The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Imaging of non-tumorous and tumorous human brain tissues with full-field optical coherence tomography
Open accessAbstract
A prospective study was performed on neurosurgical samples from 18 patients to evaluate the use of full-field optical coherence tomography (FF-OCT) in brain tumor diagnosis. FF-OCT captures en face slices of tissue samples at 1 μm resolution in 3D to a penetration depth of around 200 μm. A 1 cm(2) specimen is scanned at a single depth and processed in about 5 min. This rapid imaging process is non-invasive and requires neither contrast agent injection nor tissue preparation, which makes it particularly well suited to medical imaging applications. Temporal chronic epileptic parenchyma and brain tumors such as meningiomas, low-grade and high-grade gliomas, and choroid plexus papilloma were imaged. A subpopulation of neurons, myelin fibers and CNS vasculature were clearly identified. Cortex could be discriminated from white matter, but individual glial cells such as astrocytes (normal or reactive) or oligodendrocytes were not observable. This study reports for the first time on the feasibility of using FF-OCT in a real-time manner as a label-free non-invasive imaging technique in an intraoperative neurosurgical clinical setting to assess tumorous glial and epileptic margins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Outcome after Language Mapping for Glioma Resection
Sanai, N., Mirzadeh, Z., & Berger, M. S. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa067819 · Cited by 1,065
Stummer, W., Novotny, A., Stepp, H., Goetz, C., Bise, K., & Reulen, H. J. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.6.1003 · Cited by 881 · cited 1×
“More complete resections of high-grade gliomas have been demonstrated using 5-ALA fluorescence guidance (Stummer et al., 2000), however brain parenchyma infiltrated by isolated tumor cells is not fluorescent, reducing the interest of this technique when resecting low-grade gliomas.”
Background
Cited by
Kut, C., Chaichana, K. L., Xi, J., Raza, S. M., Ye, X., McVeigh, E. R., Rodriguez, F. J., Quiñones-Hinojosa, A., & Li, X. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010611 · Cited by 323
Intratumoral heterogeneity in glioblastoma: don't forget the peritumoral brain zone
Lemée, J.-M., Clavreul, A., & Menei, P. (2015) · Neuro-Oncology · doi:10.1093/neuonc/nov119 · Cited by 295
Metadata
- Authors
- Assayag, O., Grieve, K., Devaux, B., Harms, F., Pallud, J., Chretien, F., Boccara, C., & Varlet, P.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2013
- Volume
- 2
- Pages
- 549-557
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2167691746
- Cited by
- 168
- References
- 2
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging of non-tumorous and tumorous human brain tissues with full-field optical coherence tomography. https://app.cochat.ai/papers/10.1016/j.nicl.2013.04.005
- The paper
- Assayag, O., Grieve, K., Devaux, B., Harms, F., Pallud, J., Chretien, F., Boccara, C., & Varlet, P. (2013). Imaging of non-tumorous and tumorous human brain tissues with full-field optical coherence tomography. NeuroImage: Clinical. https://doi.org/10.1016/j.nicl.2013.04.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.