Cited by 79Advanced Neuroimaging Techniques and ApplicationsAdvanced MRI Techniques and ApplicationsFunctional Brain Connectivity Studies

How does angular resolution affect diffusion imaging measures?

Open access
Zhan, Liang, Leow, Alex D., Jahanshad, Neda, Chiang, Ming-Chang, Barysheva, Marina, Lee, Agatha D., Toga, Arthur W., McMahon, Katie L. +3 more·2010·NeuroImage

Abstract

A key question in diffusion imaging is how many diffusion-weighted images suffice to provide adequate signal-to-noise ratio (SNR) for studies of fiber integrity. Motion, physiological effects, and scan duration all affect the achievable SNR in real brain images, making theoretical studies and simulations only partially useful. We therefore scanned 50 healthy adults with 105-gradient high-angular resolution diffusion imaging (HARDI) at 4T. From gradient image subsets of varying size (6<or=N<or=94) that optimized a spherical angular distribution energy, we created SNR plots (versus gradient numbers) for seven common diffusion anisotropy indices: fractional and relative anisotropy (FA, RA), mean diffusivity (MD), volume ratio (VR), geodesic anisotropy (GA), its hyperbolic tangent (tGA), and generalized fractional anisotropy (GFA). SNR, defined in a region of interest in the corpus callosum, was near-maximal with 58, 66, and 62 gradients for MD, FA, and RA, respectively, and with about 55 gradients for GA and tGA. For VR and GFA, SNR increased rapidly with more gradients. SNR was optimized when the ratio of diffusion-sensitized to non-sensitized images was 9.13 for GA and tGA, 10.57 for FA, 9.17 for RA, and 26 for MD and VR. In orientation density functions modeling the HARDI signal as a continuous mixture of tensors, the diffusion profile reconstruction accuracy rose rapidly with additional gradients. These plots may help in making trade-off decisions when designing diffusion imaging protocols.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.neuroimage.2009.09.057

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Differences in dMRI acquisition parameters, including vendor, voxel size, and angular resolution, are known to affect derived dMRI measures.

    “differences in dMRI acquisition parameters, including vendor, voxel size, and angular resolution, are known to affect derived dMRI measures (Alexander et al., 2001; Cercignani et al., 2003; Zhan et al., 2010; Zhu et al., 2011).”

    From Diffusion MRI Indices and Their Relation to Cognitive Impairment in Brain Aging: The Updated Multi-protocol Approach in ADNI3 (2019) · cites this paper as Zhan et al., 2010

    The Conclusions report that the number of diffusion gradients affects the signal-to-noise ratio of derived measures, supporting the angular-resolution part of the claim. They also say achievable SNR depends on the scanner and spatial resolution, but do not establish that vendor or voxel-size differences affect derived dMRI measures. No page numbers are available in our copy. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 53 · Cited by 79

