Neuroimaging in Patients Referred to a Neuro-ophthalmology Service
Open accessThe DOI matches its Crossref record.
Abstract
Objective Neuro-imaging studies are frequently ordered to investigate neuro-ophthalmic symptoms. When misused these studies are expensive and time-consuming. This study aimed to describe the type and frequency of neuro-imaging errors in patients referred to an academic neuro-ophthalmology service and to measure how frequently these neuro-imaging studies were re-interpreted. Design Prospective cohort study Participants 84 consecutive patients referred to an academic neuro-ophthalmology practice Methods From November 2009 through July 2010 we prospectively enrolled 84 consecutive new patients who had received a neuro-imaging study in the last 12 months specifically in evaluation of their presenting neuro-ophthalmic symptoms. Participants then underwent a complete neuro-ophthalmic evaluation followed by a review of prior neuro-imaging. Questions regarding appropriateness of the most recent imaging, concordance of radiological interpretation, and re-evaluation of referring diagnoses were answered by the attending physician. Main Outcome Measures 1. The frequency and types of errors committed in the utilization of neuro-imaging. 2. The frequency of re-interpretation of pre-referral neuro-imaging studies following neuro-ophthalmic history and examination. Results Most study participants (84.5%; 71/84) underwent magnetic resonance imaging (MRI) prior to referral; 15.5% (13/84) underwent only computed tomography (CT). The rate of sub-optimal neuro-imaging studies was 38.1% (32/84). The three most common reasons for sub-optimal studies were incomplete area of imaging (34.4%; 11/32), wrong study type (28.1%; 9/32), and poor image quality (21.9%; 7/32). 24 of 84 subjects (28.6%) required additional neuro-imaging. We agreed with the radiology interpretation of the prior neuro-imaging studies in the majority (77.4%; 65/84) of patients. The most common anatomic locations for discordance in interpretation were the intraorbital optic nerve (35%; 7/20) and the brainstem (20%; 4/20). Conclusions There was a high rate of sub-optimal neuro-imaging studies performed in patients referred to neuro-ophthalmology. These findings have significant implications given the increasing attention to resource utilization currently and in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Added value of double reading in diagnostic radiology,a systematic review
Geijer, H., & Geijer, M. (2018) · Insights into Imaging · doi:10.1007/s13244-018-0599-0 · Cited by 117
Patient harm due to diagnostic error of neuro-ophthalmologic conditions.
Stunkel, L., Sharma, R. A., Mackay, D. D., Wilson, B., Van Stavern, G. P., Newman, N. J., & Biousse, V. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2021.03.008 · Cited by 54
Referral patterns in neuro-ophthalmology
Stunkel, L., Mackay, D. D., Bruce, B. B., Newman, N. J., & Biousse, V. (2020) · Journal of Neuro-Ophthalmology · doi:10.1097/wno.0000000000000846 · Cited by 37
Diagnostic error and neuro-ophthalmology
Stunkel, L., Newman, N. J., & Biousse, V. (2019) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000635 · Cited by 29
Metadata
- Authors
- McClelland, C., Van Stavern, G. P., Shepherd, J. B., Gordon, M., & Huecker, J.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2012-08
- Volume
- 119
- Issue
- 8
- Pages
- 1701-1704
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W1559243569
- Cited by
- 23
- References
- 0
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.