The DESY II test beam facility
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Abstract DESY Hamburg operates a test beam facility with three independent beam lines at the DESY II synchrotron. It is world-wide one of very few facilities providing test beams in the GeV range. To this end, it offers electron/positron beams with user-selectable momenta from 1-6 GeV/c. The available infrastructure for the users is unique, including a high field solenoidal magnet and permanently installed high-precision pixel beam telescopes. This publication gives a detailed description of the facility, the available infrastructure, and the simulated and measured performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946 · cited 8×
“A geantino is a virtual particle for transportation processes in Geant4 simulations [30].”
MethodInfluentialAllison, J., Amako, K., Apostolakis, J., Arce, P., Asai, M., Aso, T., Bagli, E., Bagulya, A., Banerjee, S., Barrand, G., et al. (2016) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2016.06.125 · Cited by 4,194
The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
Böhlen, T. T., Cerutti, F., Chin, M. P. W., Fassò, A., Ferrari, A., Ortega, P. G., Mairani, A., Sala, P. R., Smirnov, G., & Vlachoudis, V. (2014) · Nuclear Data Sheets · doi:10.1016/j.nds.2014.07.049 · Cited by 1,758 · cited 4×
“The resulting radiation doses of a FLUKA [12, 13] simulation, for the example of a 10 cm thick lead block array in front of a test beam area wall as in TB22 are presented in the following.”
MethodInfluential
Metadata
- Authors
- Diener, R., Dreyling-Eschweiler, J., Ehrlichmann, H., Gregor, I. M., Kötz, U., Krämer, U., Meyners, N., Potylitsina-Kube, N., Schütz, A., Schütze, P., & Stanitzki, M.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 2019-04
- Volume
- 922
- Pages
- 265-286
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W2731019424
- Cited by
- 219
- References
- 4
- FWCI
- 9.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The DESY II test beam facility. https://app.cochat.ai/papers/10.1016/j.nima.2018.11.133
- The paper
- Diener, R., Dreyling-Eschweiler, J., Ehrlichmann, H., Gregor, I. M., Kötz, U., Krämer, U., Meyners, N., Potylitsina-Kube, N., Schütz, A., Schütze, P., & Stanitzki, M. (2019). The DESY II test beam facility. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/j.nima.2018.11.133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.