Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Reticular Pseudodrusen

Open access
Finger, Robert P., Wu, Zhichao, Luu, Chi D., Kearney, Frances, Ayton, Lauren N., Lucci, Lucia M., Hubbard, William C., Hageman, Jill L., Hageman, Gregory S., Guymer, Robyn H. · 2014 · Ophthalmology

Abstract

Purpose To determine whether reticular pseudodrusen (RPD) confer an increased risk of progression to late-stage age-related macular degeneration (AMD) in fellow eyes of those recently diagnosed with unilateral choroidal neovascularization (CNV). Design Retrospective study Participants 200 consecutive participants with CNV secondary to AMD in one eye and no signs of late stage AMD in the fellow eye. Methods Clinical examination and comprehensive retinal imaging including spectral-domain optical coherence tomography (SD-OCT), near-infrared reflectance (NIR), and colour fundus photography at baseline and every follow-up visit. Main Outcome Measures Incidence of geographic atrophy (GA) and CNV in the fellow eye. Results Mean age was 77 (±7) years, and 61% of the cohort were female. 116 (58%) had RPD, 68% had drusen ≥125 μm, 36% pigmentary changes, 10% had both drusen ≥125 μm and pigmentary changes, and 17% had only RPD in their fellow eyes. After a mean follow-up of 2.3 years, 36% developed CNV and 14% GA. Those with RPD developed late-stage AMD more often (61% versus 33.4%, p<0.001), and more often GA (22.4% with RPD versus 2.4% without RPD, p<0.001). RPD was an independent risk factor for the development of GA (hazard ratio (HR) 4.93; p=0.042), but not for CNV (HR 1.19; p=0.500), at least within the follow-up of this study. Both drusen ≥125μm and pigmentary changes at baseline were a significant risk factor for the development of CNV and GA (HR 1.96 – 11.73; p ≤ 0.020). Conclusions RPD appear to confer an increased risk of progression to GA, additive to drusen and pigmentary changes. The presence of RPD needs to be taken into account when discussing a patient's prognosis and planning management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ophtha.2013.12.034

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 167

Metadata

Authors
Finger, R. P., Wu, Z., Luu, C. D., Kearney, F., Ayton, L. N., Lucci, L. M., Hubbard, W. C., Hageman, J. L., Hageman, G. S., & Guymer, R. H.
Venue
Ophthalmology
Publisher
Elsevier BV
Published
2014-06
Volume
121
Issue
6
Pages
1252-1256
ISSN
0161-6420 (ISSN-L)
OpenAlex
W183193446
Cited by
167
References
1
FWCI
15.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reticular Pseudodrusen. https://app.cochat.ai/papers/10.1016/j.ophtha.2013.12.034
The paper
Finger, R. P., Wu, Z., Luu, C. D., Kearney, F., Ayton, L. N., Lucci, L. M., Hubbard, W. C., Hageman, J. L., Hageman, G. S., & Guymer, R. H. (2014). Reticular Pseudodrusen. Ophthalmology. https://doi.org/10.1016/j.ophtha.2013.12.034

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.