The DOI matches its Crossref record.
A multi-centre evaluation of eleven clinically feasible brain PET/MRI attenuation correction techniques using a large cohort of patients
Open accessAbstract
Aim To accurately quantify the radioactivity concentration measured by PET , emission data need to be corrected for photon attenuation; however, the MRI signal cannot easily be converted into attenuation values, making attenuation correction (AC) in PET/MRI challenging. In order to further improve the current vendor-implemented MR-AC methods for absolute quantification, a number of prototype methods have been proposed in the literature. These can be categorized into three types: template/atlas-based, segmentation-based, and reconstruction-based. These proposed methods in general demonstrated improvements compared to vendor-implemented AC, and many studies report deviations in PET uptake after AC of only a few percent from a gold standard CT-AC. Using a unified quantitative evaluation with identical metrics, subject cohort, and common CT-based reference, the aims of this study were to evaluate a selection of novel methods proposed in the literature, and identify the ones suitable for clinical use. Methods In total, 11 AC methods were evaluated: two vendor-implemented (MR-AC DIXON and MR-AC UTE ), five based on template/atlas information (MR-AC SEGBONE (Koesters et al., 2016), MR-AC ONTARIO (Anazodo et al., 2014), MR-AC BOSTON (Izquierdo-Garcia et al., 2014), MR-AC UCL (Burgos et al., 2014), and MR-AC MAXPROB (Merida et al., 2015)), one based on simultaneous reconstruction of attenuation and emission (MR-AC MLAA (Benoit et al., 2015)), and three based on image-segmentation (MR-AC MUNICH (Cabello et al., 2015), MR-AC CAR-RiDR (Juttukonda et al., 2015), and MR-AC RESOLUTE (Ladefoged et al., 2015)). We selected 359 subjects who were scanned using one of the following radiotracers : [ 18 F]FDG (210), [ 11 C]PiB (51), and [ 18 F]florbetapir (98). The comparison to AC with a gold standard CT was performed both globally and regionally, with a special focus on robustness and outlier analysis. Results The average performance in PET tracer uptake was within ±5% of CT for all of the proposed methods, with the average±SD global percentage bias in PET FDG uptake for each method being: MR-AC DIXON (−11.3±3.5)%, MR-AC UTE (−5.7±2.0)%, MR-AC ONTARIO (−4.3±3.6)%, MR-AC MUNICH (3.7±2.1)%, MR-AC MLAA (−1.9±2.6)%, MR-AC SEGBONE (−1.7±3.6)%, MR-AC UCL (0.8±1.2)%, MR-AC CAR-RiDR (−0.4±1.9)%, MR-AC MAXPROB (−0.4±1.6)%, MR-AC BOSTON (−0.3±1.8)%, and MR-AC RESOLUTE (0.3±1.7)%, ordered by average bias. The overall best performing methods (MR-AC BOSTON , MR-AC MAXPROB , MR-AC RESOLUTE and MR-AC UCL , ordered alphabetically) showed regional average errors within ±3% of PET with CT-AC in all regions of the brain with FDG, and the same four methods, as well as MR-AC CAR-RiDR , showed that for 95% of the patients, 95% of brain voxels had an uptake that deviated by less than 15% from the reference. Comparable performance was obtained with PiB and florbetapir. Conclusions All of the proposed novel methods have an average global performance within likely acceptable limits (±5% of CT-based reference), and the main difference among the methods was found in the robustness, outlier analysis, and clinical feasibility. Overall, the best performing methods were MR-ACBOSTON, MR-ACMAXPROB, MR-ACRESOLUTE and MR-ACUCL, ordered alphabetically. These methods all minimized the number of outliers, standard deviation, and average global and local error. The methods MR-ACMUNICH and MR-ACCAR-RiDR were both within acceptable quantitative limits, so these methods should be considered if processing time is a factor. The method MR-ACSEGBONE also demonstrates promising results, and performs well within the likely acceptable quantitative limits. For clinical routine scans where processing time can be a key factor, this vendor-provided solution currently outperforms most methods. With the performance of the methods presented here, it may be concluded that the challenge of improving the accuracy of MR-AC in adult brains with normal anatomy has been solved to a quantitatively acceptable degree, which is smaller than the quantification reproducibility in PET imaging .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Law, I., Albert, N. L., Arbizu, J., Boellaard, R., Drzezga, A., Galldiks, N., la Fougère, C., Langen, K.-J., Lopci, E., Lowe, V., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4207-9 · Cited by 556
Self-citationAdvances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Deep Learning MR Imaging–based Attenuation Correction for PET/MR Imaging
Liu, F., Jang, H., Kijowski, R., Bradshaw, T., & McMillan, A. B. (2018) · Radiology · doi:10.1148/radiol.2017170700 · Cited by 412
EANM procedure guidelines for brain PET imaging using [18F]FDG, version 3
Guedj, E., Varrone, A., Boellaard, R., Albert, N. L., Barthel, H., van Berckel, B., Brendel, M., Cecchin, D., Ekmekcioglu, O., Garibotto, V., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05603-w · Cited by 300
Self-citationMaturation of the human striatal dopamine system revealed by PET and quantitative MRI
Larsen, B., Olafsson, V., Calabro, F., Laymon, C., Tervo-Clemmens, B., Campbell, E., Minhas, D., Montez, D., Price, J., & Luna, B. (2020) · Nature Communications · doi:10.1038/s41467-020-14693-3 · Cited by 107
Metadata
- Authors
- Ladefoged, C. N., Law, I., Anazodo, U., St. Lawrence, K., Izquierdo-Garcia, D., Catana, C., Burgos, N., Cardoso, M. J., Ourselin, S., Hutton, B., Mérida, I., Costes, N., Hammers, A., Benoit, D., Holm, S., Juttukonda, M., An, H., Cabello, J., Lukas, M., Nekolla, S., Ziegler, S., Fenchel, M., Jakoby, B., Casey, M. E., Benzinger, T., Højgaard, L., Hansen, A. E., & Andersen, F. L.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 147
- Pages
- 346-359
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2565897211
- Cited by
- 229
- References
- 0
- FWCI
- 19.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A multi-centre evaluation of eleven clinically feasible brain PET/MRI attenuation correction techniques using a large cohort of patients. https://app.cochat.ai/papers/10.1016/j.neuroimage.2016.12.010
- The paper
- Ladefoged, C. N., Law, I., Anazodo, U., St. Lawrence, K., Izquierdo-Garcia, D., Catana, C., Burgos, N., Cardoso, M. J., Ourselin, S., Hutton, B., Mérida, I., Costes, N., Hammers, A., Benoit, D., Holm, S., Juttukonda, M., An, H., Cabello, J., Lukas, M., . . . Andersen, F. L. (2017). A multi-centre evaluation of eleven clinically feasible brain PET/MRI attenuation correction techniques using a large cohort of patients. NeuroImage. https://doi.org/10.1016/j.neuroimage.2016.12.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.