermoelectric coolers is assessed according to the available mechanisms, namely 1) using efficient thermoelectric materials, 2) designing efficient heat sink and absorption - especially applying phase change materials, and heat pipes, and 3) production methods for flexible thermoelectric devices, such as printing techniques. In the end, we point out that novel thermoelectric cooler technologies have gradually replaced traditional refrigerators due to their advantages of small size, flexibility, and pollution-free characteristics for medical applications, alongside wearable technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complex thermoelectric materials
Snyder, G. J., & Toberer, E. S. (2008) · Nature Materials · doi:10.1038/nmat2090 · Cited by 11,455
Enhancement of Thermoelectric Efficiency in PbTe by Distortion of the Electronic Density of States
Heremans, J. P., Jovovic, V., Toberer, E. S., Saramat, A., Kurosaki, K., Charoenphakdee, A., Yamanaka, S., & Snyder, G. J. (2008) · Science · doi:10.1126/science.1159725 · Cited by 4,161
Materials used as PCM in thermal energy storage in buildings: A review
Cabeza, L. F., Castell, A., Barreneche, C., de Gracia, A., & Fernández, A. I. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2010.11.018 · Cited by 1,889
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Goldsmid, H. J. (1964) · Springer eBooks · doi:10.1007/978-1-4899-5723-8 · Cited by 1,058
Zhang, Q., Sun, Y., Xu, W., & Zhu, D. (2014) · Advanced Materials · doi:10.1002/adma.201305371 · Cited by 999
High Performance Thermoelectric Materials: Progress and Their Applications
Yang, L., Chen, Z., Dargusch, M. S., & Zou, J. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201701797 · Cited by 958
Self-citationWen, Z., Yeh, M.-H., Guo, H., Wang, J., Zi, Y., Xu, W., Deng, J., Zhu, L., Wang, X., Hu, C., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600097 · Cited by 854
Thermoelectric cooling materials
Mao, J., Chen, G., & Ren, Z. (2021) · Nature Materials · doi:10.1038/s41563-020-00852-w · Cited by 797
Relationship between thermoelectric figure of merit and energy conversion efficiency
Kim, H. S., Liu, W., Chen, G., Chu, C. W., & Ren, Z. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1510231112 · Cited by 654
Cited by
Thermoelectric coolers for on-chip thermal management: Materials, design, and optimization
Chen, W.-Y., Shi, X.-L., Zou, J., & Chen, Z.-G. (2022) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2022.100700 · Cited by 312
Self-citationToward Efficient Thermoelectric Materials and Devices: Advances, Challenges, and Opportunities
Shi, X.-L., Li, N.-H., Li, M., & Chen, Z.-G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00060 · Cited by 260
Self-citationThermoelectrics for medical applications: Progress, challenges, and perspectives
Hu, B., Shi, X.-L., Zou, J., & Chen, Z.-G. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.135268 · Cited by 220
Self-citationThermoelectric Coolers: Progress, Challenges, and Opportunities
Chen, W., Shi, X., Zou, J., & Chen, Z. (2022) · Small Methods · doi:10.1002/smtd.202101235 · Cited by 219
Self-citationPiezoelectricity, Pyroelectricity, and Ferroelectricity in Biomaterials and Biomedical Applications
Yuan, X., Shi, J., Kang, Y., Dong, J., Pei, Z., & Ji, X. (2024) · Advanced Materials · doi:10.1002/adma.202308726 · Cited by 198
Advancing flexible thermoelectrics for integrated electronics
Shi, X.-L., Wang, L., Lyu, W., Cao, T., Chen, W., Hu, B., & Chen, Z.-G. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00361f · Cited by 186
Self-citation
Metadata
- Authors
- Zaferani, S. H., Sams, M. W., Ghomashchi, R., & Chen, Z.-G.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2021-12
- Volume
- 90
- Pages
- 106572
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W3203760562
- Cited by
- 162
- References
- 108
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.