Volume of interest-based [18F]fluorodeoxyglucose PET discriminates MCI converting to Alzheimer's disease from healthy controls. A European Alzheimer's Disease Consortium (EADC) study
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
An emerging issue in neuroimaging is to assess the diagnostic reliability of PET and its application in clinical practice. We aimed at assessing the accuracy of brain FDG-PET in discriminating patients with MCI due to Alzheimer's disease and healthy controls. Sixty-two patients with amnestic MCI and 109 healthy subjects recruited in five centers of the European AD Consortium were enrolled. Group analysis was performed by SPM8 to confirm metabolic differences. Discriminant analyses were then carried out using the mean FDG uptake values normalized to the cerebellum computed in 45 anatomical volumes of interest (VOIs) in each hemisphere (90 VOIs) as defined in the Automated Anatomical Labeling (AAL) Atlas and on 12 meta-VOIs, bilaterally, obtained merging VOIs with similar anatomo-functional characteristics. Further, asymmetry indexes were calculated for both datasets. Accuracy of discrimination by a Support Vector Machine and the AAL VOIs was tested against a validated method (PALZ). At the voxel level SMP8 showed a relative hypometabolism in the bilateral precuneus, and posterior cingulate, temporo-parietal and frontal cortices. Discriminant analysis classified subjects with an accuracy ranging between .91 and .83 as a function of data organization. The best values were obtained from a subset of 6 meta-VOIs plus 6 asymmetry values reaching an area under the ROC curve of .947, significantly larger than the one obtained by the PALZ score. High accuracy in discriminating MCI converters from healthy controls was reached by a non-linear classifier based on SVM applied on predefined anatomo-functional regions and inter-hemispheric asymmetries. Data pre-processing was automated and simplified by an in-house created Matlab-based script encouraging its routine clinical use. Further validation toward nonconverter MCI patients with adequately long follow-up is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Albert, M. S., DeKosky, S. T., Dickson, D., Dubois, B., Feldman, H. H., Fox, N. C., Gamst, A., Holtzman, D. M., Jagust, W. J., Petersen, R. C., et al. (2011) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.03.008 · Cited by 10,152
Research criteria for the diagnosis of Alzheimer's disease: revising the NINCDS–ADRDA criteria
Dubois, B., Feldman, H. H., Jacova, C., DeKosky, S. T., Barberger-Gateau, P., Cummings, J., Delacourte, A., Galasko, D., Gauthier, S., Jicha, G., et al. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70178-3 · Cited by 4,411
Advancing research diagnostic criteria for Alzheimer's disease: the IWG-2 criteria
Dubois, B., Feldman, H. H., Jacova, C., Hampel, H., Molinuevo, J. L., Blennow, K., DeKosky, S. T., Gauthier, S., Selkoe, D., Bateman, R., et al. (2014) · The Lancet Neurology · doi:10.1016/s1474-4422(14)70090-0 · Cited by 3,321 · cited 1×
“…been included in the NIA–AA diagnostic criteria of Mild Cognitive Impairment (MCI) due to AD (Albert et al., 2011; Sperling et al., 2011) while the recently proposed IWG-2 research criteria hypothesize its role as a disease evolution rather than as a pure diagnostic biomarker (Dubois et al., 2014).”
Self-citationThe diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261 · cited 2×
“…(−LR) likelihood ratios were estimated according to the Simel method (Simel et al., 1991); CIs for the odds ratio were estimated by the conventional log-transform method (Glas et al., 2003) while CIs for the ROC-AUC were estimated by the bootstrap method described by Qin and Hotilovac (2008).”
Revising the definition of Alzheimer's disease: a new lexicon
Dubois, B., Feldman, H. H., Jacova, C., Cummings, J. L., DeKosky, S. T., Barberger-Gateau, P., Delacourte, A., Frisoni, G., Fox, N. C., Galasko, D., et al. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70223-4 · Cited by 1,869 · cited 1×
“…of Alzheimer3s Disease (AD) by the International Working Group (IWG) in 2007 and 2010 (Dubois et al., 2007; Dubois et al., 2010) and in the new diagnostic criteria of AD by the National Institute of Aging–Alzheimer Association (NIA–AA) (McKhann et al.,…”
Self-citationLikelihood ratios with confidence: Sample size estimation for diagnostic test studies
Simel, D. L., Samsa, G. P., & Matchar, D. B. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90128-v · Cited by 932 · cited 2×
“…and accuracy (Brown et al., 2001); CIs for positive (+LR) and negative (−LR) likelihood ratios were estimated according to the Simel method (Simel et al., 1991); CIs for the odds ratio were estimated by the conventional log-transform method (Glas et al., 2003) while CIs for the ROC-AUC…”
Discrimination between Alzheimer dementia and controls by automated analysis of multicenter FDG PET
Herholz, K., Salmon, E., Perani, D., Baron, J.-C., Holthoff, V., Frölich, L., Schönknecht, P., Ito, K., Mielke, R., & Kalbe, E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1208 · Cited by 832
FDG-PET improves accuracy in distinguishing frontotemporal dementia and Alzheimer's disease
Foster, N. L., Heidebrink, J. L., Clark, C. M., Jagust, W. J., Arnold, S. E., Barbas, N. R., DeCarli, C. S., Scott Turner, R., Koeppe, R. A., Higdon, R., et al. (2007) · Brain · doi:10.1093/brain/awm177 · Cited by 608 · cited 1×
“The commonest way is the visual reading that is the cornerstone of any report but it may not be accurate enough (Foster et al., 2007; Patterson et al., 2010) particularly at the early stages of the disease (i.e. MCI) or when expert readers are not available on site.”
