Evidence-based Criteria for Assessment of Visual Field Reliability
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Objective Assess the impact of false positives (FPs), false negatives (FNs), fixation losses (FLs) and test duration (TD) on visual field (VF) reliability at different stages of glaucoma severity. Participants 10,262 VFs from 1,538 eyes of 909 subjects with suspect or manifest glaucoma and ≥5 VF examinations. Design Retrospective. Methods Predicted mean deviation (MD) was calculated with multilevel modeling of longitudinal data (>5 non-initial VFs). Differences between predicted and observed MD (ΔMD) were calculated as a reliability measure. The impact of FPs, FNs, FLs and TD on ΔMD was assessed using multi-level modelling. Main outcome measure ΔMD associated with a 10% increment in FPs, FNs, and FLs, or a 1-minute change in test duration. Results FLs had little impact on ΔMD (<0.2 dB per 10% abnormal catch trials) and no level of FL produced ≥ 1 dB of ΔMD at any disease stage. FPs yielded greater than expected MD, with a 10% increment in abnormal catch trials associated with a ΔMD=0.42, 0.73, and 0.66 dB in mild (MD>−6 dB), moderate (−6≤MD<−12 dB), and severe (−12≤MD≤−20 dB) disease, respectively, up to 20% abnormal catch trials, and a ΔMD=1.57, 2.06, and 3.53 dB beyond 20% abnormal catch trials. FNs generally produced observed MDs below expected MDs. FNs were minimally impactful up to 20% abnormal catch trials (ΔMD per 10% increment >−0.14 dB at all levels of severity). Beyond 20% abnormal catch trials, each 10% increment in abnormal FN catch trials was associated with a ΔMD=−1.27, −0.53, and −0.51 dB in mild, moderate and severe disease. |ΔMD|≥1dB occurred with 22% FPs and 26% FNs in early, 14% FPs and 34% FNs in moderate, and 16% FPs and 51% FNs in severe disease. A 1-minute increment in TD produced a ΔMD between −0.35 and −0.40 depending on disease severity. Conclusion FLs have little impact on test reliability in established glaucoma patients. FPs, and to a lesser extent FNs and test duration, impact reliability significantly. The impact of FP and FN varies with disease severity and over the range of abnormal catch trials. Based on our findings, we present evidence-based severity-specific standards for classifying VF reliability are presented for clinical or research applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M. A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.701 · Cited by 3,705
Heijl, A. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.10.1268 · Cited by 3,320 · cited 1×
“Although this study moved us toward a quantitative assessment of visual field reliability, it had several limitations including: (1) lack of a complete investigation of the relative impact of different measures at different stages of disease severity, (2) equal weighting of each additional 10% FPs, FNs, or FLs (thus s…”
Method(2000) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00538-9 · Cited by 2,780
(1975) · New England Journal of Medicine · doi:10.1056/nejm197507312930513 · Cited by 1,017
Musch, D. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)90147-1 · Cited by 402 · cited 2×
“Although this study moved us toward a quantitative assessment of visual field reliability, it had several limitations including: (1) lack of a complete investigation of the relative impact of different measures at different stages of disease severity, (2) equal weighting of each additional 10% FPs, FNs, or FLs (thus s…”
BackgroundMethodAssessment of the Reliability of Standard Automated Perimetry in Regions of Glaucomatous Damage
Gardiner, S. K., Swanson, W. H., Goren, D., Mansberger, S. L., & Demirel, S. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.020 · Cited by 212
Heijl, A., Bengtsson, B., Chauhan, B. C., Lieberman, M. F., Cunliffe, I. A., Hyman, L., & Leske, M. C. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.02.005 · Cited by 155
Self-citationMontolio, F. G. J., Wesselink, C., Gordijn, M. C. M., & Jansonius, N. M. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-10268 · Cited by 130
Visual Field Loss and Accelerometer-Measured Physical Activity in the United States
van Landingham, S. W., Willis, J. R., Vitale, S., & Ramulu, P. Y. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.06.034 · Cited by 103
Self-citationGlaucomatous Visual Field Loss Associated with Less Travel from Home
Ramulu, P. Y., Hochberg, C. H., Maul, E. A., Chan, E. S., Ferrucci, L., & Friedman, D. S. (2014) · Optometry and Vision Science · doi:10.1097/opx.0000000000000139 · Cited by 69
Self-citation
Cited by
Kihara, Y., Montesano, G., Chen, A., Amerasinghe, N., Dimitriou, C., Jacob, A., Chabi, A., Crabb, D. P., & Lee, A. Y. (2022) · Ophthalmology · doi:10.1016/j.ophtha.2022.02.017 · Cited by 62
Metadata
- Authors
- Yohannan, J., Wang, J., Brown, J., Chauhan, B. C., Boland, M. V., Friedman, D. S., & Ramulu, P. Y.
- Venue
- Ophthalmology
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 124
- Issue
- 11
- Pages
- 1612-1620
- ISSN
- 0161-6420 (ISSN-L)
- OpenAlex
- W2733018469
- Cited by
- 194
- References
- 12
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.