Research works printed but not linked: 49

  1. Alexander DC Maximum entropy spherical deconvolution for diffusion MRI 2005 19 76 87 Proceedings of the 19th International Conference on Information Processing in Medical Imaging (IPMI) 17354686
  2. Alexander DC Barker GJ Optimal imaging parameters for fiber- orientation estimation in diffusion MRI Neuroimage 2005 27 2 357 67 15921931
  3. Anderson AW Measurement of fiber orientation distributions using high angular resolution diffusion imaging Magnetic Resonance in Medicine 2005 54 1194 1206 16161109
  4. Basser PJ Pierpaoli C Microstructural and physiological features of tissues elucidated by quantitative diffusion tensor MRI Journal of Magnetic Resonance, Series B 1996 111 3 209 219 8661285
  5. Batchelor P Optimization of direction schemes for diffusion tensor imaging 2002 Proceedings of the workshop on diffusion MRI: biophysical issues (What can we measure?) St. Malo, France
  6. Chiang MC Barysheva M Lee AD Madsen SK Klunder AD Toga AW McMahon KL de Zubicaray GI Meredith M Wright MJ Srivastava A Balov N Thompson PM Mapping Genetic Influences on Brain Fiber Architecture with High Angular Resolution Diffusion Imaging (HARDI) 2008 871 874 5th International Symposium on Biomedical Imaging: From Nano to Macro (ISBI2008) PMC3073165 18979850
  7. Chiang MC Barysheva M Lee AD Madsen SK Klunder AD Toga AW McMahon KL de Zubicaray GI Wright MJ Srivastava A Balov N Thompson PM Genetics of Brain Fiber Architecture and Intelligence Journal of Neuroscience 2009 29 7 2212 2224 19228974 PMC2773128
  8. Cho KH Yeh CH Tournier JD Chao YP Chen JH Li CP Evaluation of the accuracy and angular resolution of q-ball imaging NeuroImage 2008 42 1 262 271 18502152
  9. de Zubicaray GI Chiang M-C McMahon KL Shattuck DW Toga AW Martin NG Wright MJ Thompson PM van Horn JD Meeting the challenges of neuroimaging genetics Brain Imaging Behav 2008 Special Issue published online, August 2008 PMC2794202 20016769
  10. Descoteaux M Angelino E Fitzgibbons S Deriche R Regularized, Fast and Robust Analytical Q-Ball Imaging Magnetic Resonance in Medicine 2007 58 3 497 510 17763358
  11. Farrell JAD Landman BA Jones CK Smith SA Prince JL van Zijl PCM Mori S Effects of Signal-to-Noise Ratio on the Accuracy and Reproducibility of Diffusion Tensor Imaging-Derived Fractional Anisotropy, Mean Diffusivity, and Principal Eigenvector Measurements at 1.5T Journal of Magnetic Resonance Imaging 2007 26 756 767 17729339 PMC2862967
  12. Goh A Lenglet C Thompson PM Vidal R A Nonparametric Riemannian Framework for Processing High Angular Resolution Diffusion Images (HARDI), Computer Vision and Pattern Recognition (CVPR) 2009a PMC3085642 21292013
  13. Goh A Lenglet C Thompson PM Vidal R Estimating Orientation Distributions with Probability Density Constraints and Spatial Regularity Medical Image Computing and Computer Assisted Intervention (MICCAI2009) Sept. 2009b London, UK 2009 20426071
  14. Hasan KM Analysis, Optimization and Evaluation of Water Spin Self-Diffusion Tensor Imaging Encoding and Acquisition Schemes PhD. Dissertation 2000 216 Department of Physics: Salt Lake City, University of Utah
  15. Hasan KM Parker DL Alexander AL Comparison of gradient encoding schemes for diffusion-tensor MRI Journal of Magnetic Resonance Imaging 2001 13 769 780 11329200
  16. Hess CP Mukherjee P Han ET Xu D Vigneron DB Q-ball reconstruction of multimodal fiber orientations using the spherical harmonic basis Magnetic Resonance in Medicine 2006 56 104 117 16755539
  17. Jbabdi S Woolrich MW Andersson JLR Behrens TEJ A Bayesian framework for global tractography NeuroImage 2007 37 116 129 17543543
  18. Jian B Vemuri BC A unified computational framework for deconvolution to reconstruct multiple fibers from diffusion weighted MRI IEEE Transactions on Medical Imaging 2007 26 11 1464 1471 18041262 PMC2572690
  19. Jones DK Horsfield MA Simmons A Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging Magnetic Resonance in Medicine 1999 42 3 515 525 10467296
  20. Jones DK The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study Magnetic Resonance in Medicine 2004 51 4 807 815 15065255
  21. Kaden E KnÖsche TR Anwander A Parametric spherical deconvolution: Inferring anatomical connectivity using diffusion MR imaging NeuroImage 2007 37 474 488 17596967
  22. King RB Applications of graph theory and topology in inorganic cluster and coordination chemistry 1993 47 69 CRC Press Boca Raton, Florida
  23. Kingsley PB Optimization of DTI acquisition parameters 2005 Proceedings of the 13th Annual Meeting of ISMRM Miami Beach FL, USA 2005 (Abstract 1294)
  24. Koay CG Chang LC Pierpaoli C Basser PJ Error propagation framework for diffusion tensor imaging via diffusion tensor representations IEEE transactions on medical imaging 2007 26 8 1017 1034 17695123
  25. Kuo LW Chen JH Wedeen VJ Tseng WYI Optimization of Diffusion Spectrum Imaging and Q-ball Imaging on Clinical MRI System NeuroImage 2008 41 1 7 18 18387822
