The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Design and construction of the new BESIII endcap Time-of-Flight system with MRPC Technology
Abstract
Abstract In order to improve the particle identification capability, the Beijing Spectrometer (BESIII) collaboration has upgraded the End-cap Time-Of-Flight detector (ETOF) based on Multi-gap Resistive Plate Chamber (MRPC) technology. In this paper, the design and engineering development of each part of the project are reported. There are 72 MRPC modules, forming 2 rings. Adjacent modules are staggered placed to avoid dead regions. Each MRPC module contains 12-layer thin gaps to get fast signals with high efficiency and 12 strips to readout the induced signals from two ends, effectively reducing the timing uncertainties from the scattering and positioning. Also, the analog–digital conversion is done near the MRPC and only the digital signals are transferred through thin coax cables, ensuring good signal-to-noise ratio. The complex electromagnetic noises in the BESIII colliding area are well shielded to protect the tiny signals from the MRPC. After careful correction and calibration, the total time resolution of upgraded ETOF system is 65ps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
Design and construction of the BESIII detector
Ablikim, M., An, Z. H., Bai, J. Z., Berger, N., Bian, J. M., Cai, X., Cao, G. F., Cao, X. X., Chang, J. F., Chen, C., et al. (2010) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2009.12.050 · Cited by 1,243
Self-citation
Metadata
- Authors
- Cao, P., Chen, H. F., Chen, M. M., Dai, H. L., Heng, Y. K., Ji, X. L., Jiang, X. S., Li, C., Li, X., Liu, S. B., Liu, Z., Luo, X. L., Ma, X. Y., Shao, M., Sun, S. S., Sun, Y. J., Tang, Z. B., Wang, X. Z., Wu, Z., Xu, M. H., Yang, R. X., Ye, M., Zhang, J., Zhang, Y. H., & Zhao, J. Z.
- Venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Publisher
- Elsevier BV
- Published
- 2020-02
- Volume
- 953
- Pages
- 163053
- ISSN
- 0168-9002 (ISSN-L)
- OpenAlex
- W2989325459
- Cited by
- 265
- References
- 3
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and construction of the new BESIII endcap Time-of-Flight system with MRPC Technology. https://app.cochat.ai/papers/10.1016/j.nima.2019.163053
- The paper
- Cao, P., Chen, H. F., Chen, M. M., Dai, H. L., Heng, Y. K., Ji, X. L., Jiang, X. S., Li, C., Li, X., Liu, S. B., Liu, Z., Luo, X. L., Ma, X. Y., Shao, M., Sun, S. S., Sun, Y. J., Tang, Z. B., Wang, X. Z., Wu, Z., . . . Zhao, J. Z. (2020). Design and construction of the new BESIII endcap Time-of-Flight system with MRPC Technology. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/j.nima.2019.163053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.