Review and Meta-Analysis of Biomarkers and Diagnostic Imaging in Alzheimer's Disease
Bloudek, L. M., Spackman, D. E., Blankenburg, M., & Sullivan, S. D. (2011) · Journal of Alzheimer’s Disease · doi:10.3233/jad-2011-110458 · Cited by 282
Cited by
Rathore, S., Habes, M., Iftikhar, M. A., Shacklett, A., & Davatzikos, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.03.057 · Cited by 622
“A majority of the reviewed studies used a Gaussian kernel of 8 mm for both structural MRI (Misra et al., 2009; Moradi et al., 2015) and FDG-PET (Gray et al., 2013; Pagani et al., 2015; Zhang et al., 2011; Zhu et al., 2014).”
InfluentialCroteau, E., Castellano, C. A., Fortier, M., Bocti, C., Fulop, T., Paquet, N., & Cunnane, S. C. (2018) · Experimental Gerontology · doi:10.1016/j.exger.2017.07.004 · Cited by 258
Brain fluorodeoxyglucose (FDG) PET in dementia
Kato, T., Inui, Y., Nakamura, A., & Ito, K. (2016) · Ageing Research Reviews · doi:10.1016/j.arr.2016.02.003 · Cited by 236
Nobili, F., Arbizu, J., Bouwman, F., Drzezga, A., Agosta, F., Nestor, P., Walker, Z., Boccardi, M., & the EANM‐EAN Task Force for the Prescription of FDG‐PET for Dementing Neurodegenerative Disorders (2018) · European Journal of Neurology · doi:10.1111/ene.13728 · Cited by 211
Self-citationA Cochrane review on brain [18F]FDG PET in dementia: limitations and future perspectives
On behalf of the European Association of Nuclear Medicine, Morbelli, S., Garibotto, V., Van De Giessen, E., Arbizu, J., Chételat, G., Drezgza, A., Hesse, S., Lammertsma, A. A., Law, I., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3098-2 · Cited by 61
“Three of these 19 studies used a normal reference population as the source of normative data, an approach that was not considered in the Cochrane review [38, 39, 41].”
BackgroundSelf-citation
Metadata
- Authors
- Pagani, M., De Carli, F., Morbelli, S., Öberg, J., Chincarini, A., Frisoni, G. B., Galluzzi, S., Perneczky, R., Drzezga, A., van Berckel, B. N. M., Ossenkoppele, R., Didic, M., Guedj, E., Brugnolo, A., Picco, A., Arnaldi, D., Ferrara, M., Buschiazzo, A., Sambuceti, G., & Nobili, F.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2015
- Volume
- 7
- Pages
- 34-42
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W2086216368
- Cited by
- 96
- References
- 13
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volume of interest-based [18F]fluorodeoxyglucose PET discriminates MCI converting to Alzheimer's disease from healthy controls. A European Alzheimer's Disease Consortium (EADC) study. https://app.cochat.ai/papers/10.1016/j.nicl.2014.11.007
- The paper
- Pagani, M., De Carli, F., Morbelli, S., Öberg, J., Chincarini, A., Frisoni, G. B., Galluzzi, S., Perneczky, R., Drzezga, A., van Berckel, B. N. M., Ossenkoppele, R., Didic, M., Guedj, E., Brugnolo, A., Picco, A., Arnaldi, D., Ferrara, M., Buschiazzo, A., Sambuceti, G., & Nobili, F. (2015). Volume of interest-based [18F]fluorodeoxyglucose PET discriminates MCI converting to Alzheimer's disease from healthy controls. A European Alzheimer's Disease Consortium (EADC) study. NeuroImage: Clinical. https://doi.org/10.1016/j.nicl.2014.11.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.