Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 265

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Design and construction of the new BESIII endcap Time-of-Flight system with MRPC Technology

Cao, P., Chen, H.F., Chen, M.M., Dai, H.L., Heng, Y.K., Ji, X.L., Jiang, X.S., Li, C., Li, X., Liu, S.B., Liu, Z., Luo, X.L., Ma, X.Y., Shao, M., Sun, S.S., Sun, Y.J., Tang, Z.B., Wang, X.Z., Wu, Z., Xu, M.H., Yang, R.X., Ye, M., Zhang, J., Zhang, Y.H., Zhao, J.Z.·2020·Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Abstract

Abstract In order to improve the particle identification capability, the Beijing Spectrometer (BESIII) collaboration has upgraded the End-cap Time-Of-Flight detector (ETOF) based on Multi-gap Resistive Plate Chamber (MRPC) technology. In this paper, the design and engineering development of each part of the project are reported. There are 72 MRPC modules, forming 2 rings. Adjacent modules are staggered placed to avoid dead regions. Each MRPC module contains 12-layer thin gaps to get fast signals with high efficiency and 12 strips to readout the induced signals from two ends, effectively reducing the timing uncertainties from the scattering and positioning. Also, the analog–digital conversion is done near the MRPC and only the digital signals are transferred through thin coax cables, ensuring good signal-to-noise ratio. The complex electromagnetic noises in the BESIII colliding area are well shielded to protect the tiny signals from the MRPC. After careful correction and calibration, the total time resolution of upgraded ETOF system is 65ps.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nima.2019.163053

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Metadata

Authors
Cao, P., Chen, H. F., Chen, M. M., Dai, H. L., Heng, Y. K., Ji, X. L., Jiang, X. S., Li, C., Li, X., Liu, S. B., Liu, Z., Luo, X. L., Ma, X. Y., Shao, M., Sun, S. S., Sun, Y. J., Tang, Z. B., Wang, X. Z., Wu, Z., Xu, M. H., Yang, R. X., Ye, M., Zhang, J., Zhang, Y. H., & Zhao, J. Z.
Venue
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Publisher
Elsevier BV
Published
2020-02
Volume
953
Pages
163053
ISSN
0168-9002 (ISSN-L)
OpenAlex
W2989325459
Cited by
265
References
3
FWCI
5.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Design and construction of the new BESIII endcap Time-of-Flight system with MRPC Technology. https://app.cochat.ai/papers/10.1016/j.nima.2019.163053
The paper
Cao, P., Chen, H. F., Chen, M. M., Dai, H. L., Heng, Y. K., Ji, X. L., Jiang, X. S., Li, C., Li, X., Liu, S. B., Liu, Z., Luo, X. L., Ma, X. Y., Shao, M., Sun, S. S., Sun, Y. J., Tang, Z. B., Wang, X. Z., Wu, Z., . . . Zhao, J. Z. (2020). Design and construction of the new BESIII endcap Time-of-Flight system with MRPC Technology. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. https://doi.org/10.1016/j.nima.2019.163053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.