The DOI matches its Crossref record.
Comparison of Retinal Nerve Fiber Layer Measurements Using Time Domain and Spectral Domain Optical Coherent Tomography
Open accessAbstract
Purpose To determine the agreement between peripapillary retinal nerve fiber layer (RNFL) thickness measurements from Stratus time domain optical coherence tomography (OCT) and Cirrus spectral domain OCT (Carl Zeiss Meditec, Dublin, CA) in normal subjects and glaucoma patients. Design Evaluation of diagnostic test or technology. Participants One hundred thirty eyes from 130 normal subjects and glaucoma patients were analyzed. The subjects were divided into Normal (n=29), Glaucoma Suspect (n=12), Mild Glaucoma (n=41), Moderate Glaucoma (n=18), and Severe Glaucoma (n=30) by visual field criteria. Methods Peripapillary RNFL thickness was measured with Stratus Fast RNFL and Cirrus 200 x 200 Optic Disc Scan on the same day in one eye of each subject to determine agreement. Two operators used the same instruments for all scans. Main Outcome Measures Student paired t-testing, Pearson’s correlation coefficient, and Bland-Altman analysis of RNFL thickness measurements. Results The average age of the glaucoma group was significantly older at 68.3±12.3 years versus 55.7±12.1 years. The average RNFL thickness (mean ± SD, in μm) for each severity group with Stratus OCT was 99.4 ± 13.2, 94.5 ± 15.0, 79.0 ± 14.5, 62.7 ± 10.2, and 51.0 ± 8.9, corresponding to normal, suspects, mild, moderate, and severe subjects, respectively. For Cirrus OCT, the corresponding measurements were 92.0 ± 10.8, 88.1 ± 13.5, 73.3 ± 11.8, 60.9 ± 8.3, and 55.3 ± 6.6. All Stratus-Cirrus differences were statistically significant by paired t-testing (p < 0.001) except for the moderate group (p = 0.11). For average RNFL, there was a highly significant linear relationship between Stratus minus Cirrus difference and RNFL thickness as well (p < 0.001). Bland-Altman plots showed that the systematic difference of Stratus measurements are smaller than Cirrus at thinner RNFL values but larger at thicker RNFL measurements. Conclusions RNFL thickness measurements between Stratus OCT and Cirrus OCT cannot be directly compared. Clinicians should be aware that measurements are generally higher with Stratus than Cirrus except when the RNFL is very thin as in severe glaucoma. This difference must be taken into account if comparing measurements made with a Stratus instrument to those of a Cirrus instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography: Imaging of the choroid and beyond
Mrejen, S., & Spaide, R. F. (2013) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.12.001 · Cited by 477
Linking structure and function in glaucoma
Harwerth, R. S., Wheat, J. L., Fredette, M. J., & Anderson, D. R. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2010.02.001 · Cited by 293
Ferrara, D., Waheed, N. K., & Duker, J. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.10.002 · Cited by 265
Zheng, C., Xie, X., Huang, L., Chen, B., Yang, J., Lu, J., Qiao, T., Fan, Z., & Zhang, M. (2020) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-019-04543-4 · Cited by 40
Metadata
- Authors
- Knight, O. J., Chang, R. T., Feuer, W. J., & Budenz, D. L.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 116
- Issue
- 7
- Pages
- 1271-1277
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2071304878
- Cited by
- 199
- References
- 0
- FWCI
- 28.83
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.