  26. Landman BA Farrell JAD Jones CK Smith SA Prince JL Mori S Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T NeuroImage 2007 36 1123 1138 17532649 PMC12008999
  27. LeBihan D IVIM method measures diffusion and perfusion Diagn Imaging (San Franc) 1990a 12 6 133 136 10149369
  28. LeBihan D Magnetic resonance imaging of perfusion Magnetic Resonance in Medicine 1990b 14 2 283 292 2345508
  29. Lee AD Lepore N Barysheva M Chou YY Brun CA Madsen SK McMahon KL de Zubicaray GI Meredith M Wright MJ Toga AW Thompson PM Comparison of Fractional and Geodesic Anisotropy in Diffusion Tensor Images of 90 Monzygotic and Dizygotic Twins 2008 IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI2008) PMC6289524 30546820
  30. Lenglet C Campbell JSW Descoteaux M Haro G Savadjiev P Wassermann D Anwander A Deriche R Pike GB Sapiro G Siddiqi K Thompson PM Mathematical Methods for Diffusion MRI Processing NeuroImage - Special Issue on Mathematics in Brain Imaging 2008 [Epub ahead of print] PMC2678879 19063977
  31. Leow AD Zhu S Zhan L de Zubicaray GI Meredith M Wright M Toga AW Thompson PM The Tensor Distribution Function Magnetic Resonance in Medicine 2009 61 1 205 214 19097208 PMC2770429
  32. Lepore N Chou YY Lopez OL Aizenstein HJ Becker JT Toga AW Thompson PM Fast 3D Fluid Registration of Brain Magnetic Resonance Images SPIE 2008 2008 PMC6289542 30546193
  33. Özarslan E Shepherd T Vemuri BC Blackband S Mareci T Resolution of complex tissue microarchitecture using the diffusion orientation transform (DOT) NeuroImage 2006 31 3 1083 1106 16546404
  34. Papadakis NG Murrills CD Hall LD Huang CLH Carpenter TA Minimal gradient encoding for robust estimation of diffusion anisotropy Magnetic Resonance Imaging 2000 18 671 679 10930776
  35. Papadakis NG Xing D Huang CL Hall LD Carpenter TA A comparative study of acquisition schemes for diffusion tensor imaging using MRI J Magn Reson 1999 137 67 82 10053134
  36. Pennec X Fillard P Ayache N A Riemannian Framework for Tensor Computing International Journal of Computer Vision 2004 66 1 41 66
  37. Pichon E Westin C Tannenbaum A A Hamilton-Jacobi-Bellman approach to high angular resolution diffusion tractography 2005 180 197 Eighth International Conference on Medical Image Computing and Computer-Assisted Intervention (MICCAI05) PMC3644396 16685844
  38. Poonawalla AH Zhou XH Analytical Error Propagation in Diffusion Anisotropy Calculations Journal of Magnetic Resonance Imaging 2004 19 489 498 15065174
  39. Reese TG Heid O Weisskoff RM Wedeen VJ Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo Magn Reson Med 2003 49 177 182 12509835
  40. Shattuck DW Leahy RM BrainSuite: an automated cortical surface identification tool Med Image Anal 2002 6 2 129 42 12045000
  41. Stejskal EO Tanner JE Spin diffusion measurements: spin echoes in the presence of a time-dependent field gradient Journal of Chemical Physics 1965 42 288 292
  42. Tournier JD Calamante F Gadian D Connelly A Direct estimation of the fiber orientation density function from diffusion-weighted MRI data using spherical deconvolution NeuroImage 2004 23 1176 1185 15528117
  43. Wong STS Roos MS A strategy for sampling on a sphere applied to 3D selective RF pulse design Magn Reson Med 1994 32 778 784 7869901
  44. Xing D Papadakis NG Huang CL Lee VM Carpenter TA Hall LD Optimized diffusion-weighting for measurement of apparent diffusion coefficient (ADC) in human brain Magn Reson Imaging 1997 15 771 784 9309608
  45. Zhan L Leow AD Zhu S Hageman N Chiang MC Barysheva M Toga AW Thompson PM What does Fractional Anisotropy (FA) really measure? Medical Image Computing and Computer Assisted Intervention (MICCAI2009) Sept 2009a London, UK 2009, in press 20426067
  46. Zhan L Leow AD Zhu S Chiang MC Barysheva M Toga AW McMahon KL de Zubicaray GI Wright MJ Thompson PM Analyzing Multi-Fiber Reconstruction in High Angular Resolution Diffusion Imaging using the Tensor Distribution Function 2009b 6th IEEE International Symposium on Biomedical Imaging: From Nano to Macro (ISBI 2009) Boston, MA
  47. Zhan L Leow AD Barysheva M Feng A Toga AW Sapiro G Harel N Lim KO Lenglet C McMahon KL de Zubicaray GI Wright MJ Thompson PM Kilian Pohl Sarang Joshi Sandy Wells Investigating the uncertainty in multi-fiber estimation in High Angular Resolution Diffusion Imaging, Medical Image Computing and Computer Assisted Intervention (MICCAI2009) Sept 2009c 12 Workshop on Probabilistic Modeling in Medical Image Analysis (PMMIA) London, UK 2009
  48. Zhu T Liu X Gaugh MD Connelly PR Ni H Ekholm S Schifitto G Zhong J Evaluation of measurement uncertainties in human diffusion tensor imaging (DTI)-derived parameters and optimization of clinical DTI protocols with a wild bootstrap analysis Journal of Magnetic Resonance Imaging 2009 29 2 422 435 19161198
  49. Zhuang J Hrabe J Kangarlu A Xu D Bansal R Branch CA Peterson BS Correction of Eddy-Current Distortions in Diffusion Tensor Images Using the Known Directions and Strengths of Diffusion Gradients J Magn Reson Imaging November 2006 24 5 1188 1193 2006 17024663 PMC2364728

