The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model
Open accessAbstract
The major goal of the evaluation in presurgical epilepsy diagnosis for medically intractable patients is the precise reconstruction of the epileptogenic foci, preferably with non-invasive methods. This paper evaluates whether surface electroencephalography (EEG) source analysis based on a 1mm anisotropic finite element (FE) head model can provide additional guidance for presurgical epilepsy diagnosis and whether it is practically feasible in daily routine. A 1mm hexahedra FE volume conductor model of the patient’s head with special focus on accurately modeling the compartments skull, cerebrospinal fluid (CSF) and the anisotropic conducting brain tissues was constructed using non-linearly co-registered T1-, T2- and diffusion-tensor- magnetic resonance imaging data. The electrodes of intra-cranial EEG (iEEG) measurements were extracted from a co-registered computed tomography image. Goal function scan (GFS), minimum norm least squares (MNLS), standardized low resolution electromagnetic tomography (sLORETA) and spatio-temporal current dipole modeling inverse methods were then applied to the peak of the averaged ictal discharges EEG data. MNLS and sLORETA pointed to a single center of activity. Moving and rotating single dipole fits resulted in an explained variance of more than 97%. The non-invasive EEG source analysis methods localized at the border of the lesion and at the border of the iEEG electrodes which mainly received ictal discharges. Source orientation was towards the epileptogenic tissue. For the reconstructed superficial source, brain conductivity anisotropy and the lesion conductivity had only a minor influence, whereas a correct modeling of the highly conducting CSF compartment and the anisotropic skull was found to be important. The proposed FE forward modeling approach strongly simplifies meshing and reduces run-time (37 Milliseconds for one forward computation in the model with 3.1 Million unknowns), corroborating the practical feasibility of the approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
The electrical conductivity of human cerebrospinal fluid at body temperature
Baumann, S. B., Wozny, D. R., Kelly, S. K., & Meno, F. M. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.554770 · Cited by 494
Cited by
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Windhoff, M., Opitz, A., & Thielscher, A. (2013) · Human Brain Mapping · doi:10.1002/hbm.21479 · Cited by 441
How the brain tissue shapes the electric field induced by transcranial magnetic stimulation
Opitz, A., Windhoff, M., Heidemann, R. M., Turner, R., & Thielscher, A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.069 · Cited by 360
A guideline for head volume conductor modeling in EEG and MEG
Vorwerk, J., Cho, J.-H., Rampp, S., Hamer, H., Knösche, T. R., & Wolters, C. H. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.06.040 · Cited by 302
Self-citationVariation in Reported Human Head Tissue Electrical Conductivity Values
McCann, H., Pisano, G., & Beltrachini, L. (2019) · Brain Topography · doi:10.1007/s10548-019-00710-2 · Cited by 293
Metadata
- Authors
- RULLMANN, M., ANWANDER, A., DANNHAUER, M., WARFIELD, S., DUFFY, F., & WOLTERS, C.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2009-01-15
- Volume
- 44
- Issue
- 2
- Pages
- 399-410
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2097540730
- Cited by
- 161
- References
- 2
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model. https://app.cochat.ai/papers/10.1016/j.neuroimage.2008.09.009
- The paper
- RULLMANN, M., ANWANDER, A., DANNHAUER, M., WARFIELD, S., DUFFY, F., & WOLTERS, C. (2009). EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model. NeuroImage. https://doi.org/10.1016/j.neuroimage.2008.09.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.