Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 280

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

A bremsstrahlung gamma-ray source based on stable ionization injection of electrons into a laser wakefield accelerator

Open access
Döpp, A., Guillaume, E., Thaury, C., Lifschitz, A., Sylla, F., Goddet, J-P., Tafzi, A., Iaquanello, G., Lefrou, T., Rousseau, P., Conejero, E., Ruiz, C., Ta Phuoc, K., Malka, V.·2016·Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Abstract

Abstract Laser wakefield acceleration permits the generation of ultra-short, high-brightness relativistic electron beams on a millimeter scale. While those features are of interest for many applications, the source remains constraint by the poor stability of the electron injection process. Here we present results on injection and acceleration of electrons in pure nitrogen and argon. We observe stable, continuous ionization-induced injection of electrons into the wakefield for laser powers exceeding a threshold of 7 TW. The beam charge scales approximately with the laser energy and is limited by beam loading. For 40 TW laser pulses we measure a maximum charge of almost 1 nC per shot, originating mostly from electrons of less than 10 MeV energy. The relatively low energy, the high charge and its stability make this source well-suited for applications such as non-destructive testing. Hence, we demonstrate the production of energetic radiation via bremsstrahlung conversion at 1 Hz repetition rate. In accordance with Geant4 Monte-Carlo simulations, we measure a γ-ray source size of less than 100 μm for a 0.5 mm tantalum converter placed at 2 mm from the accelerator exit. Furthermore we present radiographs of image quality indicators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nima.2016.01.086

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 280

Metadata

Authors
Döpp, A., Guillaume, E., Thaury, C., Lifschitz, A., Sylla, F., Goddet, J.-P., Tafzi, A., Iaquanello, G., Lefrou, T., Rousseau, P., Conejero, E., Ruiz, C., Ta Phuoc, K., & Malka, V.
Venue
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Publisher
Elsevier BV
Published
2016-09
Volume
830
Pages
515-519
ISSN
0168-9002 (ISSN-L)
OpenAlex
W2254920216
Cited by
280
References
32
FWCI
2.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A bremsstrahlung gamma-ray source based on stable ionization injection of electrons into a laser wakefield accelerator. https://app.cochat.ai/papers/10.1016/j.nima.2016.01.086
The paper
Döpp, A., Guillaume, E., Thaury, C., Lifschitz, A., Sylla, F., Goddet, J.-P., Tafzi, A., Iaquanello, G., Lefrou, T., Rousseau, P., Conejero, E., Ruiz, C., Ta Phuoc, K., & Malka, V. (2016). A bremsstrahlung gamma-ray source based on stable ionization injection of electrons into a laser wakefield accelerator. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/j.nima.2016.01.086

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.