CoChat

White matter hyperintensity quantification in large-scale clinical acute ischemic stroke cohorts – The MRI-GENIE study

Open access
Schirmer, Markus D., Dalca, Adrian V., Sridharan, Ramesh, Giese, Anne-Katrin, Donahue, Kathleen L., Nardin, Marco J., Mocking, Steven J.T., McIntosh, Elissa C., Frid, Petrea, Wasselius, Johan, Cole, John W., Holmegaard, Lukas, Jern, Christina, Jimenez-Conde, Jordi, Lemmens, Robin, Lindgren, Arne G., Meschia, James F., Roquer, Jaume, Rundek, Tatjana, Sacco, Ralph L., Schmidt, Reinhold, Sharma, Pankaj, Slowik, Agnieszka, Thijs, Vincent, Woo, Daniel, Vagal, Achala, Xu, Huichun, Kittner, Steven J., McArdle, Patrick F., Mitchell, Braxton D., Rosand, Jonathan, Worrall, Bradford B., Wu, Ona, Golland, Polina, Rost, Natalia S. · 2019 · NeuroImage: Clinical
Cited by 63

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

White matter hyperintensity (WMH) burden is a critically important cerebrovascular phenotype linked to prediction of diagnosis and prognosis of diseases, such as acute ischemic stroke (AIS). However, current approaches to its quantification on clinical MRI often rely on time intensive manual delineation of the disease on T2 fluid attenuated inverse recovery (FLAIR), which hinders high-throughput analyses such as genetic discovery. In this work, we present a fully automated pipeline for quantification of WMH in clinical large-scale studies of AIS. The pipeline incorporates automated brain extraction, intensity normalization and WMH segmentation using spatial priors. We first propose a brain extraction algorithm based on a fully convolutional deep learning architecture, specifically designed for clinical FLAIR images. We demonstrate that our method for brain extraction outperforms two commonly used and publicly available methods on clinical quality images in a set of 144 subject scans across 12 acquisition centers, based on dice coefficient (median 0.95; inter-quartile range 0.94-0.95; p < 0.01) and Pearson correlation of total brain volume (r = 0.90). Subsequently, we apply it to the large-scale clinical multi-site MRI-GENIE study (N = 2783) and identify a decrease in total brain volume of -2.4 cc/year. Additionally, we show that the resulting total brain volumes can successfully be used for quality control of image preprocessing. Finally, we obtain WMH volumes by building on an existing automatic WMH segmentation algorithm that delineates and distinguishes between different cerebrovascular pathologies. The learning method mimics expert knowledge of the spatial distribution of the WMH burden using a convolutional auto-encoder. This enables successful computation of WMH volumes of 2533 clinical AIS patients. We utilize these results to demonstrate the increase of WMH burden with age (0.950 cc/year) and show that single site estimates can be biased by the number of subjects recruited.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nicl.2019.101884

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 63

Metadata

Authors
Schirmer, M. D., Dalca, A. V., Sridharan, R., Giese, A.-K., Donahue, K. L., Nardin, M. J., Mocking, S. J. T., McIntosh, E. C., Frid, P., Wasselius, J., Cole, J. W., Holmegaard, L., Jern, C., Jimenez-Conde, J., Lemmens, R., Lindgren, A. G., Meschia, J. F., Roquer, J., Rundek, T., Sacco, R. L., Schmidt, R., Sharma, P., Slowik, A., Thijs, V., Woo, D., Vagal, A., Xu, H., Kittner, S. J., McArdle, P. F., Mitchell, B. D., Rosand, J., Worrall, B. B., Wu, O., Golland, P., & Rost, N. S.
Venue
NeuroImage: Clinical
Publisher
Elsevier BV
Published
2019
Volume
23
Pages
101884
ISSN
2213-1582 (ISSN-L)
OpenAlex
W2951817526
Cited by
63
References
5
FWCI
4.02
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: White matter hyperintensity quantification in large-scale clinical acute ischemic stroke cohorts – The MRI-GENIE study. https://app.cochat.ai/papers/10.1016/j.nicl.2019.101884
The paper
Schirmer, M. D., Dalca, A. V., Sridharan, R., Giese, A.-K., Donahue, K. L., Nardin, M. J., Mocking, S. J. T., McIntosh, E. C., Frid, P., Wasselius, J., Cole, J. W., Holmegaard, L., Jern, C., Jimenez-Conde, J., Lemmens, R., Lindgren, A. G., Meschia, J. F., Roquer, J., Rundek, T., . . . Rost, N. S. (2019). White matter hyperintensity quantification in large-scale clinical acute ischemic stroke cohorts – The MRI-GENIE study. NeuroImage: Clinical. https://doi.org/10.1016/j.nicl.2019.101884

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.