The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
The PyHST2 hybrid distributed code for high speed tomographic reconstruction with iterative reconstruction and a priori knowledge capabilities
Open accessAbstract
We present the PyHST2 code which is in service at ESRF for phase-contrast and absorption tomography. This code has been engineered to sustain the high data flow typical of the 3rd generation synchrotron facilities (10 terabytes per experiment) by adopting a distributed and pipelined architecture. The code implements, beside a default filtered backprojection reconstruction, iterative reconstruction techniques with a priori knowledge. These latter are used to improve the reconstruction quality or in order to reduce the required data volume or the deposited dose to the sample and reach a given quality goal. The implemented a priori knowledge techniques are based on the total variation penalization and a new recently found convex functional which is based on overlapping patches. We give details of the different methods and discuss how they are implemented in the PyHST2 code, which is distributed under free license. We provide methods for estimating, in the absence of ground-truth data, the optimal parameters values for a priori techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Image Denoising Via Sparse and Redundant Representations Over Learned Dictionaries
Elad, M., & Aharon, M. (2006) · IEEE Transactions on Image Processing · doi:10.1109/tip.2006.881969 · Cited by 5,321
An iterative thresholding algorithm for linear inverse problems with a sparsity constraint.
Daubechies, I., Defrise, M., & De Mol, C. (2004) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20042 · Cited by 4,958
chambolle (2004) · doi:10.1023/b:jmiv.0000011321.19549.88 · Cited by 3,227
Online Learning for Matrix Factorization and Sparse Coding
Mairal, J., Bach, F., Ponce, J., & Sapiro, G. (2009) · arXiv (Cornell University) · doi:10.48550/arxiv.0908.0050 · Cited by 2,258
Proximal Splitting Methods in Signal Processing
Combettes, P. L., & Pesquet, J.-C. (2011) · Springer Optimization and Its Applications · doi:10.1007/978-1-4419-9569-8_10 · Cited by 2,183
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Beck, A., & Teboulle, M. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028250 · Cited by 2,004
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
X-ray micro-tomography an attractive characterisation technique in materials science
Salvo, L., Cloetens, P., Maire, É., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/s0168-583x(02)01689-0 · Cited by 473
LAPACK: A Portable Linear Algebra Library for High-Performance Computers
Anderson, E., Bai, Z., Bischof, C. H., Demmel, J. W., Dongarra, J. J., Croz, J. D., Greenbaum, A., Hammarling, S. J., McKenney, A., & Sorensen, D. C. (1990) · Cited by 428
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
Jia, X., Lou, Y., Li, R., Song, W. Y., & Jiang, S. B. (2010) · Medical Physics · doi:10.1118/1.3371691 · Cited by 232
High-resolution, low-dose phase contrast X-ray tomography for 3D diagnosis of human breast cancers
Zhao, Y., Brun, E., Coan, P., Huang, Z., Sztrókay, A., Diemoz, P. C., Liebhardt, S., Mittone, A., Gasilov, S., Miao, J., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1204460109 · Cited by 195
Self-citationSparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
Parameter selection for total-variation-based image restoration using discrepancy principle
Wen, Y.-W., & Chan, R. H. (2012) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2181401 · Cited by 182
Sanchez, S., Ahlberg, P. E., Trinajstic, K. M., Mirone, A., & Tafforeau, P. (2012) · Microscopy and Microanalysis · doi:10.1017/s1431927612001079 · Cited by 163
Self-citationSelection of regularization parameter in total variation image restoration
Liao, H., Li, F., & Ng, M. K. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.002311 · Cited by 91
A hard x-ray nanoprobe for scanning and projection nanotomography
Bleuet, P., Cloetens, P., Gergaud, P., Mariolle, D., Chevalier, N., Tucoulou, R., Susini, J., & Chabli, A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3117489 · Cited by 85
Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography
Sidky, E. Y., Anastasio, M. A., & Pan, X. (2010) · Optics Express · doi:10.1364/oe.18.010404 · Cited by 49
A GPU-Based Architecture for Real-Time Data Assessment at Synchrotron Experiments
Chilingaryan, S. A., Mirone, A., Hammersley, A. P., et al. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2141686 · Cited by 46
Self-citation« Toumaï », Miocène supérieur du Tchad, le nouveau doyen du rameau humain
Brunet, M., Guy, F., Boisserie, J., Djimdoumalbaye, A., Lehmann, T., Lihoreau, F., Louchart, A., Schuster, M., Tafforeau, P., Likius, A., et al. (2004) · Comptes Rendus Palevol · doi:10.1016/j.crpv.2004.04.004 · Cited by 36
Self-citationMirone, A., Brun, E., & Coan, P. (2014) · PLoS ONE · doi:10.1371/journal.pone.0114325 · Cited by 21
Self-citation
Cited by
Fast and flexible X-ray tomography using the ASTRA toolbox
van Aarle, W., Palenstijn, W. J., Cant, J., Janssens, E., Bleichrodt, F., Dabravolski, A., De Beenhouwer, J., Joost Batenburg, K., & Sijbers, J. (2016) · Optics Express · doi:10.1364/oe.24.025129 · Cited by 1,036
TomoPy: a framework for the analysis of synchrotron tomographic data
Gürsoy, D., De Carlo, F., Xiao, X., & Jacobsen, C. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s1600577514013939 · Cited by 963
Tan, S., Shadike, Z., Li, J., Wang, X., Yang, Y., Lin, R., Cresce, A., Hu, J., Hunt, A., Waluyo, I., et al. (2022) · Nature Energy · doi:10.1038/s41560-022-01020-x · Cited by 414
Heterogeneous damage in Li-ion batteries: Experimental analysis and theoretical modeling
Xu, R., Yang, Y., Yin, F., Liu, P., Cloetens, P., Liu, Y., Lin, F., & Zhao, K. (2019) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2019.05.003 · Cited by 345
Walsh, C. L., Tafforeau, P., Wagner, W. L., Jafree, D. J., Bellier, A., Werlein, C., Kühnel, M. P., Boller, E., Walker-Samuel, S., Robertus, J. L., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01317-x · Cited by 321
Self-citation
Metadata
- Authors
- Mirone, A., Brun, E., Gouillart, E., Tafforeau, P., & Kieffer, J.
- Venue
- Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 324
- Pages
- 41-48
- ISSN
- 0168-583X (ISSN-L)
- OpenAlex
- W1998401010
- Cited by
- 525
- References
- 24
- FWCI
- 30.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.