Rotation-invariant multi-contrast non-local means for MS lesion segmentation
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Multiple sclerosis (MS) lesion segmentation is crucial for evaluating disease burden, determining disease progression and measuring the impact of new clinical treatments. MS lesions can vary in size, location and intensity, making automatic segmentation challenging. In this paper, we propose a new supervised method to segment MS lesions from 3D magnetic resonance (MR) images using non-local means (NLM). The method uses a multi-channel and rotation-invariant distance measure to account for the diversity of MS lesions. The proposed segmentation method, rotation-invariant multi-contrast non-local means segmentation (RMNMS), captures the MS lesion spatial distribution and can accurately and robustly identify lesions regardless of their orientation, shape or size. An internal validation on a large clinical magnetic resonance imaging (MRI) dataset of MS patients demonstrated a good similarity measure result (Dice similarity = 60.1% and sensitivity = 75.4%), a strong correlation between expert and automatic lesion load volumes (R(2) = 0.91), and a strong ability to detect lesions of different sizes and in varying spatial locations (lesion detection rate = 79.8%). On the independent MS Grand Challenge (MSGC) dataset validation, our method provided competitive results with state-of-the-art supervised and unsupervised methods. Qualitative visual and quantitative voxel- and lesion-wise evaluations demonstrated the accuracy of RMNMS method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostic criteria for multiple sclerosis: 2010 revisions to the McDonald criteria
Polman, C. H., Reingold, S. C., Banwell, B., Clanet, M., Cohen, J. A., Filippi, M., Fujihara, K., Havrdova, E., Hutchinson, M., Kappos, L., et al. (2011) · Annals of Neurology · doi:10.1002/ana.22366 · Cited by 9,802
Unbiased average age-appropriate atlases for pediatric studies
Fonov, V., Evans, A. C., Botteron, K., Almli, C. R., McKinstry, R. C., & Collins, D. L. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.07.033 · Cited by 2,290 · cited 2×
“Therefore, in this article we focus on two clinical datasets, an RRMS multi-center clinical dataset and the MICCAI (2008) MS Grand Challenge dataset (Styner et al., 2008).”
Self-citationHistopathologic correlate of hypointense lesions on T1-weighted spin-echo MRI in multiple sclerosis
van Walderveen, M. A. A., Kamphorst, W., Scheltens, P., van Waesberghe, J. H. T. M., Ravid, R., Valk, J., Polman, C. H., & Barkhof, F. (1998) · Neurology · doi:10.1212/wnl.50.5.1282 · Cited by 656 · cited 1×
“On T1W images, lesions appear hypointense but present a larger intensity variability which might re fl ect the different sub-types of lesion such as the so-called “ black hole ” associated with irreversible tissue damage (van Walderveen et al. 1998).”
The contribution of magnetic resonance imaging to the diagnosis of multiple sclerosis
Fazekas, F., Barkhof, F., Filippi, M., Grossman, R. I., Li, D. K. B., McDonald, W. I., McFarland, H. F., Paty, D. W., Simon, J. H., Wolinsky, J. S., et al. (1999) · Neurology · doi:10.1212/wnl.53.3.448 · Cited by 287 · cited 1×
“…resonance imaging (MRI) is sensitive to in fl ammatory and demyelinat-ingchanges, it is often used to monitor, identify and quantify MS lesions (Fazekas et al., 1999) that are hyperintense on T2-weighted (T2W) magnetic resonance (MR) images and may become hypointense on T1-weighted (T1W)…”
Cited by
Brosch, T., Tang, L. Y. W., Yoo, Y., Li, D. K. B., Traboulsee, A., & Tam, R. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528821 · Cited by 460
“Current supervised approaches typically start with a set of features, which can range from small and simple to large and highly variable, and are either predefined by the user [13], [14], [37] or gathered in a feature extraction step such as by deep”
BackgroundMethodValverde, S., Cabezas, M., Roura, E., González-Villà, S., Pareto, D., Vilanova, J. C., Ramió-Torrentà, L., Rovira, À., Oliver, A., & Lladó, X. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.04.034 · Cited by 392
HeMIS: Hetero-Modal Image Segmentation
Havaei, M., Guizard, N., Chapados, N., & Bengio, Y. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_54 · Cited by 332
“…shown excellent results in structural segmentation when using non-linear registration [11]; when combined with non-local approaches they have proven effective in segmenting diffuse and sparse pathologies (ie. multiple sclerosis (MS) lesions [7]) as well as more complex multi-label pathology (ie.”
BackgroundSelf-citationGros, C., De Leener, B., Badji, A., Maranzano, J., Eden, D., Dupont, S. M., Talbott, J., Zhuoquiong, R., Liu, Y., Granberg, T., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.081 · Cited by 289
Hashemi, S. R., Mohseni Salehi, S. S., Erdogmus, D., Prabhu, S. P., Warfield, S. K., & Gholipour, A. (2019) · IEEE Access · doi:10.1109/access.2018.2886371 · Cited by 212
“Classic supervised methods for MS lesion segmentation involved decision random forests [19], [20], non-local means [21], [22], and combined inference from patient and healthy populations [23].”
Metadata
- Authors
- Guizard, N., Coupé, P., Fonov, V. S., Manjón, J. V., Arnold, D. L., & Collins, D. L.
- Venue
- NeuroImage: Clinical
- Publisher
- Elsevier BV
- Published
- 2015
- Volume
- 8
- Pages
- 376-389
- ISSN
- 2213-1582 (ISSN-L)
- OpenAlex
- W341325887
- Cited by
- 73
- References
- 4
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.