Authors
Zhan, L., Leow, A. D., Jahanshad, N., Chiang, M.-C., Barysheva, M., Lee, A. D., Toga, A. W., McMahon, K. L., de Zubicaray, G. I., Wright, M. J., & Thompson, P. M.
Affiliations
  • University of California, Los Angeles (US)
  • The University of Queensland (AU)
  • QIMR Berghofer Medical Research Institute (AU)
Corresponding author
Thompson, Paul M.
Venue
NeuroImage
Publisher
Elsevier BV
Published
2010-01
Volume
49
Issue
2
Pages
1357-1371
ISSN
1053-8119 (ISSN-L)
OpenAlex
W2094269283
Cited by
79
References
53
Citations by year
2026: 1 · 2025: 4 · 2024: 3 · 2023: 6 · 2022: 3 · 2021: 4 · 2020: 6 · 2019: 5 · 2018: 2 · 2017: 6 · 2016: 1 · 2015: 3 · 2014: 6 · 2013: 14 · 2012: 8
FWCI
3.78
Type
journal article
Language
en
Open access
Locations
  • NeuroImage (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • NIH (R01 HD050735, EB007813, EB008281, EB008432, HD050735, AG020098)
  • National Health and Medical Research Council, Australia (496682)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Functional Brain Connectivity Studies
Keywords
high angular resolution diffusion imaging, angular resolution, signal-to-noise ratio, diffusion-weighted imaging, fiber integrity, fractional anisotropy, generalized fractional anisotropy, mean diffusivity, volume ratio, corpus callosum, orientation density function
MeSH terms
Algorithms, Computer Simulation, Corpus Callosum, Diffusion, Female, Humans, Male, Models, Neurological, Anisotropy, Imaging, Three-Dimensional, Diffusion Magnetic Resonance Imaging, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›