Plus Disease in Retinopathy of Prematurity
Open accessThe DOI matches its Crossref record.
Abstract
Objective To determine expert agreement on relative retinopathy of prematurity (ROP) disease severity, whether computer-based image analysis can model relative disease severity, and to propose consideration of a more continuous severity score for ROP. Design We developed two databases of clinical images of varying disease severity (100 images and 34 images) as part of the i-ROP (Imaging and Informatics in ROP) cohort study and recruited both expert physician, non-expert physician, and non-physician graders to classify and perform pairwise comparisons on both databases. Subjects, Participants, and/or Controls Images obtained during routine ROP screening in neonatal intensive care units. 6 participating expert ROP clinician-scientists, each with a minimum of 10 years clinical ROP experience and 5 ROP publications. 5 image graders (3 physicians and 2 non-physician graders). Methods Images in both databases were ranked by average disease classification (classification ranking) and by pairwise comparison using the Elo rating method (comparison ranking), and correlation with the i-ROP computer-based image analysis system. Main Outcome Measures Inter-expert agreement (weighted kappa statistic) compared with correlation coefficient (CC) between experts on pairwise comparisons, and correlation between expert rankings and computer-based image analysis modeling. Results There was variable inter-expert agreement on diagnostic classification of disease (plus, pre-plus, or normal) among the 6 experts (mean weighted kappa 0.27, range 0.06–0.63), but good correlation between experts on comparison ranking of disease severity (mean CC 0.84, range 0.74–0.93) on the set of 34 images. Comparison ranking provided a severity ranking that was in good agreement with ranking obtained by classification ranking (CC 0.92). Comparison ranking on the larger dataset by both expert and non-expert graders demonstrated good correlation (mean CC 0.97, range 0.95–0.98). The i-ROP system was able to model this continuous severity with good correlation (CC 0.86). Conclusions Experts diagnose plus disease on a continuum with poor absolute agreement on classification, but good relative agreement on disease severity. These results suggest that the use of pairwise rankings and a continuous severity score, such as that provided by the i-ROP system, may improve agreement on disease severity in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brown, J. M., Campbell, J. P., Beers, A., Chang, K., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., et al. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2018.1934 · Cited by 657
Self-citationDigital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
Self-citationDeep learning in ophthalmology: The technical and clinical considerations
Ting, D. S. W., Peng, L., Varadarajan, A. V., Keane, P. A., Burlina, P. M., Chiang, M. F., Schmetterer, L., Pasquale, L. R., Bressler, N. M., Webster, D. R., et al. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.04.003 · Cited by 534
Self-citationAligning Large Language Models with Human: A Survey
Wang, Y., Zhong, W., Li, L., Mi, F., Zeng, X., Huang, W., Shang, L., Jiang, X., & Liu, Q. (2023) · arXiv · doi:10.48550/arxiv.2307.12966 · Cited by 69
Expert Discussions Improve Comprehension of Difficult Cases in Medical Image Assessment
Schaekermann, M., Cai, C. J., Huang, A. E., & Sayres, R. (2020) · Proceedings of the 2020 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3313831.3376290 · Cited by 28
Metadata
- Authors
- Kalpathy-Cramer, J., Campbell, J. P., Erdogmus, D., Tian, P., Kedarisetti, D., Moleta, C., Reynolds, J. D., Hutcheson, K., Shapiro, M. J., Repka, M. X., Ferrone, P., Drenser, K., Horowitz, J., Sonmez, K., Swan, R., Ostmo, S., Jonas, K. E., Chan, R. V. P., Chiang, M. F., Chiang, M. F., Ostmo, S., Sonmez, K., Campbell, J. P., Chan, R. V. P., Jonas, K., Horowitz, J., Coki, O., Eccles, C.-A., Sarna, L., Berrocal, A., Negron, C., Denser, K., Cumming, K., Osentoski, T., Check, T., Zajechowski, M., Lee, T., Kruger, E., McGovern, K., Simmons, C., Murthy, R., Galvis, S., Rotter, J., Chen, I., Li, X., Taylor, K., Roll, K., Kalpathy-Cramer, J., Erdogmus, D., Martinez-Castellanos, M. A., Salinas-Longoria, S., Romero, R., Arriola, A., Olguin-Manriquez, F., Meraz-Gutierrez, M., Dulanto-Reinoso, C. M., & Montero-Mendoza, C.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2016-11
- Volume
- 123
- Issue
- 11
- Pages
- 2345-2351
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2507467374
- Cited by
- 86
- References
- 0
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Plus Disease in Retinopathy of Prematurity. https://app.cochat.ai/papers/10.1016/j.ophtha.2016.07.020
- The paper
- Kalpathy-Cramer, J., Campbell, J. P., Erdogmus, D., Tian, P., Kedarisetti, D., Moleta, C., Reynolds, J. D., Hutcheson, K., Shapiro, M. J., Repka, M. X., Ferrone, P., Drenser, K., Horowitz, J., Sonmez, K., Swan, R., Ostmo, S., Jonas, K. E., Chan, R. V. P., Chiang, M. F., . . . Montero-Mendoza, C. (2016). Plus Disease in Retinopathy of Prematurity. Ophthalmology. https://doi.org/10.1016/j.ophtha.2016.07.020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.